Part Number Hot Search : 
BYV27 C2501 80C196 2SC40 WM0834 2SC40 TB7100F 07K27
Product Description
Full Text Search
 

To Download FDC37N958FR Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 FDC37N958FR
Notebook I/O Controller with Enhanced Keyboard and System Control
FEATURES
! ! ! ! ! ! ! 5 Volt Operation ACPI 1.0 Compliant PC 99 Compliant Three Power Planes <20"A Consumption in Sleep Mode Configuration Register Set Compatible with ISA Plug-and-Play Standard (Version 1.0a) Serial IRQ meets IRQ Specification for PCI Systems - Quiet (Active) Mode - Continuous (Idle) Mode 8051 Controller uses Parallel Port to Reprogram the Flash ROM IR Interface Fully Compliant to IrDA 1.1 (Fast IR) - TEMIC/IBM Module Support - HP Module Support - Sharp Module Support ISA Host Interface - 16 Bit Address Qualification - 8 Bit Data bus - Zero Wait-State I/O Register Access - All Write Only Registers are Shadowed - IOCHRDY for ECP and Flash Cycles - 8 Direct IRQs Including nSMI - Four 8 Bit DMA Channels System Flash Interface (256Kx8) - 8051/Host CPU Multiplexed Interface - Eight 32K pages - 8051 Keyboard BIOS - Four 64K pages - Host System BIOS 8051 Keyboard and System Controller - Provides System Power Management - System Watch Dog Timer (WDT) - 8042 Style Host Interface Asynchronous Access to Two Data Registers and One Status Register - Supports Interrupt and Polling Access - 2K Internal ROM, nEA Pin Select - 32K Bank Switchable External Flash Rom Interface - 256 Bytes Data RAM - Access to On-Chip Control Registers via MOVX External Data Access Commands - Access to RTC and CMOS Registers - Up to 16x8 Keyboard Scan Matrix - Two 16 Bit Timer/Counter - Integrated TX/RX Serial Interface - Six 8051 Interrupt Sources - Sixteen 8 Bit, Host/8051 Mailbox Registers - 19 Maskable Hardware Wake-Up Events Supported - Fast GATEA20 - Fast CPU_RESET - Multiple Clock Sources and Frequencies - IDLE and SLEEP Modes Real Time Clock - MC146818 and DS1287 Compatible - 256 Bytes of Battery Backed CMOS in Two Banks of 128 Bytes - 128 Bytes of CMOS RAM Lockable in 4x32 Byte Blocks - 12 and 24 Hour Time Format - Binary and BCD Format - <1"A Standby Current (typ) ACCESS.bus Interface - 8584 Style Interface PS/2 Ports -
! !
!
!
!
!
! !
SMSC DS - FDC37N958FR
Rev. 09/01/99
!
! ! !
! !
- Four Independent Hardware Driven Ports General Purpose I/O - 22 I/O Pins - 12 Out Pins - 8 In Pins Two Pulse Width Modulators - Independent Clock Rates - 7 Bit Duty Cycle Granularity Intelligent Auto Power Management 2.88MB Super I/O Floppy Disk Controller - Relocatable to 480 Different Addresses - 13 IRQ Options - 4 DMA Options - Open Drain / Push-Pull Configurable Output Drivers - Licensed CMOS 765B Floppy Disk Controller - Advanced Digital Data Separator - Software and Register Compatible with SMSC's Proprietary 82077AA Compatible Core - Sophisticated Power Control Circuitry (PCC) Including Multiple Powerdown Modes for Reduced Power Consumption - Supports Two Floppy Drives Directly - 24 mA AT Bus Drivers - Low Power CMOS Design Floppy Disk Interface on Parallel Port Licensed CMOS 765B Floppy Disk Controller Core - Supports Vertical Recording Format - 16 Byte Data FIFO - 100% IBM(R) Compatibility - Detects All Overrun and Underrun Conditions - 48 mA Drivers and Schmitt Trigger Inputs - DMA Enable Logic - Data Rate and Drive Control Registers
!
!
!
Enhanced Digital Data Separator - Low Cost Implementation - No Filter Components Required - 2 Mbps, 1 Mbps, 500 Kbps, 300 Kbps, 250 Kbps Data Rates - Programmable Precompensation Modes Multi-Mode# Parallel Port with ChiProtect# - Relocatable to 480 Different Addresses - 13 IRQ Options - 4 DMA Options - Enhanced Mode - Standard Mode: (R) (R) - IBM PC/XT , PC/AT , and PS/2# Compatible Bidirectional Parallel Port - Enhanced Parallel Port (EPP) Compatible - EPP 1.7 and EPP 1.9 (IEEE 1284 Compliant) - High Speed Mode - Microsoft and Hewlett Packard Extended Capabilities Port (ECP) Compatible (IEEE 1284 Compliant) - Incorporates ChiProtect# Circuitry for Protection Against Damage Due to Printer Power-On - 12 mA Output Drivers Serial Ports - Relocatable to 480 Different Addresses - 13 IRQ Options - Two High Speed NS16C550A Compatible UARTs with Send/Receive 16 Byte FIFOs - Programmable Baud Rate Generator - Modem Control Circuitry Including 230K and 460K Baud - IrDA, HP-SIR, ASK-IR Support
IBM, PC/XT and PC/AT are registered trademarks and PS/2 is a trademark of International Business Machines Corporation. SMSC is a registered trademark and Ultra I/O, ChiProtect, and Multi-Mode are trademarks of Standard Microsystems Corporation
ORDERING INFORMATION
Order Number: FDC37N958FRTQFP 208 Pin QFP/TQFP Package Options
SMSC DS - FDC37N958FR
Rev. 09/01/99
TABLE OF CONTENTS GENERAL DESCRIPTION ...................................................................................................................... 1 PIN CONFIGURATION ............................................................................................................................ 2 DESCRIPTION OF PIN FUNCTIONS ...................................................................................................... 3 ALTERNATE FUNCTION PIN LIST ...................................................................................................... 10 BUFFER TYPE DESCRIPTIONS .......................................................................................................... 12 FUNCTIONAL DESCRIPTION............................................................................................................... 13 AUTO POWER MANAGEMENT............................................................................................................ 17 FLOPPY DISK CONTROLLER ............................................................................................................. 23 FDC INSTRUCTION SET ...................................................................................................................... 50 FDC DATA TRANSFER COMMANDS .................................................................................................. 62 FDC CONTROL COMMANDS ............................................................................................................... 71 COMPATIBILITY ................................................................................................................................... 77 SERIAL PORT (UART).......................................................................................................................... 80 REGISTER DESCRIPTION ................................................................................................................... 80 PROGRAMMABLE BAUD RATE GENERATOR .................................................................................. 89 FIFO INTERRUPT MODE OPERATION................................................................................................ 91 FIFO POLLED MODE OPERATION...................................................................................................... 91 NOTES ON SERIAL PORT FIFO MODE OPERATION ........................................................................ 96 INFRARED COMMUNICATIONS CONTROLLER (IRCC) .................................................................... 98 IRRX/IRTX PIN ENABLE....................................................................................................................... 99 IR REGISTERS - LOGICAL DEVICE 5 ............................................................................................... 100 IR DMA CHANNELS............................................................................................................................ 101
SMSC DS - FDC37N958FR
Rev. 09/01/99
IR IRQS................................................................................................................................................ 101 PARALLEL PORT ............................................................................................................................... 102 PARALLEL PORT INTERFACE MULTIPLEXOR ............................................................................... 124 HOST (LEGACY) PARALLEL PORT INTERFACE (FDC37N958FR STANDARD)............................ 125 PARALLEL PORT FDC INTERFACE ................................................................................................. 125 PARALLEL PORT - 8051 CONTROL (FDC37N958FR STANDARD) ................................................ 126 8051 EMBEDDED CONTROLLER...................................................................................................... 127 FEATURES.......................................................................................................................................... 127 8051 FUNCTIONAL OVERVIEW......................................................................................................... 127 8051 MEMORY MAP ........................................................................................................................... 131 8051 CONTROL REGISTERS............................................................................................................. 136 WATCH DOG TIMER........................................................................................................................... 151 SHARED FLASH INTERFACE............................................................................................................ 153 8051 SYSTEM POWER MANAGEMENT ............................................................................................ 158 KEYBOARD CONTROLLER ............................................................................................................... 168 MAILBOX REGISTER INTERFACE .................................................................................................... 181 PS/2 INTERFACE DESCRIPTION....................................................................................................... 184 ACCESS.BUS INTERFACE DESCRIPTION ....................................................................................... 185 LED CONTROLS ................................................................................................................................. 189 PULSE WIDTH MODULATORS .......................................................................................................... 190 REAL TIME CLOCK CMOS ACCESS................................................................................................. 190 8051 CONTROLLED PARALLEL PORT ............................................................................................ 193 8051 CONTROLLED IR PORT............................................................................................................ 196
SMSC DS - FDC37N958FR
Rev. 09/01/99
GENERAL PURPOSE I/O (GPIO) ....................................................................................................... 197 MULTIPLEXED PINS .......................................................................................................................... 203 REAL TIME CLOCK ............................................................................................................................ 209 VCC1 POR........................................................................................................................................... 211 INTERNAL REGISTERS ..................................................................................................................... 212 TIME CALENDAR AND ALARM ......................................................................................................... 213 UPDATE CYCLE ................................................................................................................................. 214 CONTROL AND STATUS REGISTERS .............................................................................................. 215 INTERRUPTS ...................................................................................................................................... 220 FREQUENCY DIVIDER ....................................................................................................................... 220 PERIODIC INTERRUPT SELECTION ................................................................................................. 220 POWER MANAGEMENT..................................................................................................................... 221 ACCESS.BUS...................................................................................................................................... 222 BACKGROUND ................................................................................................................................... 222 REGISTER DESCRIPTION ................................................................................................................. 223 PS/2 DEVICE INTERFACE.................................................................................................................. 229 PS/2 LOGIC OVERVIEW..................................................................................................................... 229 SERIAL INTERRUPTS ........................................................................................................................ 233 FDC37N958FR CONFIGURATION ..................................................................................................... 238 CONFIGURATION ELEMENTS........................................................................................................... 238 TYPICAL SEQUENCE OF CONFIGURATION OPERATION.............................................................. 239 CONFIGURATION REGISTERS ......................................................................................................... 241 OPEN MODE REGISTERS.................................................................................................................. 266
SMSC DS - FDC37N958FR
Rev. 09/01/99
ELECTRICAL SPECIFICATIONS........................................................................................................ 269 LOAD CAPACITANCE ........................................................................................................................ 274 TIMING DIAGRAMS ............................................................................................................................ 275 FUNCTIONAL REVISION ADDENDUM .............................................................................................. 308 FDC37N958FR ERRATA SHEET........................................................................................................ 309
SMSC DS - FDC37N958FR
Rev. 09/01/99
GENERAL DESCRIPTION
The FDC37N958FR is compliant with ACPI 1.0 and PC 97 and incorporates an 8051 based keyboard controller; a Flash Interface; four PS/2 ports; real-time clock; SMSC's true CMOS 765B FDC with advanced digital data separator and 16 byte data FIFO; two 16C550A compatible UARTs, the second UART contains a Synchronous Communications Engine to provide for IrDA Ver 1.1 (Fast IR) compliance; one Multi-Mode parallel TM port which includes ChiProtect circuitry plus EPP and ECP support; 8584 style Access Bus interface; Serial IRQ peripheral agent interface; General Purpose I/O; Two independent pulse width modulators; on-chip 24 mA AT bus drivers and two floppy direct drive support. The true CMOS 765B core provides 100% compatibility with IBM PC/XT and PC/AT architectures in addition to providing data overflow and underflow protection. The SMSC advanced digital data separator incorporates SMSC's patented data separator technology, allowing for ease of testing and use. Both on-chip UARTs are compatible with the NS16C550A. The parallel port is compatible with IBM PC/AT architecture, as well as EPP and ECP. The 8051 controller can also take control of the parallel port interface to provide remote diagnostics or "Flashing" of the Flash memory. The FDC37N958FR has three separate power planes which allows it to provide "instant on" and system power management functions. Additionally, the FDC37N958FR incorporates sophisticated power control circuitry (PCC). The PCC supports multiple low power down modes. The FDC37N958FR's configuration register set is compatible with the ISA Plug-and-Play Standard (Version 1.0a) and provides the functionality to support Windows '95. Through internal configuration registers, each of the FDC37N958FR's logical device's I/O address, DMA channel and IRQ channel may be programmed. There are 480 I/O address location options, 13 IRQ options, and 4 DMA channel options for each logical device. The FDC37N958FR does not require any external filter components and is, therefore, easy to use and offers lower system cost and reduced board area. The FDC37N958FR is software and register compatible with SMSC's proprietary 82077AA core.
SMSC DS - FDC37N958FR
Page 1
Rev. 09/01/99
PIN CONFIGURATION
VCC1_PWGD nRESET_OUT GND 32KHz_OUT 24MHz_OUT nPWR_LED PWRGD SLCT PE BUSY nACK PD7 PD6 PD5 PD4 VCC2 PD3 PD2 PD1 PD0 nSLCTIN nINIT nERROR nALF nSTB RXD1 TXD1 GND nDSR1 nRTS1 nCTS1 nDTR1 nDCD1 nRI1 GPIO15 GPIO14 GPIO8 GPIO9 VCC1 GPIO13 GPIO10 GPIO11 GPIO12 IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 VCC0 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 104 103 102 101 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 VCC2 CLOCKI OUT7 SIRQ PSBDAT PSBCLK nMEMWR nMEMRD nROMCS IOCHRDY TC DRQ1 nDACK1 DRQ0 nDACK0 GND SD7 SD6 SD5 SD4 SD3 VCC2 SD2 SD1 SD0 AEN nIOW nIOR nNOWS OUT4 OUT3 GND OUT2 OUT1 OUT0 SA15 SA14 SA13 SA12 SA11 SA10 SA9 SA8 SA7 SA6 SA5 SA4 SA3 SA2 SA1 SA0 GPIO21
XOSEL XTAL1 XTAL2 AGND FAD0 FAD1 FAD2 FAD3 FAD4 FAD5 GND FAD6 FAD7 FA8 FA9 FA10 FA11 FA12 FA13 VCC1 FA14 FA15 FA16 FA17 FALE nFRD nFWR GPIO0 GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 GPIO6 GPIO7 GND nEA MODE AB_DATA AB_CLK nBAT_LED nFDD_LED OUT11 OUT10 OUT9 OUT8 IRRX IRTX VCC2 GPIO17 GPIO18 GPIO19
FDC37N958FR
208 PIN PQFP/TQFP
SMSC DS - FDC37N958FR
GND OUT5 OUT6 DRVDEN0 DRVDEN1 nMTR0 GND nDS0 nDIR nSTEP nWDATA nWGATE nHDSEL nINDEX nTRK0 nWPROT nRDATA nDSKCHG MID_0 GPIO16 FPD KSO13 KSO12 KSO11 KSO10 KSO9 KSO8 KSO7 VCC2 KSO6 KSO5 KSO4 KSO3 KSO2 KSO1 KSO0 KSI7 KSI6 KSI5 KSI4 KSI3 KSI2 KSI1 KSI0 EMCLK EMDAT IMCLK IMDAT GND KBCLK KBDAT GPIO20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52
FIGURE 1 - FDC37N958FR PIN CONFIGURATION
Page 2
Rev. 09/01/99
DESCRIPTION OF PIN FUNCTIONS
PinPin PIN # 80:82, 84:88 54:69 96 79 95 91,93 202, 201 90, 92 207, 208 94 77 78 97 98 70 71 72 74 75 76 161:166, 168:169 170:175, 177:180 182 SD[0:7] SA[0:15] nROMCS AEN HOST (ISA) INTERFACE System Data Bus System Address Bus ROM Chip Select Address Enable (DMA master has bus control) I/O Channel Ready DMA Requests DMA Requests/GP Outputs VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC1 VCC1 VCC1 I/O24 I I I OD24 O24 O24 I I/IO8 I I I I I O24 O24 O24 O24 O24 OD24 I/O8 O8 O8 NAME DESCRIPTION SUPPLY VOLTAGE TYPE
IOCHRDY DRQ[0:1] DRQ[2:3]/ OUT[8:9] nDACK[0:1] DMA Acknowledge nDACK[2:3]/ DMA Acknowledge/GPIO 18,19 GPIO18, 19 TC Terminal Count nIOR I/O Read nIOW I/O Write nMEMRD Memory Read nMEMWR Memory Write IRQ6(FDC)/ Floppy Disk Interrupt Request/ OUT0 Generic Output 0 nIRQ8/ Active low Interrupt Request 8/ OUT1 Generic Output 1 IRQ7(PP)/ Parallel Port Interrupt Request/ OUT2 Generic Output 2 IRQ12(M)/ Mouse Interrupt Request/ OUT3 Generic Output 3 IRQ1(KB)/ Keyboard Interrupt Request/ OUT4 Generic Output 4 nNOWS No Wait State FLASH ROM/ MEMORY MAP INTERFACE FAD[7:0] Flash Address/Data[7:0] Bus FA[8:17] nFRD Flash Address[17:8] Flash Memory Read
SMSC DS - FDC37N958FR
Page 3
Rev. 09/01/99
DESCRIPTION OF PIN FUNCTIONS
PinPin PIN # 183 181 36:30, 28:22 NAME DESCRIPTION SUPPLY VOLTAGE TYPE
nFWR FALE KSO[0:13]
44:37 193 45 46 47 48 50 51 52
53
KSI[0:7] nEA EMCLK EMDAT IMCLK IMDAT KBCLK KBDAT PS2CLK/ 8051RX/ GPIO[20] PS2DAT/ 8051TX/ GPIO[21] SIRQ / IRQ3(UA1) PSBCLK PSBDAT
Flash Memory Write Flash Address latch Enable KEYBOARD Keyboard Scan Outputs(14*8 = 112) Configuring GPIO4 and GPIO5 as KSO14 and KSO15 yields a scan matrix of 16 x 8 = 128. Keyboard Scan Inputs External Access for 2K ROM EM Serial Clock EM Serial Data IM Serial Clk IM Serial Data KBD Serial Clock KBD Serial Data PS2 Serial Clock
VCC1 VCC1 VCC1
O8 O8 OD4
VCC1 VCC1 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2
ISP I
I/OD 24 I/OD 24 I/OD 24 I/OD 24 I/OD 24 I/OD 24 I/OD24
PS2 Serial Data
VCC2
I/OD24
101 99 100
SERIAL IRQ / UART IRQS Serial Interrupt UART1 Interrupt PCI Clock input UART2 Interrupt
VCC2 VCC2 VCC2
I/O24 /O24 I I/O24 /O24
FDD INTERFACE The following FDC output pins can be configured as either Open Drain outputs capable of sinking 24mA (OD24) or as push-pull outputs capable of driving 12mA and sinking 24mA (O24). The FDC output pins must tristate when the FDC is in powerdown mode (The board designer must provide external pull-up resistors on these output pins). 17 nRDATA Read Disk Data VCC2 IS 12 nWGATE Write Gate VCC2 O24/ OD24 11 nWDATA Write Disk Data VCC2 O24/ OD24
SMSC DS - FDC37N958FR
Page 4
Rev. 09/01/99
DESCRIPTION OF PIN FUNCTIONS
PinPin PIN # 13 9 10 18 8 6 2 NAME DESCRIPTION SUPPLY VOLTAGE TYPE
nHDSEL nDIR nSTEP nDSKCHG nDS0 nMTR0 nDS1/ OUT5 nMTR1/ OUT6 nWPROT nTRK0 nINDEX DRVDEN[0:1] MID[0]
Head Select (1 = side 0 ) Step Direction (1 = out ) Step Pulse Disk Change Drive Select 0 Motor On 0 Drive Select 1/ Output 5 Motor On 1/ Output 6 Write Protected Track 0 Index Pulse Input Drive Density Select [0:1] Media ID 0 input. In floppy enhanced mode 2 this input is the media ID [0] input. Media ID 1 input. In floppy enhanced mode 2 this input is the media ID [1] input. General Purpose I/O Floppy Power Down output control. This is the output of three power down modes of the floppy (3F4, auto-power down, configuration). SERIAL PORT 1 INTERFACE Receive Serial Data 1 Transmit Serial Data 1 Request to Send 1 Clear to Send 1 Data Terminal Ready 1
VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2
3
VCC2
16 15 14 4:5 19
VCC2 VCC2 VCC2 VCC2 VCC2
O24/ OD24 O24/ OD24 O24/ OD24 IS O24 / OD24 O24 / OD24 O24 / OD24/ O24 O24 / OD24 O24 IS IS IS O24 / OD24 IS
20
MID[1]/ GPIO16
VCC2
IS I/O8
21
FPD
VCC2
O8
130 131 134 135 136
RXD1 TXD1 nRTS1 nCTS1 nDTR1
VCC2 VCC2 VCC2 VCC2 VCC2
I O4 O4 I O4
SMSC DS - FDC37N958FR
Page 5
Rev. 09/01/99
DESCRIPTION OF PIN FUNCTIONS
PinPin PIN # 133 137 138 141 142 145 146 147 144 140 139 NAME DESCRIPTION SUPPLY VOLTAGE TYPE
nDSR1 nDCD1 nRI1 RXD2/ GPIO8 TXD2/ GPIO9 nRTS2/ GPIO10 nCTS2/ GPIO11 nDTR2/ GPIO12 nDSR2/ GPIO13 nDCD2/ GPIO14 nRI2 / GPIO15 PD[0:7] nSLCTIN nINIT nALF nSTB BUSY nACK PE SLCT nERROR
124:121, 119:116 125 126 128 129 114 115 113 112 127
Data Set Ready 1 Data Carrier Detect 1 Ring Indicator 1 SERIAL PORT 2 INTERFACE Receive Serial Data 2/ General Purpose I/O 8 Transmit Serial Data 2/ General Purpose I/O 9 Request to Send 2/ General Purpose I/O 10 Clear to Send 2/ General Purpose I/O 11 Data Terminal Ready 2/ General Purpose I/O 12 Data Set Ready 2/ General Purpose I/O 13 Data Carrier Detect 2/ General Purpose I/O 14 Ring Indicator 2/ General Purpose I/O 15 PARALLEL PORT INTERFACE Parallel Port Data Bus Printer Select Initiate Output Auto Line Feed Strobe Signal Busy Signal Acknowledge Handshake Paper End Printer Selected Error at Printer RTC
VCC2 VCC2 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1
I I I I/ I/O8 O8/ I/O8 O8/ I/O8 I/ I/O8 O8/ I/O8 I/ I/O8 I/ I/O8 I/ I/O8 I/O24 OD24/ O24 OD24/ O24 OD24/ O24 OD24/ O24 I I I I I
VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2 VCC2
SMSC DS - FDC37N958FR
Page 6
Rev. 09/01/99
DESCRIPTION OF PIN FUNCTIONS
PinPin PIN # 158 159 102 108 NAME DESCRIPTION SUPPLY VOLTAGE TYPE
XTAL1 XTAL2 nSMI/ OUT7 32 KHz_OUT
109
24 MHz_OUT
103 195 196 194 157
CLOCKI AB_DATA AB_CLK MODE XOSEL
203 204 200 199
IRRX IRTX PWM0/ OUT10 PWM1/ OUT11
32 KHz Crystal Input 32 KHz Crystal Output MISCELLANEOUS System Management Interrupt/ Output 7 32 KHz Out -- The 32 KHz output is enabled / disabled by setting / clearing bit-0 of the Output Enable 8051 memory mapped register. When disabled the 32 KHz_OUT pin is driven low. The 32 KHz_OUT pin defaults to the disabled state on VCC1 POR. Programmable Clock Output. 1.8432 MHz (default = 24 MHz/13) 14.318 MHz 16 MHz 24 MHz 48 MHz 14.318 MHz Clock Input ACCESS.bus Serial Data ACCESS.bus Clock Set Configuration register address Test Mode Enable Input Pin. XOSEL = 1 is required to qualify all pin defined test modes. XOSEL = 0 prevents the pin test modes from ever being invoked. Infared Receive Infared Transmit Pulse Width Modulator 0/ Output 10 Pulse Width Modulator 1/ Output 11
VCC0 VCC0 VCC2 VCC1
ICLK2
OCLK2
O24 O8
VCC2
O24
VCC2 VCC1 VCC1 VCC1 VCC1
ICLK I/OD8 I/OD8 I I
VCC2 VCC2 VCC2 VCC2
I O8 O24 O24
SMSC DS - FDC37N958FR
Page 7
Rev. 09/01/99
DESCRIPTION OF PIN FUNCTIONS
PinPin PIN # 105 NAME DESCRIPTION SUPPLY VOLTAGE TYPE
VCC1_PWGD
106 197 110 198
nRESET_OUT nBAT_LED nPWR_LED nFDD_LED
111 148 149 150 151 152 153 154 155 184 185 186 187
PWRGD WK_EE4/IN0 WK_EE2/IN1 WK_EE3/IN2 nGPWKUP/ IN3 WK_HL1/IN4 WK_HL2/IN5 WK_HL6/IN6 WK_EE1/IN7 WK_HL3/ GPIO0 WK_HL4/ GPIO1 WK_HL5/ GPIO2 TRIGGER/ GPIO3
VCC1 Power Good Input pin. The trailing edge of VCC1 POR is released 20ms from the assertion of this pin. If this pin is pulled low while VCC1 is valid, then VCC1 POR will be asserted and held until 20ms from re-assertion of this pin. This pin has an internal weak (90"A) pull-up to VCC1. System reset (active low) Battery LED (0=on) Power LED (0=on) Floppy LED. This pin is asserted whenever either DRVSEL1 or DRVSEL0 is asserted or controlled by the 8051. (0 = on) Powergood Wakeup event/Generic Input 0 Wakeup event/Generic Input 1 Wakeup event/Generic Input 2 Wakeup event/Generic Input 3 Wakeup event/Generic Input 4 Wakeup event/Generic Input 5 Wakeup event/Generic Input 6 Wakeup event/Generic Input 7 Wakeup event/ GP I/O 0 Wakeup event/ GP I/O 1 Wakeup event/ GP I/O 2 Interrupt 1 event/ GP I/O 3
VCC1
I
VCC2 VCC1 VCC1 VCC1
O8 OD24 OD24 OD24
VCC2 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1
I I I I I I I I I I/ I/O8 I/ I/O8 I/ I/O8 I/ I/O8
SMSC DS - FDC37N958FR
Page 8
Rev. 09/01/99
Table 1 - Power Pin List Bias Pins 156 143,176 29,83,104, 120,205 160 1, 7, 49, 73, 89, Note: 107, 132, 167, 192 AB = ACCESS.bus AGND GND Analog Ground for VCC0. Ground VCC0 VCC1 VCC2 RTC Supply Voltage 8051 + AB +4.7V Supply Voltage (Note) Core +5V Supply Voltage
SMSC DS - FDC37N958FR
Page 9
Rev. 09/01/99
ALTERNATE FUNCTION PIN LIST
Table 2 - Alternate Function Pin List
Function Pin Number 70 71 72 74 75 2 3 102 202 201 200 199 148 149 150 151 152 153 154 155 184 185 186 187 Default OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUT10 OUT11 IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 GPIO0 GPIO1 GPIO2 GPIO3 Alternate IRQ6 (FDC) nIRQ8 IRQ7 (PP) IRQ12(Mouse) IRQ1(KBD) nDS1 nMTR1 nSMI DRQ2 (note1) | CPU_RESET DRQ3 (note1) PWM0 PWM1 WK_EE4 WK_EE2 WK_EE3 nGPWKUP WK_HL1 WK_HL2 WK_HL6 WK_EE1 WK_HL3 WK_HL4 WK_HL5 TRIGGER I/O Type Mux Default O24 O24 O24 O24 O24 O24 O24 O24 O24 O24 O24 O24 I I I I I I I I I/O8 I/O8 I/O8 I/O8 Alternate O24 O24 O24 O24 O24 O24/OD24 O24/OD24 O24 O24 O24 O24 O24 I I I I I I I I I I I I Control MISC0 VCC Plane VCC2
MISC5 MISC0 MISC10 + MISC6 MISC11 MISC4 alternate input masked by wake-up mask Register bits VCC1
VCC1
188 189 190 191 141 142 145 146 147 144 140
GPIO4 GPIO5 GPIO6 GPIO7 GPIO8 GPIO9 GPIO10 GPIO11 GPIO12 GPIO13 GPIO14
KSO14 KSO15 IR_MODE | FRX COM-RX COM-TX nRTS2 | IR_MODE | FRX nCTS2 nDTR2 nDSR2 nDCD2
I/O8 I/O8 I/O8 I/O8 I/O8 I/O8 I/O8 I/O8 I/O8 I/O8 I/O8
OD8 OD8 O8 | I I O8 (note2) O8 | O8 | I (note1) I O8 (note2) I I
Masked by INT1 mask register bit 3 MISC9
MISC[14:13] MISC7 MISC[16:15] MISC12
SMSC DS - FDC37N958FR
Page 10
Rev. 09/01/99
Function Pin Number 139 20 206 207 208 52 53 101 23 22 Default GPIO15 GPIO16 GPIO17 GPIO18 GPIO19 GPIO20 GPIO21 SIRQ KSO12 KSO13 Alternate nRI2 MID1 GATEA20 nDACK2 (note1) nDACK3 (note1) PS2CLK | 8051RX PS2DAT | 8051TX IRQ3 (UA1) OUT8 GPIO18
I/O Type Mux Default I/O8 IS/O8 I/O8 I/O8 I/O8 I/OD24 I/OD24 O8 OD4 OD4 Alternate I IS O8 I I I/OD24 | I I/OD24 | OD24 O8 OD4 OD4 Control MISC8 MISC6 MISC17 MISC11 MISC1 + MISC3 MISC0 MISC17 + 6 MISC17 VCC Plane VCC2
VCC1
Note 1: With the inclusion of Fast IR two additional DMA channels are provided. Note 2: When GPIO6, GPIO9, GPIO10 and/or GPIO12 are configured as IR_MODE, COMTX, nRTS2|IR_MODE, and/or nDTR2 respectively and POWERGOOD=0 (VCC2 low) then these pins will tri-state to prevent back-biasing of external circuitry. The Mux Control Column in Table 2 lists the Misc Bits which the 8051 has access to through the three Multiplexing registers. See the 8051 section of this data sheet for a description of the Multiplexing registers.
SMSC DS - FDC37N958FR
Page 11
Rev. 09/01/99
BUFFER TYPE DESCRIPTIONS
I IS ISP ICLK ICLK2 OCLK2 O4 O8 OD8 O8SR O16 OD16 O24 OD24 OD48 Input, TTL compatible. Input with Schmitt trigger Input with Schmitt trigger, 90uA pull-up. Input to crystal oscillator circuit (CMOS levels) Crystal input Output to external crystal Output, 4mA sink, 2mA source. Output, 8mA sink, 4mA source. Open Drain Output, 8mA sink. Output, 8mA sink, 4mA source with Slew Rate Limiting Output, 16mA sink, 8mA source. Open Drain Output, 16mA sink. Output, 24mA sink, 12mA source. Open Drain Output, 24mA sink. Open Drain Output, 48mA sink
SMSC DS - FDC37N958FR
Page 12
Rev. 09/01/99
FUNCTIONAL DESCRIPTION
VCC1 (2) VCC2 (5) GND (9)
nRESET_OUT
SYSTEM RESET
nIOR WDATA nIOW nMEMRD nMEMWR nROMCS AEN SA[0:15] SD[0:7] DRQ[0:1] DRQ[2:3]*2 nDACK[0:1] TC nDACK[2:3]*1 IRQ4 IRQ[1,6-8,12] (*2) IRQ[3] (*3), nSMI (*2) nNOWS IOCHRDY MODE nEA VCC1_PWGD PWRGOOD
DIGITAL DATA SEPARATOR WITH WRITE PRECOMPENSATION RCLOCK WCLOCK RDATA
nWDATA 16C550 nRDATA, COMPATIBLE SERIAL PORT 1 TXD1, nRTS1, nDTR1 RXD1, nCTS1, nDSR1, nDCD1 nRI1 nDSKCHG, nWPROT, nTRK0, nINDEX, MID0, MID1(*1) nWGATE, nHDSEL, nDIR, nSTEP, nDS0, nDS1 (*2), nMTR0, nMRT1 (*2), DRVDEN0, DRVDEN1 (*2), FPD
CONTROL ADDRESS DATA
SMSC PROPRIETARY 82077 COMPATIBLE VERTICAL FLOPPY DISK CONTROLLER CORE
16C550 COMPATIBLE SERIAL PORT 2 WITH INFRARED
TXD2(*1), nRTS2(*1), nDTR2 (*1) RXD2(*1), nCTS2(*1), nDSR2(*1), nDCD2(*1), nRI2 (*1) IRTX IRRX PD[0:7]
HOST CPU INTERFACE
CONTROL ADDRESS DATA
MULTI-MODE PARALLEL PORT / FDC MUX
BUSY, SLCT, PE, nERROR, nACK nSTB, nSLCTIN, nINIT, nALF SIRQ PSBCLK PSBDAT IN IN0 - 7 OUT0 - 11 GPIO16 - 21 GPIO0 - 15 nBAT_LED, nPWR_LED, nFDD_LED KSI[0:7] KS0[0:13] , KS0[14:15](*2)
SIRQ/PSB INTERFACE CONFIGURATION REGISTERS POWER MANAGEMENT GENERAL PURPOSE I/O INTERFACE
OUT I/O I/O
CONTROL ADDRESS DATA
CONTROL ADDRESS DATA
LED DRIVER 16 x 8 MATRIX KEYBOARD INTERFACE
CONTROL INPUTS
MAILBOX REGISTERS
8051
32KHz_OUT 24MHz_OUT CLOCKI (14.318 MHz) XOSEL XTAL2 XTAL1 VCC0 AGND BANK 1 BANK 2 RTC two 128B banks of CMOS RAM PLL CLOCK GENERATOR
WDT
256B Direct RAM
8051 SUB-BLOCK EXTERNAL CONTROL REGISTERS 256B External 8051 RAM
PS/2 PORTS
EMCLK, EMDAT, IMCLK, IMDAT KBCLK, KBDAT, PS2CLK(*1), PS2DAT(*1)
ACCESS BUS
AB_DATA, AB_CLK
PWM
PWM0 (*2), PWM1 (*2) FAD[0:7] FA[8:17], nFRD, nFWR, FALE
Ring Oscillator
28F020 (2Mbit) FLASH INTERFACE
*1 -- GPIO pin multiplexed option *2 -- OUT pin multiplexed option *3 -- Muxed with SIRQ and PSBDATA pins
VCC2 POWERED CIRCUITRY VCC1 POWERED CIRCUITRY
FIGURE 2 - FUNCTIONAL BLOCK DIAGRAM
SMSC DS - FDC37N958FR
Page 13
Rev. 09/01/99
FDC37N958FR OPERATING REGISTERS The address map, shown below in Table 3, shows the set of operating registers and addresses for each of the logical blocks of the FDC37N958FR Ultra I/O controller. The base addresses of the FDC, Parallel, Serial 1 and Serial 2 ports can be moved via the configuration registers.
HOST PROCESSOR INTERFACE The host processor communicates with the FDC37N958FR through a series of read/write registers. The range of base I/O port addresses for these registers is shown in Table 3. Register access is accomplished through programmed I/O or DMA transfers. All registers are 8 bits. Most of the registers support zero wait-state access (NOWS). All host interface output buffers are capable of sinking a minimum of 12 mA.
LOGICAL DEVICE NUMBER 0x00
0x03
Table 3 - FDC37N958FR Operating Register Addresses BASE I/O LOGICAL RANGE FIXED DEVICE (NOTE3) BASE OFFSETS +0 : SRA FDC [0x100:0x0FF8] +1 : SRB ON 8 BYTE +2 : DOR BOUNDARIES +3 : TSR +4 : MSR/DSR +5 : FIFO +7 : DIR/CCR Parallel [0x100:0x0FFC] +0 : Data / ecpAfifo Port ON 4 BYTE +1 : Status BOUNDARIES +2 : Control (EPP Not +400h : cfifo / ecpDfifo supported) tfifo / cnfgA or +401h : cnfgB [0x100:0x0FF8] +402h : ecr ON 8 BYTE BOUNDARIES (all modes supported, EPP is only available when the base address is on an 8-byte boundary)
ISA CYCLE TYPE NOWS
Std. ISA I/O
SMSC DS - FDC37N958FR
Page 14
Rev. 09/01/99
LOGICAL DEVICE NUMBER 0x04
LOGICAL DEVICE Serial Port 1
BASE I/O RANGE (NOTE3) [0x100:0x0FF8] ON 8 BYTE BOUNDARIES
0x05
Serial Port 2
[0x100:0x0FF8] ON 8 BYTE BOUNDARIES
0x62, 0x63
[0x100:0x0FF8] ON 8 BYTE BOUNDARIES
0x06
RTC
Not Relocatable Fixed Base Address
FIXED BASE OFFSETS +0 : RB/TB $ LSB div +1 : IER % MSB div +2 : IIR/FCR +3 : LCR +4 : MCR +5 : LSR +6 : MSR +7 : SCR +0 : RB/TB $ LSB div +1 : IER % MSB div +2 : IIR/FCR +3 : LCR +4 : MCR +5 : LSR +6 : MSR +7 : SCR +0 : Register Block N, address 0 +1 : Register Block N, address 1 +2 : Register Block N, address 2 +3 : Register Block N, address 3 +4 : Register Block N, address 4 +5 : Register Block N, address 5 +6 : Register Block N, address 6 +7 : USRT Master Control Reg. 0x70, 0x74 : Address Register 0x71, 0x76 : Data Register
ISA CYCLE TYPE NOWS
NOWS
NOWS Std. ISA I/O
SMSC DS - FDC37N958FR
Page 15
Rev. 09/01/99
LOGICAL DEVICE NUMBER 0x07
LOGICAL DEVICE KYBD
BASE I/O RANGE (NOTE3) Not Relocatable Fixed Base Address
FIXED BASE OFFSETS 0x60 : Data Register 0x64 : Command/Status Reg.
ISA CYCLE TYPE NOWS
Note 1: Refer to the configuration register descriptions for setting the base address Note 2: Serial Port 2 supports Infrared. Note 3: This chip uses all ISA address bits to decode the base address of each of its logical devices.
SMSC DS - FDC37N958FR
Page 16
Rev. 09/01/99
AUTO POWER MANAGEMENT
Auto Power Management (APM) capabilities are provided for the following logical devices: Floppy Disk, UART 1, UART 2 and the Parallel Port. For each logical device, two types of power management are provided; direct powerdown and auto powerdown. System Power Management See the "8051 System Power Management" section for details. FDC Power Management Direct power management is controlled through Global Configuration Register 22 (CR22). Refer to CR22 in the Configuration section for more information. Auto Power Management is enabled through bit-0 of CR23. When set, this bit allows the FDC to enter powerdown when all of the following conditions have been met: 1. 2. The motor enable pins of the FDC's DOR register are inactive (zero). The FDC37N958FR must be idle; the MSR register = 80h and the FDC's INTerrupt = 0 (INT may be high even if MSR = 80H due to polling interrupts). The head unload timer must have expired. The Auto powerdown timer (10msec) must have timed out. Disabling the auto powerdown mode cancels the timer and holds the FDC block out of auto powerdown. DSR From Powerdown Bit 6 of the FDC's DSR register is another FDC powerdown bit. If DSR powerdown is used when the FDC37N958FR is in auto powerdown, the DSR powerdown will override the auto powerdown. However, when the FDC37N958FR is awakened from DSR powerdown, the auto powerdown will once again become effective. Wake Up From Auto Powerdown If the FDC37N958FR enters the powerdown state through the auto powerdown mode, then the FDC37N958FR can be awakened by reset or by appropriate access to certain registers. If a hardware or software reset is used then the FDC37N958FR will go through the normal reset sequence. If the access is through the selected registers, then the FDC resumes operation as though it was never in powerdown. Besides activating the RESET pin or one of the software reset bits in the DOR or DSR registers, the following register accesses will wake up the FDC37N958FR: 1. 2. 3. Enabling any one of the motor enable bits in the DOR register (reading the DOR does not awaken the FDC37N958FR). A read from the MSR register. A read or write to the Data register.
3. 4.
An internal timer is initiated as soon as the auto powerdown command is enabled. The FDC37N958FR is then powered down when all the conditions are met.
Once awake, the FDC will reinitiate the auto powerdown timer for 10 ms. The FDC37N958FR will powerdown again when all the powerdown conditions are satisfied.
SMSC DS - FDC37N958FR
Page 17
Rev. 09/01/99
Register Behavior Table 4 shows the AT and PS/2 (including Model 30) configuration registers available. It also shows the type of access permitted. In order to maintain software transparency, access to all the registers is maintained. As Table 4 shows, two sets of registers are distinguished based on whether their access results in the FDC37N958FR remaining in powerdown state or exiting it. Access to all other registers is possible without awakening the FDC37N958FR. These registers can be accessed during powerdown without changing the status of the FDC37N958FR. A read from these registers will reflect the true status as shown in the register description in the FDC section. Writes to these registers will result in the FDC37N958FR retaining the data and subsequently reflecting it when the FDC37N958FR awakens. Accessing the
FDC37N958FR during powerdown may cause an increase in the power consumption by the FDC37N958FR. The FDC37N958FR will revert back to its low power mode when the access has been completed. Pin Behavior The FDC37N958FR is specifically designed for portable PC systems in which power conservation is a primary concern. This makes the behavior of the pins during powerdown very important. The pins which interface to the floppy disk drive are disabled so that no power will be drawn through the FDC37N958FR as a result of any voltage applied to the pin within the VCC2 power supply range. Most of the pins which interface to the system are left active to monitor system accesses that may wake up the FDC37N958FR.
SMSC DS - FDC37N958FR
Page 18
Rev. 09/01/99
System Interface Pins Table 5 gives the state of the system interface pins in the powerdown state. Pins unaffected by
the powerdown are labeled "Unchanged". Input pins are "Disabled" to prevent them from causing currents internal to the FDC37N958FR when they have indeterminate input values.
Table 4 - PC/AT and PS/2 Available Registers BASE + ADDRESS AVAILABLE REGISTERS PC/AT 00H 01H 02H 03H 04H 06H 07H 07H 04H 05H ------DOR (1) --DSR (1) --DIR CCR MSR Data PS/2 (Model 30) SRA SRB DOR (1) --DSR (1) --DIR CCR MSR Data R R R/W --W --R W R R/W ACCESS PERMITTED
Access to these registers DOES NOT wake up the FDC37N958FR
Access to these registers wakes up the FDC37N958FR
Note 1: Writing to the DOR or DSR does not wake up the FDC37N958FR, however, writing any of the motor enable bits or doing a software reset (via DOR or DSR reset bits) will wake up the FDC37N958FR.
SMSC DS - FDC37N958FR
Page 19
Rev. 09/01/99
Table 5 - State of System Pins in FDC Auto Powerdown SYSTEM PINS STATE IN AUTO POWERDOWN Input Pins nIOR nIOW AEN nMEMRD nMEMWR SA[15:0] SD[7:0] nNOWS nDACKx TC nROMCS RESET_OUT IRQx DB[0:7] DRQx IOCHRDY FDD Interface Pins All pins in the FDD interface which can be connected directly to the floppy disk drive itself are either DISABLED or TRISTATED. Pins used for local logic control or part programming are unaffected. Table 6 depicts the state of the floppy disk drive interface pins in the powerdown state. FDD Power Down Pin (FPD) Behavior The FPD pin can be used to automatically shut off power to the floppy disk drive when it is not required. The FPD pin is an active high output signal which is driven based on the states of the Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged(hi-Z) Unchanged Unchanged Unchanged Output Pins Unchanged Unchanged(low) Unchanged Unchanged(low) Unchange(n/a) FDC. Whenever the FDC Shutdown bit is set (see FDD Mode Register, bit-5 in the Configuration Register Section) the FPD pin goes high. If the FDC Shutdown bit is not set then the FPD pin will go high whenever the FDC bit (see bit 0 of the Power Mgmt Register in the Configuration Section) is set and the FDC has entered an auto powerdown state as described above. If neither the FDC Shutdown bit nor the FDC bit are set then the FPD pin goes active "high" when the Power- down bit is set (see bit 6 of the Data Rate Select Register [DSR]) and "low" when the Powerdown bit is cleared. Refer to Table 6A.
SMSC DS - FDC37N958FR
Page 20
Rev. 09/01/99
Table 6 - State of Floppy Disk Drive Interface pins in FDC Powerdown STATE IN FDC AUTO FDD PINS POWERDOWN Input Pins nRDATA nWPROT nTRK0 nINDEX nDSKCHG Output Pins nMTR[1:0] nDS[1:0] nDIR nSTEP nWDATA WGATE nHDSEL DRVDEN[1:0] FPD Tristated Tristated Active Active Tristated Tristated Active Active Active Input Input Input Input Input
Table 6A - FPD Pin Behavior POWER DOWN BIT, FDC BIT, GCR23 BIT-0 FDC SHUTDOWN BIT, FPD PIN DSR, BIT-6 AUTO POWER DOWN FDD MODE REGISTER STATE 0 0 0 0 1 0 0 1 X 1 0 1 (Note) X X 1 1 Note: The FPD pin will go active when the FDC auto powers down. Refer to the FDC auto power management section for more details.
SMSC DS - FDC37N958FR
Page 21
Rev. 09/01/99
UART Power Management Direct power management is controlled by CR22. Refer to CR22 in the Configuration Section for more information. Auto power management is enabled by CR23 bit 4 and bit 5. When set, these bits allow the following auto power management operations: 1. 2. The transmitter enters auto powerdown when the transmit buffer and shift register are empty. The receiver enters powerdown when the following conditions are all met: A. B. Note: Receive FIFO is empty The receiver is waiting for a start bit. While in powerdown the Ring Indicator interrupt is still valid.
Parallel Port Power Management Direct power management is controlled by CR22. Refer to CR22 in the Configuration Section for more information. Auto power management is enabled by CR23 bit 3. When set, this bit allows the ECP or EPP logical parallel port blocks to be placed into powerdown when not being used. The EPP logic is in powerdown under any of the following conditions: 1. 2. EPP is not enabled in the configuration registers. EPP is not selected through ecr while in ECP mode.
The ECP logic is in powerdown under any of the following conditions: 1. 2 ECP is not enabled in the configuration registers. SPP, PS/2 Parallel port or EPP mode is selected through ecr while in ECP mode.
Exit Auto Powerdown The transmitter exits powerdown on a write to the transmit buffer. The receiver exits auto powerdown when RXD changes state.
Exit Auto Powerdown The parallel port logic can change powerdown modes when the ECP mode is changed through the ecr register or when the parallel port mode is changed through the configuration registers.
SMSC DS - FDC37N958FR
Page 22
Rev. 09/01/99
FLOPPY DISK CONTROLLER
The Floppy Disk Controller (FDC) provides the interface between a host microprocessor and the Floppy Disk Drives (FDD). The FDC integrates the functions of the formatter/controller, Digital Data Separator, Write Precompensation and data rate Selection logic for an IBM XT/AT compatible FDC. The true CMOS 765B core guarantees 100% IBM PC XT/AT compatibility in addition to providing data overflow and underflow protection. The FDC is compatible to the 82077AA using SMSC's proprietary FDC core. FDC INTERNAL REGISTERS The FDC contains eight internal registers which facilitate the interfacing between the host microprocessor and the disk drive. shows the addresses required to access these registers. Registers other than the ones shown are not supported.
Table 7 - Status, Data and Control Registers FDC PRIMARY BASE I/O ADDRESS OFFSET R/W REGISTER 0 R Status Register A (SRA) 1 R Status Register B (SRB) 2 R/W Digital Output Register (DOR) 3 R/W Tape Drive Register (TDR) 4 R Main Status Register (MSR) 4 W Data Rate Select Register (DSR) 5 R/W Data (FIFO) 6 Reserved 7 R Digital Input Register (DIR) 7 W Configuration Control Register (CCR)
SMSC DS - FDC37N958FR
Page 23
Rev. 09/01/99
STATUS REGISTER A (SRA) FDC I/O Base Address + 0x00 (READ ONLY) This register is read-only and monitors the state of the FDC Interrupt pin and several disk interface
pins in PS/2 and Model 30 modes. The SRA can be accessed at any time when in PS/2 mode. In the PC/AT mode the data bus pins D0 - D7 are held in a high impedance state for a read of SRA.
SRA - PS/2 Mode 7 INT PENDING 0 6 nDRV2 N/A 5 STEP 0 4 3 2 nTRK0 HDSEL nINDX N/A 0 N/A 1 nWP N/A 0 DIR 0
RESET COND.
BIT 0 DIRECTION Active high status indicating the direction of head movement. A logic "1" indicates inward direction; a logic "0" indicates outward direction. BIT 1 nWRITE PROTECT Active low status of the WRITE PROTECT disk interface input. A logic "0" indicates that the disk is write protected. BIT 2 nINDEX Active low status of the INDEX disk interface input. BIT 3 HEAD SELECT Active high status of the HDSEL disk interface input. A logic "1" selects side 1 and a logic "0" selects side 0.
BIT 4 nTRACK 0 Active low status of the TRK0 disk interface input. BIT 5 STEP Active high status of the STEP output disk interface output pin. BIT 6 nDRV2 Active low status of the DRV2 disk interface input pin, indicating that a second drive has been installed. BIT 7 INTERRUPT PENDING Active high bit indicating the state of the Floppy Disk Interrupt output.
SMSC DS - FDC37N958FR
Page 24
Rev. 09/01/99
SRA - PS/2 Model 30 Mode 7 INT PENDING 0 6 DRQ 0 5 STEP F/F 0 4 TRK0 N/A 3 nHDSEL 1 2 INDX N/A 1 WP N/A 0 nDIR 1
RESET COND.
BIT 0 nDIRECTION Active low status indicating the direction of head movement. A logic "0" indicates inward direction; a logic "1" indicates outward direction. BIT 1 WRITE PROTECT Active high status of the WRITE PROTECT disk interface input. A logic "1" indicates that the disk is write protected. BIT 2 INDEX Active high status of the INDEX disk interface input. BIT 3 nHEAD SELECT Active low status of the HDSEL disk interface input. A logic "0" selects side 1 and a logic "1" selects side 0.
BIT 4 TRACK 0 Active high status of the TRK0 disk interface input. BIT 5 STEP Active high status of the latched STEP disk interface output pin. This bit is latched with the STEP output going active, and is cleared with a read from the DIR register, or with a hardware or software reset. BIT 6 DMA REQUEST Active high status of the FDC's DRQ output pin. BIT 7 INTERRUPT PENDING Active high bit indicating the state of the Floppy Disk Interrupt output.
SMSC DS - FDC37N958FR
Page 25
Rev. 09/01/99
STATUS REGISTER B (SRB) Floppy Disk Controller Base Address + 0x01 (READ ONLY) This register is read-only and monitors the state of several disk interface pins in PS/2 and Model 30 modes. The SRB can be accessed at any time when in PS/2 mode. In the PC/AT mode the data bus pins D0 - D7 are held in a high impedance state for a read of SRB. SRB - PS/2 Mode 7 1 RESET COND. 1 6 1 1 5 4 3 2 DRIVE WDATA RDATA WGATE SEL0 TOGGLE TOGGLE 0 0 0 0 1 MOT EN1 0 0 MOT EN0 0
BIT 0 MOTOR ENABLE 0 Active high status of the MTR0 disk interface output pin. This bit is low after a hardware reset and unaffected by a software reset. BIT 1 MOTOR ENABLE 1 Active high status of the MTR1 disk interface output pin. This bit is low after a hardware reset and unaffected by a software reset. BIT 2 WRITE GATE Active high status of the WGATE disk interface output. BIT 3 READ DATA TOGGLE Every inactive edge of the RDATA input causes this bit to change state.
BIT 4 WRITE DATA TOGGLE Every inactive edge of the WDATA output causes this bit to change state. BIT 5 DRIVE SELECT 0 Reflects the status of the Drive Select 0 bit of the DOR (address 3F2 bit 0). This bit is cleared after a hardware reset and it is unaffected by a software reset. BIT 6 RESERVED Always read as a logic "1". BIT 7 RESERVED Always read as a logic "1".
SMSC DS - FDC37N958FR
Page 26
Rev. 09/01/99
SRB - PS/2 Model 30 Mode 7 nDRV2 RESET COND. N/A 6 nDS1 1 5 nDS0 1 4 WDATA F/F 0 3 RDATA F/F 0 2 WGATE F/F 0 1 nDS3 1 0 nDS2 1
BIT 0 nDRIVE SELECT 2 Active low status of the DS2 disk interface output. BIT 1 nDRIVE SELECT 3 Active low status of the DS3 disk interface output. BIT 2 WRITE GATE Active high status of the latched WGATE output signal. This bit is latched by the active going edge of WGATE and is cleared by the read of the DIR register. BIT 3 READ DATA Active high status of the latched RDATA input signal. This bit is latched by the inactive going
edge of RDATA and is cleared by the read of the DIR register. BIT 4 WRITE DATA Active high status of the latched WDATA output signal. This bit is latched by the inactive going edge of WDATA and is cleared by the read of the DIR register. This bit is not gated with WGATE. BIT 5 nDRIVE SELECT 0 Active low status of the DS0 disk interface output. BIT 6 nDRIVE SELECT 1 Active low status of the DS1 disk interface output. BIT 7 nDRV2 Active low status of the DRV2 disk interface input.
SMSC DS - FDC37N958FR
Page 27
Rev. 09/01/99
DIGITAL OUTPUT REGISTER (DOR) FDC I/O Base Address + 0x02 (READ/WRITE) The DOR controls the drive select and motor enables of the disk interface outputs. It also 7 MOT EN3 0 6 MOT EN2 0 5 MOT EN1 0 4 MOT EN0 0
contains the enable for the DMA logic and a software reset bit. The contents of the DOR are unaffected by a software reset. The DOR can be written to at any time.
RESET COND.
3 2 DMAEN nRESE T 0 0
1 0 DRIVE DRIVE SEL1 SEL0 0 0
BIT 0 and 1 DRIVE SELECT These two bits are binary encoded for the two drive selects output pins nDS0 and nDS1, thereby allowing only one drive to be selected at one time. BIT 2 nRESET A logic "0" written to this bit resets the FDC. This reset will remain active until a logic "1" is written to this bit. This software reset does not affect the DSR and CCR registers, nor does it affect the other bits of the DOR register. The minimum reset duration required is 100ns, therefore toggling this bit by consecutive writes to this register is a valid method of issuing a software reset. BIT 3 DMAEN PC/AT and Model 30 Mode: Writing this bit to logic "1" will enable the FDC's nDACK and TC inputs and enable the FDC's DRQ and Interrupt outputs. This bit being a logic "0" will disable the FDC's nDACK and TC inputs, and hold the FDC's DRQ and Interrupt outputs in a high impedance state. This bit is a logic "0" after a reset.
PS/2 Mode: In this mode the TC and the FDC's DRQ, nDACK, and Interrupt pins are always enabled. During a reset, the DRQ, nDACK, TC, and Interrupt pins will remain enabled, but this bit will be cleared to a logic "0". BIT 4 MOTOR ENABLE 0 This bit controls the nMTR0 disk interface output. A logic "1" in this bit will cause the output pin to assert. BIT 5 MOTOR ENABLE 1 This bit controls the nMTR1 disk interface output. A logic "1" in this bit will cause the output pin to assert. BIT 6 MOTOR ENABLE 2 This bit controls the nMTR2 disk interface output. A logic "1" in this bit will cause the output pin to assert. BIT 7 MOTOR ENABLE 3 This bit controls the nMTR3 disk interface output. A logic "1" in this bit will cause the output pin to assert.
SMSC DS - FDC37N958FR
Page 28
Rev. 09/01/99
Table 8 - Drive Activation Values DRIVE DOR VALUE 0 1CH 1 2DH Table 9 - Internal 2 Drive Decode - Normal DRIVE SELECT OUTPUTS DIGITAL OUTPUT REGISTER (ACTIVE LOW) Bit 6 Bit 5 Bit 4 Bit1 Bit 0 nDS1 nDS0 X X 1 0 0 1 0 X 1 X 0 1 0 1 1 X X 1 0 1 1 X X X 1 1 1 1 0 0 0 X X 1 1
Bit 7 X X X 1 0
MOTOR ON OUTPUTS (ACTIVE LOW) nMTR1 nMTR0 nBIT 5 nBIT 4 nBIT 5 nBIT 4 nBIT 5 nBIT 4 nBIT 5 nBIT 4 nBIT 5 nBIT 4
Bit 7 X X X 1 0
Table 10 - Internal 2 Drive Decode - Drives 0 and 1 swapped DRIVE SELECT MOTOR ON OUTPUTS DIGITAL OUTPUT REGISTER OUTPUTS (ACTIVE LOW) (ACTIVE LOW) Bit 6 Bit 5 Bit 4 Bit1 Bit 0 nDS1 nDS0 nMTR1 nMTR0 X X 1 0 0 0 1 nBIT 4 nBIT 5 X 1 X 0 1 1 0 nBIT 4 nBIT 5 1 X X 1 0 1 1 nBIT 4 nBIT 5 X X X 1 1 1 1 nBIT 4 nBIT 5 0 0 0 X X 1 1 nBIT 4 nBIT 5
SMSC DS - FDC37N958FR
Page 29
Rev. 09/01/99
TAPE DRIVE REGISTER (TDR) FDC I/O Base Address + 0x03 (READ/WRITE)
the device. The TDR is unaffected by a software reset. Normal Floppy Mode
This register is included for 82077 software compatability. The robust digital data separator used in the FDC does not require its characteristics modified for tape support. The contents of this register are not used internal to DB7 Tri-state DB6 Tri-state DB5 Tri-state
Normal mode. The TDR Register contains only bits 0 and 1. When this register is read, bits 2 - 7 are a high impedance.
REG 3F3
DB4 Tri-state
DB3 Tri-state
DB2 Tri-state
DB1 DB0 tape sel 1 tape sel 0
Table 11 - Tape Select Bits TAPE SEL1 0 0 1 1 Enhanced Floppy Mode 2 (OS2) The TDR Register for Enhanced Floppy Mode 2 operation. DB7 Media ID1 DB6 Media ID0 DB5 DB4 Drive Type ID DB3 DB2 Floppy Boot Drive DB1 tape sel1 DB0 tape sel0 TAPE SEL2 0 1 0 1 DRIVE SELECTED None 1 2 3
REG 3F3
For this mode, MID[1:0] pins are gated into bits 6 and 7 of the TDR register. These two bits are not affected by a hard or soft reset.
BIT 7 MEDIA ID 1 (READ ONLY) (Pin 20) (See Table 12 - Media ID1) BIT 6 MEDIA ID 0 (READ ONLY) (Pin 19) (See Table 13)
SMSC DS - FDC37N958FR
Page 30
Rev. 09/01/99
BITS 5 and 4 Drive Type ID These bits reflect two of the bits of L0-CRF1 (Logical Device 0 - Configuration Register 0xF1).
Which two bits these are depends on the last drive selected in the Digital Output Register. (See Table 14)
Note:
Table 12 - Media ID 1 MEDIA ID1 BIT 7 Pin 19 L0-CRF1-B5 L0-CRF1-B5 =0 =1 0 0 1 1 1 0 L0-CRF1-B5 = Logical Device 0, Configuration Register F1, Bit 5 Input BIT 1 and 0 - Tape Drive Select (READ/WRITE) Same as in Normal and Enhanced Floppy Mode 2.
BITS 3 and 2 Floppy Boot Drive These bits reflect two of the bits of L0-CRF1. Bit 3 = L0-CRF1-B7. Bit 2 = L0-CRF1-B6.
Table 13 - Media ID 0 MEDIA ID0 BIT 6 Pin 20 CRF1-B4 CRF1-B4 =0 =1 0 0 1 1 1 0 Input
Table 14 - Drive Type ID DIGITAL OUTPUT REGISTER TDR REGISTER - DRIVE TYPE ID Bit 1 Bit 0 Bit 5 Bit 4 0 0 L0-CRF2 - B1 L0-CRF2 - B0 0 1 L0-CRF2 - B3 L0-CRF2 - B2 1 0 L0-CRF2 - B5 L0-CRF2 - B4 1 1 L0-CRF2 - B7 L0-CRF2 - B6 Note: L0-CRF2-Bx = Logical Device 0, Configuration Register F2, Bit x.
SMSC DS - FDC37N958FR
Page 31
Rev. 09/01/99
DATA RATE SELECT REGISTER (DSR) FDC I/O Base Address + 0x04 (WRITE ONLY) This register is write only. It is used to program the data rate, amount of write precompensation, power down status, and software reset. The data rate is programmed using the Configuration Control Register (CCR) not the DSR, for PC/AT 7 6 S/W POWER RESET DOWN 0 0 5 0 0
and PS/2 Model 30 and Microchannel applications. Other applications can set the data rate in the DSR. The data rate of the floppy controller is the most recent write of either the DSR or CCR. The DSR is unaffected by a software reset. A hardware reset will set the DSR to 02H, which corresponds to the default precompensation setting and 250 Kbps. 3 PRECOMP1 0 2 PRECOMP0 0 1 0 DRATE DRATE SEL1 SEL0 1 0
RESET COND.
4 PRECOMP2 0
BITS 0 - 1 DATA RATE SELECT These bits control the data rate of the floppy controller. See Table 16 for the settings corresponding to the individual data rates. The data rate select bits are unaffected by a software reset and are set to 250 Kbps after a hardware reset. BITS 2 - 4 PRECOMPENSATION SELECT These three bits select the value of write precompensation that will be applied to the WDATA output signal. Table 15 shows the precompensation values for the combination of these bits settings. Track 0 is the default starting track number to start precompensation. This starting track number can be changed by the configure command.
BIT 5 UNDEFINED Should be written as a logic "0". BIT 6 LOW POWER A logic "1" written to this bit will put the floppy controller into manual low power mode. The floppy controller clock and data separator circuits will be turned off. The controller will come out of manual low power mode after a software reset or access to the Data Register or Main Status Register. BIT 7 SOFTWARE RESET This active high bit has the same function as the DOR RESET (DOR bit 2) except that this bit is self clearing.
SMSC DS - FDC37N958FR
Page 32
Rev. 09/01/99
Table 15 - Precompensation Delays PRECOMPENSATION PRECOMP 432 DELAY (nsec) <2Mbps 2Mbps 0 0.00 111 20.8 41.67 001 41.7 83.34 010 62.5 125.00 011 83.3 166.67 100 104.2 208.33 101 125 250.00 110 Default Default 000 Default: See Table 17 Table 16 - Data Rates DATA RATE DATA RATE SEL1 SEL0 MFM FM 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1Meg 500 300 250 1Meg 500 500 250 1Meg 500 2Meg 250 --250 150 125 --250 250 125 --250 --125
DRIVE RATE DRT1 DRT0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
DENSEL 1 1 0 0 1 1 0 0 1 1 0 0
DRATE(1) 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0
Drive Rate Table (Recommended)
00 = 360K, 1.2M, 720K, 1.44M and 2.88M Vertical Format 01 = 3-Mode Drive 10 = 2 Meg Tape
Note 1: The DRATE and DENSEL values are mapped onto the DRIVEDEN pins.
SMSC DS - FDC37N958FR
Page 33
Rev. 09/01/99
DT1 0
DT0 0
1 0 1
0 1 1
Table 17 - DRVDEN Mapping DRVDEN1 (1) DRVDEN0 (1) DRIVE TYPE DRATE0 DENSEL 4/2/1 MB 3.5" 2/1 MB 5.25" FDDS 2/1.6/1 MB 3.5" (3-MODE) DRATE0 DRATE1 DRATE0 nDENSEL PS/2 DRATE1 DRATE0
Table 18 - Default Precompensation Delays PRECOMPENSATION DATA RATE DELAYS 20.8 ns 2 Mbps 41.67 ns 1 Mbps 125 ns 500 Kbps 125 ns 300 Kbps 125 ns 250 Kbps The 2 Mbps data rate is only available if Vcc = 5V.
SMSC DS - FDC37N958FR
Page 34
Rev. 09/01/99
MAIN STATUS REGISTER FDC I/O Base Address + 0x04 (READ ONLY) The Main Status Register is a read-only register and indicates the status of the disk controller. The Main Status Register can be read at any time. 7 RQM 6 DIO 5 NON DMA 4 CMD BUSY
The MSR indicates when the disk controller is ready to receive data via the Data Register. It should be read before each byte transferring to or from the data register except in DMA mode. No delay is required when reading the MSR after a data transfer. 3 DRV3 BUSY 2 DRV2 BUSY 1 DRV1 BUSY 0 DRV0 BUSY
BIT 0 - 3 DRVx BUSY These bits are set to 1s when a drive is in the seek portion of a command, including implied and overlapped seeks and recalibrates. BIT 4 COMMAND BUSY This bit is set to a "1" when a command is in progress. This bit will go active after the command byte has been accepted and goes inactive at the end of the results phase. If there is no result phase (Seek, Recalibrate commands), this bit is returned to a "0" after the last command byte. BIT 5 NON-DMA This mode is selected in the SPECIFY command and will be set to a "1" during the execution phase of a command. This is for polled data transfers and helps differentiate between the data transfer phase and the reading of result bytes. BIT 6 DIO Indicates the direction of a data transfer once a RQM is set. A "1" indicates a read and a "0" indicates a write is required. BIT 7 RQM Indicates that the host can transfer data if set to a "1". No access is permitted if set to a "0".
DATA REGISTER (FIFO) FDC I/O Base Address + 0x05 (READ/WRITE) All command parameter information, disk data and result status are transferred between the host processor and the FDC through the Data Register. Data transfers are governed by the RQM and DIO bits in the Main Status Register. The Data Register defaults to FIFO disabled mode after any form of reset. This maintains PC/AT hardware compatibility. The default values can be changed through the Configure command (enable full FIFO operation with threshold control). The advantage of the FIFO is that it allows the system a larger DMA latency without causing a disk error. Table 19 gives several examples of the delays with a FIFO. The data is based upon the following formula: Threshold # x [8/DATA RATE] - 1.5ms = Delay At the start of a command, the FIFO action is always disabled and command parameters must be sent based upon the RQM and DIO bit settings. As the command execution phase is entered, the FIFO is cleared of any data to ensure that invalid data is not transferred. An overrun or underrun will terminate the current command and the transfer of data. Disk writes will complete the current sector by generating a 00 pattern and valid CRC. Reads require the host to remove the remaining data so that the result phase may be entered.
SMSC DS - FDC37N958FR
Page 35
Rev. 09/01/99
Table 19 Table FIFO THRESHOLD EXAMPLES 1 byte 2 bytes 8 bytes 15 bytes FIFO THRESHOLD EXAMPLES 1 byte 2 bytes 8 bytes 15 bytes
- FIFO Service Delay MAXIMUM DELAY TO SERVICING AT 2 Mbps* DATA RATE 1 x 4 ms - 1.5 ms = 2.5 ms 2 x 4 ms - 1.5 ms = 6.5 ms 8 x 4 ms - 1.5 ms = 30.5 ms 15 x 4 ms - 1.5 ms = 58.5 ms MAXIMUM DELAY TO SERVICING AT 1 Mbps DATA RATE 1 x 8 ms - 1.5 ms = 6.5 ms 2 x 8 ms - 1.5 ms = 14.5 ms 8 x 8 ms - 1.5 ms = 62.5 ms 15 x 8 ms - 1.5 ms = 118.5 ms
FIFO THRESHOLD MAXIMUM DELAY TO SERVICING AT EXAMPLES 500 Kbps DATA RATE 1 x 16 ms - 1.5 ms = 14.5 ms 1 byte 2 x 16 ms - 1.5 ms = 30.5 ms 2 bytes 8 x 16 ms - 1.5 ms = 126.5 ms 8 bytes 15 x 16 ms - 1.5 ms = 238.5 ms 15 bytes The 2 Mbps data rate is only available if VCC = 5V nominal.
SMSC DS - FDC37N958FR
Page 36
Rev. 09/01/99
DIGITAL INPUT REGISTER (DIR) FDC I/O Base Address + 0x07 (READ ONLY) This register is read-only in all modes. DIR - PC-AT Mode 7 DSK CHG N/A 6 5 4 3 2 1 0
RESET COND.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
BIT 0 - 6 UNDEFINED The data bus outputs D0 - 6 will remain in a high impedance state during a read of this register. DIR - PS/2 Mode 7 DSK CHG N/A 6 1 N/A 5 1 N/A 4 1 N/A
BIT 7 DSKCHG This bit monitors the pin of the same name and reflects the opposite value seen on the disk cable.
3 1 N/A
RESET COND.
2 1 0 DRATE DRATE nHIGH SEL1 SEL0 DENS N/A N/A 1
BIT 0 nHIGH DENS This bit is low whenever the 500 Kbps or 1 Mbps data rates are selected, and high when 250 Kbps and 300 Kbps are selected. BITS 1 - 2 DATA RATE SELECT These bits control the data rate of the floppy controller. See Table 16 for the settings corresponding to the individual data rates. The data rate select bits are unaffected by a
software reset, and are set to 250 Kbps after a hardware reset. BITS 3 - 6 UNDEFINED Always read as a logic "1" BIT 7 DSKCHG This bit monitors the pin of the same name and reflects the opposite value seen on the disk cable.
SMSC DS - FDC37N958FR
Page 37
Rev. 09/01/99
DIR - Model 30 Mode 7 DSK CHG N/A 6 0 0 5 0 0 4 0 0 3 2 1 0 DMAEN NOPREC DRATE DRATE SEL1 SEL0 0 0 1 0
RESET COND.
BITS 0 and 1 DATA RATE SELECT These bits control the data rate of the floppy controller. See Table 16 for the settings corresponding to the individual data rates. The data rate select bits are unaffected by a software reset and are set to 250 Kbps after a hardware reset. BIT 2 NOPREC This bit reflects the value of NOPREC bit set in the CCR register.
BIT 3 DMAEN This bit reflects the value of DMAEN bit set in the DOR register bit 3. BITS 4 - 6 UNDEFINED Always read as a logic "0" BIT 7 DSKCHG This bit monitors the pin of the same name and reflects the opposite value seen on the pin.
SMSC DS - FDC37N958FR
Page 38
Rev. 09/01/99
CONFIGURATION CONTROL REGISTER (CCR) FDC I/O Base Address + 0x07 (WRITE ONLY) PC/AT and PS/2 Mode 7 6 5 4 3 2 1 0 DRATE DRATE SEL1 SEL0 1 0
RESET COND.
N/A
N/A
N/A
N/A
N/A
N/A
BIT 0 and 1 DATA RATE SELECT 0 and 1 BIT 2 - 7 RESERVED Should be set to a logical "0" CCR - PS/2 Model 30 Mode 7 6 5 4
These bits determine the data rate of the floppy controller. See Table 16 for the appropriate values.
3
RESET COND.
N/A
N/A
N/A
N/A
N/A
2 1 0 NOPREC DRATE DRATE SEL1 SEL0 N/A 1 0
BIT 0 and 1 DATA RATE SELECT 0 and 1 These bits determine the data rate of the floppy controller. See Table 16 for the appropriate values. BIT 2 NO PRECOMPENSATION This bit can be set by software, but it has no functionality. It can be read by bit 2 of the DSR when in Model 30 register mode. Unaffected by software reset.
BIT 3 - 7 RESERVED Should be set to a logical "0" Table 16 shows the state of the DENSEL pin. The DENSEL pin is set high after a hardware reset and is unaffected by the DOR and the DSR resets.
SMSC DS - FDC37N958FR
Page 39
Rev. 09/01/99
STATUS REGISTER ENCODING
During the Result Phase of certain commands, the Data Register contains data bytes that give the status of the command just executed.
BIT NO. 7,6
SYMBOL IC
5
SE
4
EC
3 2 1,0
H DS1,0
Table 20 - Status Register 0 NAME DESCRIPTION Interrupt Code 00 - Normal termination of command. The specified command was properly executed and completed without error. 01 - Abnormal termination of command. Command execution was started, but was not successfully completed. 10 - Invalid command. The requested command could not be executed. 11 - Abnormal termination caused by Polling. Seek End The FDC completed a Seek, Relative Seek or Recalibrate command (used during a Sense Interrupt Command). Equipment The TRK0 pin failed to become a "1" after: Check 1. Step pulses in the Recalibrate command. 2. The Relative Seek command caused the FDC to step outward beyond Track 0. Unused. This bit is always "0". Head Address The current head address. Drive Select The current selected drive.
SMSC DS - FDC37N958FR
Page 40
Rev. 09/01/99
BIT NO. 7
6 5 4
3 2
1 0
Table 21 - Status Register 1 SYMBOL NAME DESCRIPTION EN End of Cylinder The FDC tried to access a sector beyond the final sector of the track (255D). Will be set if TC is not issued after Read or Write Data command. Unused. This bit is always "0". DE Data Error The FDC detected a CRC error in either the ID field or the data field of a sector. OR Overrun/ Becomes set if the FDC does not receive CPU or DMA Underrun service within the required time interval, resulting in data overrun or underrun. Unused. This bit is always "0". ND No Data Any one of the following: 1. Read Data, Read Deleted Data command - the FDC did not find the specified sector. 2. Read ID command - the FDC cannot read the ID field without an error. 3. Read A Track command - the FDC cannot find the proper sector sequence. NW Not Writable WP pin became a "1" while the FDC is executing a Write Data, Write Deleted Data, or Format A Track command. MA Missing Address Any one of the following: Mark 1. The FDC did not detect an ID address mark at the specified track after encountering the index pulse from the IDX pin twice. 2. The FDC cannot detect a data address mark or a deleted data address mark on the specified track.
SMSC DS - FDC37N958FR
Page 41
Rev. 09/01/99
BIT NO. 7 6
SYMBOL CM
5 4 3 2 1
DD WC
BC
0
MD
Table 22 - Status Register 2 DESCRIPTION Unused. This bit is always "0". Control Mark Any one of the following: 1. Read Data command - the FDC encountered a deleted data address mark. 2. Read Deleted Data command - the FDC encountered a data address mark. Data Error in The FDC detected a CRC error in the data field. Data Field Wrong Cylinder The track address from the sector ID field is different from the track address maintained inside the FDC. Unused. This bit is always "0". Unused. This bit is always "0". Bad Cylinder The track address from the sector ID field is different from the track address maintained inside the FDC and is equal to FF hex, which indicates a bad track with a hard error according to the IBM soft-sectored format. Missing Data The FDC cannot detect a data address mark or a deleted Address Mark data address mark. NAME
BIT NO. 7 6 5 4 3 2 1,0 FDC RESET
SYMBOL WP T0 HD DS1,0
Table 23 - Status Register 3 DESCRIPTION Unused. This bit is always "0". Write Protected Indicates the status of the WP pin. Unused. This bit is always "1". Track 0 Indicates the status of the TRK0 pin. Unused. This bit is always "1". Head Address Indicates the status of the HDSEL pin. Drive Select Indicates the status of the nDS1, nDS0 pins. NAME command information, and the Floppy Disk Controller waits for a new command. Drive polling will start unless disabled by a new Configure command.
There are three sources of system reset on the FDC: the nRESET_OUT bit of the 8051's Output enable Register (which controls the RESET_OUT/nRESET_OUT pins of the FDC37N958FR); a reset generated via a bit in the DOR; and a reset generated via a bit in the DSR. At VCC2 power on, a VCC2 Power On Reset initializes the FDC. All resets take the FDC out of the power down state. All operations are terminated upon a RESET, and the Floppy Disk Controller enters an idle state. A reset while a disk write is in progress will corrupt the data and CRC. On exiting the reset state, various internal registers are cleared, including the Configure
SMSC DS - FDC37N958FR
Page 42
Rev. 09/01/99
RESET_OUT Pin (Hardware Reset) The RESET_OUT pin is a global reset and clears all registers except those programmed by the Specify command. The DOR reset bit is enabled and must be cleared by the host to exit the reset state. DOR Reset vs. DSR Reset (Software Reset) These two resets are functionally the same. Both will reset the FDC core, which affects drive status information and the FIFO circuits. The DSR reset clears itself automatically while the DOR reset requires the host to manually clear it. DOR reset has precedence over the DSR reset. The DOR reset is set automatically upon a RESET_OUT pin reset. The user must manually clear this reset bit in the DOR to exit the reset state. FDC MODES OF OPERATION
command. The FIFO is enabled directly by asserting nDACK and addresses need not be valid. Note that if the DMA controller (i.e. 8237A) is programmed to function in verify mode, a pseudo read is performed by the FDC based only on nDACK. This mode is only available when the FDC has been configured into byte mode (FIFO disabled) and is programmed to do a read. With the FIFO enabled, the FDC can perform the above operation by using the new Verify command; no DMA operation is needed. CONTROLLER PHASES For simplicity, command handling in the FDC can be divided into three phases: Command, Execution, and Result. Each phase is described in the following sections. Command Phase
The FDC has three modes of operation, PC/AT mode, PS/2 mode and Model 30 mode. These are determined by the state of IDENT and MFM, bits[3] and [2] respectively of L0-CRF0. PC/AT mode - (IDENT high, MFM a "don't care") The PC/AT register set is enabled, the DMA enable bit of the DOR becomes valid (The FDC's IRQ and DRQ can be hi-Z), and TC and DENSEL become active high signals. PS/2 mode - (IDENT low, MFM high) This mode supports the PS/2 models 50/60/80 configuration and register set. The DMA bit of the DOR becomes a "don't care", (the FDC's IRQ and DRQ are always valid), TC and DENSEL become active low. Model 30 mode - (IDENT low, MFM low) This mode supports PS/2 Model 30 configuration and register set. The DMA enable bit of the DOR becomes valid (The FDC's IRQ and DRQ can be hi-Z), TC is active high and DENSEL is active low. DMA TRANSFERS DMA transfers are enabled with the Specify command and are initiated by the FDC by activating its DRQ pin during a data transfer
After a reset, the FDC enters the command phase and is ready to accept a command from the host. For each of the commands, a defined set of command code bytes and parameter bytes has to be written to the FDC before the command phase is complete. (Please refer to Table 24 for the command set descriptions). These bytes of data must be transferred in the order prescribed. Before writing to the FDC, the host must examine the RQM and DIO bits of the Main Status Register. RQM and DIO must be equal to "1" and "0" respectively before command bytes may be written. RQM is set false by the FDC after each write cycle until the received byte is processed. The FDC asserts RQM again to request each parameter byte of the command unless an illegal command condition is detected. After the last parameter byte is received, RQM remains "0" and the FDC automatically enters the next phase as defined by the command definition. The FIFO is disabled during the command phase to provide for the proper handling of the "Invalid Command" condition.
SMSC DS - FDC37N958FR
Page 43
Rev. 09/01/99
Execution Phase All data transfers to or from the FDC occur during the execution phase, which can proceed in DMA or non-DMA mode as indicated in the Specify command. After a reset, the FIFO is disabled. Each data byte is transferred by an FDC IRQ or DRQ depending on the DMA mode. The Configure command can enable the FIFO and set the FIFO threshold value. The following paragraphs detail the operation of the FIFO flow control. In these descriptions, is defined as the number of bytes available to the FDC when service is requested from the host and ranges from 1 to 16. The parameter FIFOTHR, which the user programs, is one less and ranges from 0 to 15. A low threshold value (i.e. 2) results in longer periods of time between service requests, but requires faster servicing of the request for both read and write cases. The host reads (writes) from (to) the FIFO until empty (full), then the transfer request goes inactive. The host must be very responsive to the service request. This is the desired case for use with a "fast" system. A high value of threshold (i.e. 12) is used with a "sluggish" system by affording a long latency period after a service request, but results in more frequent service requests. Non-DMA Mode - Transfers from the FIFO to the Host The FDC's IRQ pin and RQM bits in the Main Status Register are activated when the FIFO contains (16-) bytes or the last bytes of a full sector have been placed in the FIFO. The FDC's IRQ pin can be used for interrupt-driven systems, and RQM can be used for polled systems. The host must respond to the request by reading data from the FIFO. This process is repeated until the last byte is transferred out of the FIFO. The FDC will deactivate the FDC's IRQ pin and RQM bit when the FIFO becomes empty.
Non-DMA Mode - Transfers from the Host to the FIFO The FDC's IRQ pin and RQM bit in the Main Status Register are activated upon entering the execution phase of data transfer commands. The host must respond to the request by writing data into the FIFO. The FDC's IRQ pin and RQM bit remain true until the FIFO becomes full. They are set true again when the FIFO has bytes remaining in the FIFO. The FDC's IRQ pin will also be deactivated if TC and nDACK both go inactive. The FDC enters the result phase after the last byte is taken by the FDC from the FIFO (i.e. FIFO empty condition). DMA Mode - Transfers from the FIFO to the Host The FDC activates the FDC's DRQ pin when the FIFO contains (16 - ) bytes, or the last byte of a full sector transfer has been placed in the FIFO. The DMA controller must respond to the request by reading data from the FIFO. The FDC will deactivate the FDC's DRQ pin when the FIFO becomes empty. FDC's DRQ goes inactive after nDACK goes active for the last byte of a data transfer (or on the active edge of nIOR, on the last byte, if no edge is present on nDACK). A data underrun may occur if the FDC's DRQ is not removed in time to prevent an unwanted cycle. DMA Mode - Transfers from the Host to the FIFO The FDC activates the FDC's DRQ pin when entering the execution phase of the data transfer commands. The DMA controller must respond by activating the nDACK and nIOW pins placing data in the FIFO. The FDC's DRQ remains active until the FIFO becomes full. The FDC's DRQ is again set true when the FIFO has bytes remaining in the FIFO. The FDC will also deactivate the FDC's DRQ pin when TC becomes true (qualified by nDACK), indicating that no more data is required. The FDC's DRQ goes inactive after nDACK goes active for the last byte of a data transfer (or on the active edge of nIOW of the last byte, if no edge is present on nDACK). A data overrun may occur if the FDC's DRQ is not removed in time to prevent an unwanted cycle.
SMSC DS - FDC37N958FR
Page 44
Rev. 09/01/99
Data Transfer Termination The FDC supports terminal count explicitly through the TC pin and implicitly through the underrun/overrun and end-of-track (EOT) functions. For full sector transfers, the EOT parameter can define the last sector to be transferred in a single or multi-sector transfer. If the last sector to be transferred is a partial sector, the host can stop transferring the data in mid-sector, and the FDC will continue to complete the sector as if a hardware TC was received. The only difference between these implicit functions and TC is that they return "abnormal termination" result status. Such status indications can be ignored if they were expected. Note that when the host is sending data to the FIFO of the FDC, the internal sector count will be complete when the FDC reads the last byte from its side of the FIFO. There may be a delay in the removal of the transfer request signal of up to the time taken for the FDC to read the last 16 bytes from the FIFO. The host must tolerate this delay.
Result Phase The generation of the FDC's IRQ determines the beginning of the result phase. For each of the commands, a defined set of result bytes has to be read from the FDC before the result phase is complete. These bytes of data must be read out for another command to start. RQM and DIO must both equal "1" before the result bytes may be read. After all the result bytes have been read, the RQM and DIO bits switch to "1" and "0" respectively, and the CB bit is cleared, indicating that the FDC is ready to accept the next command.
SMSC DS - FDC37N958FR
Page 45
Rev. 09/01/99
COMMAND SET/DESCRIPTIONS Commands can be written whenever the FDC is in the command phase. Each command has a unique set of needed parameters and status results. The FDC checks to see that the first byte is a valid command and, if valid, proceeds with
the command. If it is invalid, an interrupt is issued. The user sends a Sense Interrupt Status command which returns an invalid command error. Refer to Table 24 for explanations of the various symbols used. Table 25 lists the required parameters and the results associated with each command that the FDC is capable of performing.
SMSC DS - FDC37N958FR
Page 46
Rev. 09/01/99
SYMBOL C D D0, D1, D2, D3 DIR
DS0, DS1
Table 24 - Description of the FDC Command Symbols NAME DESCRIPTION Cylinder Address The currently selected address; 0 to 255. Data Pattern The pattern to be written in each sector data field during formatting. Drive Select 0-3 Designates which drives are perpendicular drives on the Perpendicular Mode Command. A "1" indicates a perpendicular drive. Direction Control If this bit is 0, then the head will step out from the spindle during a relative seek. If set to a 1, the head will step in toward the spindle. Disk Drive Select DS1 DS0 DRIVE 0 0 1 1 0 1 0 1 drive 0 drive 1 drive 2 drive 3
DTL
Special Sector Size
EC EFIFO EIS
Enable Count Enable FIFO Enable Implied Seek End of Track Gap Length Head Address Head Load Time
EOT GAP GPL H/HDS HLT
HUT
Head Unload Time
LOCK
By setting N to zero (00), DTL may be used to control the number of bytes transferred in disk read/write commands. The sector size (N = 0) is set to 128. If the actual sector (on the diskette) is larger than DTL, the remainder of the actual sector is read but is not passed to the host during read commands; during write commands, the remainder of the actual sector is written with all zero bytes. The CRC check code is calculated with the actual sector. When N is not zero, DTL has no meaning and should be set to FF HEX. When this bit is "1" the "DTL" parameter of the Verify command becomes SC (number of sectors per track). This active low bit when a 0, enables the FIFO. A "1" disables the FIFO (default). When set, a seek operation will be performed before executing any read or write command that requires the C parameter in the command phase. A "0" disables the implied seek. The final sector number of the current track. Alters Gap 2 length when using Perpendicular Mode. The Gap 3 size. (Gap 3 is the space between sectors excluding the VCO synchronization field). Selected head: 0 or 1 (disk side 0 or 1) as encoded in the sector ID field. The time interval that the FDC waits after loading the head and before initializing a read or write operation. Refer to the Specify command for actual delays. The time interval from the end of the execution phase (of a read or write command) until the head is unloaded. Refer to the Specify command for actual delays. Lock defines whether EFIFO, FIFOTHR, and PRETRK parameters of the CONFIGURE COMMAND can be reset to their default values by a "software Reset". (A reset caused by
SMSC DS - FDC37N958FR
Page 47
Rev. 09/01/99
SYMBOL MFM MT
NAME MFM/FM Mode Selector Multi-Track Selector
N
Sector Size Code
NCN ND
New Cylinder Number Non-DMA Mode Flag
DESCRIPTION writing to the appropriate bits of either tha DSR or DOR) A one selects the double density (MFM) mode. A zero selects single density (FM) mode. When set, this flag selects the multi-track operating mode. In this mode, the FDC treats a complete cylinder under head 0 and 1 as a single track. The FDC operates as this expanded track started at the first sector under head 0 and ended at the last sector under head 1. With this flag set, a multitrack read or write operation will automatically continue to the first sector under head 1 when the FDC finishes operating on the last sector under head 0. This specifies the number of bytes in a sector. If this parameter is "00", then the sector size is 128 bytes. The number of bytes transferred is determined by the DTL parameter. Otherwise the sector size is (2 raised to the "N'th" power) times 128. All values up to "07" hex are allowable. "07"h would equal a sector size of 16k. It is the user's responsibility to not select combinations that are not possible with the drive. N SECTOR SIZE 00 128 bytes 01 256 bytes 02 512 bytes 03 1024 bytes ... ... 07 16 Kbytes The desired cylinder number. When set to 1, indicates that the FDC is to operate in the nonDMA mode. In this mode, the host is interrupted for each data transfer. When set to 0, the FDC operates in DMA mode, interfacing to a DMA controller by means of the DRQ and nDACK signals. The bits D0-D3 of the Perpendicular Mode Command can only be modified if OW is set to 1. OW id defined in the Lock command. The current position of the head at the completion of Sense Interrupt Status command. When set, the internal polling routine is disabled. When clear, polling is enabled. Programmable from track 00 to FFH.
OW
Overwrite
PCN POLL PRETRK
Present Cylinder Number Polling Disable Precompensation Start Track Number Sector Address
R
RCN SC
Relative Cylinder Number Number of Sectors Per Track
The sector number to be read or written. In multi-sector transfers, this parameter specifies the sector number of the first sector to be read or written. Relative cylinder offset from present cylinder as used by the Relative Seek command. The number of sectors per track to be initialized by the Format command. The number of sectors per track to be verified during
SMSC DS - FDC37N958FR
Page 48
Rev. 09/01/99
SYMBOL SK
NAME Skip Flag
SRT
Step Rate Interval
ST0 ST1 ST2 ST3 WGATE
Status 0 Status 1 Status 2 Status 3 Write Gate
DESCRIPTION a Verify command when EC is set. When set to 1, sectors containing a deleted data address mark will automatically be skipped during the execution of Read Data. If Read Deleted is executed, only sectors with a deleted address mark will be accessed. When set to "0", the sector is read or written the same as the read and write commands. The time interval between step pulses issued by the FDC. Programmable from 0.5 to 8 milliseconds in increments of 0.5 ms at the 1 Mbit data rate. Refer to the SPECIFY command for actual delays. Registers within the FDC which store status information after a command has been executed. This status information is available to the host during the result phase after command execution. Alters timing of WE to allow for pre-erase loads in perpendicular drives.
SMSC DS - FDC37N958FR
Page 49
Rev. 09/01/99
FDC INSTRUCTION SET
Table 25 - FDC Instruction Set READ DATA DATA BUS PHASE Command R/W D7 W W W W W W W W W Execution Result R R R R R R R ------- ST0 ------------- ST1 ------------- ST2 -------------- C --------------- H --------------- R --------------- N -------Sector ID information after Command execution. MT 0 D6 MFM 0 D5 SK 0 D4 0 0 D3 0 0 D2 1 D1 1 D0 0 Command Codes Sector ID information prior to Command execution. REMARKS
HDS DS1 DS0
-------- C --------------- H --------------- R --------------- N -------------- EOT ------------- GPL ------------- DTL -------
Data transfer between the FDD and system. Status information after Command execution.
SMSC DS - FDC37N958FR
Page 50
Rev. 09/01/99
READ DELETED DATA DATA BUS PHASE Command R/W W W W W W W W W W Execution Result R R R R R R R ------- ST0 ------------- ST1 ------------- ST2 -------------- C --------------- H --------------- R --------------- N -------Sector ID information after Command execution. D7 MT 0 D6 MFM 0 D5 SK 0 D4 0 0 D3 1 0 D2 1 D1 0 D0 0 REMARKS Command Codes Sector ID information prior to Command execution.
HDS DS1 DS0
-------- C --------------- H --------------- R --------------- N -------------- EOT ------------- GPL ------------- DTL -------
Data transfer between the FDD and system. Status information after Command execution.
SMSC DS - FDC37N958FR
Page 51
Rev. 09/01/99
WRITE DATA PHASE Command R/W W W W W W W W W W Execution Result R R R R R R R ------- ST0 ------------- ST1 ------------- ST2 -------------- C --------------- H --------------- R --------------- N -------Sector ID information after Command execution. D7 MT 0 D6 MFM 0 D5 0 0 DATA BUS D4 D3 0 0 0 0 D2 1 D1 0 D0 REMARKS 1 Command Codes Sector ID information prior to Command execution.
HDS DS1 DS0
-------- C --------------- H --------------- R --------------- N -------------- EOT ------------- GPL ------------- DTL -------
Data transfer between the FDD and system. Status information after Command execution.
SMSC DS - FDC37N958FR
Page 52
Rev. 09/01/99
WRITE DELETED DATA PHASE Command R/W W W W D7 MT 0 D6 MFM 0 D5 0 0 DATA BUS D4 D3 D2 0 1 0 0 0 HDS -------- C -------D1 0 DS1 D0 1 DS0 Sector ID information prior to Command execution. REMARKS Command Codes
W W W W W W Execution Result R R R R
-------- H --------------- R --------------- N -------------- EOT ------------- GPL ------------- DTL ------Data transfer between the FDD and system. ------- ST0 ------------- ST1 ------------- ST2 -------------- C -------Sector ID information after Command execution. Status information after Command execution.
R R R
-------- H --------------- R --------------- N --------
SMSC DS - FDC37N958FR
Page 53
Rev. 09/01/99
READ A TRACK PHASE Command R/W W W W D7 0 0 D6 MFM 0 D5 0 0 DATA BUS D4 D3 D2 0 0 0 0 0 HDS -------- C -------D1 1 DS1 D0 0 DS0 Sector ID information prior to Command execution. REMARKS Command Codes
W W W W W W Execution
-------- H --------------- R --------------- N -------------- EOT ------------- GPL ------------- DTL ------Data transfer between the FDD and system. FDC reads all of cylinders' contents from index hole to EOT.
Result
R R R R
------- ST0 ------------- ST1 ------------- ST2 -------------- C --------
Status information after Command execution.
Sector ID information after Command execution.
R R R
-------- H --------------- R --------------- N --------
SMSC DS - FDC37N958FR
Page 54
Rev. 09/01/99
VERIFY PHASE Command R/W W W W D7 MT EC D6 MFM 0 D5 SK 0 DATA BUS D4 D3 D2 1 0 1 0 0 HDS -------- C -------D1 1 DS1 D0 0 DS0 Sector ID information prior to Command execution. REMARKS Command Codes
W W W W W W Execution Result R R R R
-------- H --------------- R --------------- N -------------- EOT ------------- GPL ------------ DTL/SC -----No data transfer takes place. ------- ST0 ------------- ST1 ------------- ST2 -------------- C -------Sector ID information after Command execution. Status information after Command execution.
R R R
-------- H --------------- R --------------- N -------VERSION
PHASE Command Result
R/W W R
D7 0 1
D6 0 0
D5 0 0
DATA BUS D4 D3 D2 1 0 0 1 0 0
D1 0 0
D0 0 0
REMARKS Command Code Enhanced Controller
SMSC DS - FDC37N958FR
Page 55
Rev. 09/01/99
FORMAT A TRACK PHASE Command R/W W W W W W W Execution for Each Sector Repeat: W D7 0 0 D6 MFM 0 D5 0 0 DATA BUS D4 D3 D2 0 1 1 0 0 HDS -------- N --------------- SC -------------- GPL -------------- D --------------- C -------D1 0 DS1 D0 1 DS0 Bytes/Sector Sectors/Cylinder Gap 3 Filler Byte Input Sector Parameters REMARKS Command Codes
W W W
-------- H --------------- R --------------- N -------FDC formats an entire cylinder
Result
R R R R R R R
------- ST0 ------------- ST1 ------------- ST2 ------------ Undefined ----------- Undefined ----------- Undefined ----------- Undefined ------
Status information after Command execution
RECALIBRATE PHASE Command Execution R/W W W D7 0 0 D6 0 0 D5 0 0 DATA BUS D4 D3 D2 0 0 1 0 0 0 D1 1 DS1 D0 1 DS0 Head retracted to Track 0 Interrupt. REMARKS Command Codes
SMSC DS - FDC37N958FR
Page 56
Rev. 09/01/99
SENSE INTERRUPT STATUS PHASE Command Result R/W W R R D7 0 D6 0 D5 0 DATA BUS D4 D3 D2 0 1 0 D1 0 D0 0 REMARKS Command Codes Status information at the end of each seek operation.
------- ST0 ------------- PCN ------SPECIFY
PHASE Command
R/W W W W
D7 0
D6 0
D5 0
DATA BUS D4 D3 D2 0 0 0
D1 1
D0 1 ND
REMARKS Command Codes
--- SRT -------- HLT ------
--- HUT ---
SENSE DRIVE STATUS PHASE Command Result R/W W W R D7 0 0 D6 0 0 D5 0 0 DATA BUS D4 D3 D2 0 0 1 0 0 HDS ------- ST3 ------D1 0 DS1 D0 0 DS0 Status information about FDD REMARKS Command Codes
SMSC DS - FDC37N958FR
Page 57
Rev. 09/01/99
SEEK PHASE Command R/W W W W Execution D7 0 0 D6 0 0 D5 0 0 DATA BUS D4 D3 D2 0 1 1 0 0 HDS ------- NCN ------Head positioned over proper cylinder on diskette. CONFIGURE PHASE Command R/W W W W Execution W D7 0 0 0 D6 0 0 D5 0 0 DATA BUS D4 D3 1 0 0 POLL 0 D2 0 0 D1 1 0 D0 1 0 REMARKS Configure Information D1 1 DS1 D0 1 DS0 REMARKS Command Codes
EIS EFIFO
--- FIFOTHR ---
--------- PRETRK --------RELATIVE SEEK
PHASE Command
R/W W W W
D7 1 0
D6 DIR 0
D5 0 0
DATA BUS D4 D3 D2 0 1 1 0 0 HDS ------- RCN -------
D1 1 DS1
D0 1 DS0
REMARKS
SMSC DS - FDC37N958FR
Page 58
Rev. 09/01/99
DUMPREG PHASE Command R/W W D7 0 D6 0 D5 0 DATA BUS D4 D3 D2 0 1 1 D1 1 D0 0 REMARKS *Note: Registers placed in FIFO
Execution Result R R R R R R R R R R LOCK 0 0 D3 ------ PCN-Drive 0 ------------ PCN-Drive 1 ------------ PCN-Drive 2 ------------ PCN-Drive 3 ---------- SRT ---------- HLT ------------- SC/EOT ------D2 POLL D1 D0 GAP WGATE EIS EFIFO -- FIFOTHR ---- HUT --ND
-------- PRETRK --------
SMSC DS - FDC37N958FR
Page 59
Rev. 09/01/99
READ ID PHASE Command Execution R/W W W D7 0 0 D6 MFM 0 D5 0 0 DATA BUS D4 D3 D2 0 1 0 0 0 HDS D1 1 DS1 D0 0 DS0 The first correct ID information on the Cylinder is stored in Data Register R -------- ST0 -------Status information after Command execution. REMARKS Commands
Result
Disk status after the Command has completed R R R R R R -------- ST1 --------------- ST2 --------------- C --------------- H --------------- R --------------- N -------PERPENDICULAR MODE PHASE Command R/W W D7 0 OW D6 0 0 D5 0 D3 DATA BUS D4 D3 D2 1 0 0 D2 D1 D0 D1 1 GAP D0 0 WGATE REMARKS Command Codes
SMSC DS - FDC37N958FR
Page 60
Rev. 09/01/99
INVALID CODES PHASE Command R/W W D7 D6 DATA BUS D5 D4 D3 D2 D1 ----- Invalid Codes ----D0 REMARKS Invalid Command Codes (NoOp - FDC goes into Standby State) ST0 = 80H
Result
R
------- ST0 -------
LOCK PHASE Command Result R/W W R D7 LOCK 0 D6 0 0 D5 0 0 DATA BUS D4 D3 1 0 LOCK 0 D2 1 0 D1 0 0 D0 0 0 REMARKS Command Codes
SC is returned if the last command that was issued was the Format command. EOT is returned if the last command was a Read or Write. Note: These bits are used internally only. They are not reflected in the Drive Select pins. It is the user's responsibility to maintain correspondence between these bits and the Drive Select pins (DOR).
SMSC DS - FDC37N958FR
Page 61
Rev. 09/01/99
FDC DATA TRANSFER COMMANDS
All of the Read Data, Write Data and Verify type commands use the same parameter bytes and return the same results information, the only difference being the coding of bits 0-4 in the first byte. An implied seek will be executed if the feature was enabled by the Configure command. This seek is completely transparent to the user. The Drive Busy bit for the drive will go active in the Main Status Register during the seek portion of the command. If the seek portion fails, it will be reflected in the results status normally returned for a Read/Write Data command. Status Register 0 (ST0) would contain the error code and C would contain the cylinder on which the seek failed. Read Data A set of nine (9) bytes is required to place the FDC in the Read Data Mode. After the Read Data command has been issued, the FDC loads the head (if it is in the unloaded state), waits the specified head settling time (defined in the Specify command), and begins reading ID Address Marks and ID fields. When the sector address read off the diskette matches with the sector address specified in the command, the FDC reads the sector's data field and transfers the data to the FIFO. After completion of the read operation from the current sector, the sector address is incremented by one and the data from the next logical sector is read and output via the FIFO. This continuous read function is called "Multi-Sector Read Operation". Upon receipt of TC, or an implied TC (FIFO overrun/underrun), the FDC stops sending data but will continue to read data from the current sector, check the CRC bytes, and at the end of the sector, terminate the Read Data Command. N determines the number of bytes per sector (see Table 26 below). If N is set to zero, the sector size is set to 128. The DTL value determines the number of bytes to be transferred. If DTL is less than 128, the FDC transfers the specified number of bytes to the host. For reads, it continues to read the entire 128-byte sector and checks for CRC errors. For writes, it completes the 128-byte sector by filling in zeros. If N is not set to 00 Hex, DTL should be set to FF Hex and has no impact on the number of bytes transferred.
N 00 01 02 03 .. 07
Table 26 - Sector Sizes SECTOR SIZE 128 bytes 256 bytes 512 bytes 1024 bytes ... 16 Kbytes (multi-track) and N (number of bytes/sector).
The amount of data which can be handled with a single command to the FDC depends upon MT
SMSC DS - FDC37N958FR
Page 62
Rev. 09/01/99
The Multi-Track function (MT) allows the FDC to read data from both sides of the diskette. For a particular cylinder, data will be transferred starting at Sector 1, Side 0 and completing the last sector of the same track at Side 1. If the host terminates a read or write operation in the FDC, the ID information in the result phase is dependent upon the state of the MT bit and EOT byte. At the completion of the Read Data command, the head is not unloaded until after the Head Unload Time Interval (specified in the Specify command) has elapsed. If the host issues another command before the head unloads, then the head settling time may be saved between subsequent reads.
If the FDC detects a pulse on the nINDEX pin twice without finding the specified sector (meaning that the diskette's index hole passes through index detect logic in the drive twice), the FDC sets the IC code in Status Register 0 to "01" indicating abnormal termination, sets the ND bit in Status Register 1 to "1" indicating a sector not found, and terminates the Read Data Command. After reading the ID and Data Fields in each sector, the FDC checks the CRC bytes. If a CRC error occurs in the ID or data field, the FDC sets the IC code in Status Register 0 to "01" indicating abnormal termination, sets the DE bit flag in Status Register 1 to "1", sets the DD bit in Status Register 2 to "1" if CRC is incorrect in the ID field, and terminates the Read Data Command. Table 28 describes the effect of the SK bit on the Read Data command execution and results. Except where noted in Table 28, the C or R value of the sector address is automatically incremented (see Table 30).
MT 0 1 0 1 0 1
N 1 1 2 2 3 3
Table 27 - Effects of MT and N Bits MAXIMUM TRANSFER FINAL SECTOR READ CAPACITY FROM DISK 26 at side 0 or 1 256 x 26 = 6,656 26 at side 1 256 x 52 = 13,312 15 at side 0 or 1 512 x 15 = 7,680 15 at side 1 512 x 30 = 15,360 8 at side 0 or 1 1024 x 8 = 8,192 16 at side 1 1024 x 16 = 16,384
SMSC DS - FDC37N958FR
Page 63
Rev. 09/01/99
SK BIT VALUE
Table 28 - Skip Bit vs Read Data Command DATA ADDRESS MARK TYPE RESULTS ENCOUNTERED SECTOR CM BIT OF DESCRIPTION OF READ? ST2 SET? RESULTS Normal Data Deleted Data Yes Yes No Yes Normal termination Address not incremented. Next sector not searched for Normal termination Normal termination. Sector not read ("skipped")
0 0
1 1
Normal Data Deleted Data
Yes No
No Yes
Read Deleted Data This command is the same as the Read Data command, only it operates on sectors that contain a Deleted Data Address Mark at the beginning of a Data Field. Table 29 describes the effect of the
SK bit on the Read Deleted Data command execution and results. Except where noted in Table 29, the C or R value of the sector address is automatically incremented (see Table 30).
SMSC DS - FDC37N958FR
Page 64
Rev. 09/01/99
SK BIT VALUE
Table 29 - Skip Bit vs. Read Deleted Data Command DATA ADDRESS MARK TYPE RESULTS ENCOUNTERED SECTOR CM BIT OF DESCRIPTION OF READ? ST2 SET? RESULTS Normal Data Yes Yes Address not incremented. Next sector not searched for Normal termination Normal termination. Sector not read ("skipped") Normal termination
0
0 1
Deleted Data Normal Data
Yes No
No Yes
1 Read A Track
Deleted Data
Yes
No
This command is similar to the Read Data command except that the entire data field is read continuously from each of the sectors of a track. Immediately after encountering a pulse on the nINDEX pin, the FDC starts to read all data fields on the track as continuous blocks of data without regard to logical sector numbers. If the FDC finds an error in the ID or DATA CRC check bytes, it continues to read data from the track and sets the appropriate error bits at the end of the command. The FDC compares the ID information read from each sector with the specified value in the command and sets the ND flag of Status
Register 1 to a "1" if there is no comparison. Multi-track or skip operations are not allowed with this command. The MT and SK bits (bits D7 and D5 of the first command byte respectively) should always be set to "0". This command terminates when the EOT specified number of sectors has not been read. If the FDC does not find an ID Address Mark on the diskette after the second occurrence of a pulse on the IDX pin, then it sets the IC code in Status Register 0 to "01" (abnormal termination), sets the MA bit in Status Register 1 to "1", and terminates the command.
SMSC DS - FDC37N958FR
Page 65
Rev. 09/01/99
MT
HEAD
Table 30 - Result Phase Table FINAL SECTOR TRANSFERRED TO ID INFORMATION AT RESULT PHASE HOST C H R N Less than EOT NC NC R+1 NC
0 0 Equal to EOT Less than EOT 1 Equal to EOT Less than EOT 0 1 Equal to EOT Less than EOT 1 Equal to EOT C+1 LSB 01 NC NC NC LSB NC 01 R+1 NC NC C+1 NC NC NC 01 R+1 NC NC C+1 NC NC NC 01 R+1 NC NC
NC: No Change, the same value as the one at the beginning of command execution. LSB: Least Significant Bit, the LSB of H is complemented. Write Data After the Write Data command has been issued, the FDC loads the head (if it is in the unloaded state), waits the specified head load time if unloaded (defined in the Specify command), and begins reading ID fields. When the sector address read from the diskette matches the sector address specified in the command, the FDC reads the data from the host via the FIFO and writes it to the sector's data field. After writing data into the current sector, the FDC computes the CRC value and writes it into the CRC field at the end of the sector transfer. The Sector Number stored in "R" is incremented by one, and the FDC continues writing to the next data field. The FDC continues this "Multi-Sector Write Operation". Upon receipt of a terminal count signal or if a FIFO over/under run occurs while a data field is being written, then the remainder of the data field is filled with zeros. The FDC reads the ID field of each sector and checks the CRC bytes. If it detects a CRC error in one of the ID fields, it sets the IC code in Status Register 0 to "01" (abnormal termination), sets the DE bit of Status Register 1 to "1", and terminates the Write Data command.
SMSC DS - FDC37N958FR
Page 66
Rev. 09/01/99
The Write Data command operates in much the same manner as the Read Data command. The following items are the same. Please refer to the Read Data Command for details: ! ! ! ! ! ! Transfer Capacity EN (End of Cylinder) bit ND (No Data) bit Head Load, Unload Time Interval ID information when the host terminates the command Definition of DTL when N = 0 and when N does not = 0
a Read Data command except that no data is transferred to the host. Data is read from the disk and CRC is computed and checked against the previously-stored value. Because data is not transferred to the host, TC (pin 94) cannot be used to terminate this command. By setting the EC bit to "1", an implicit TC will be issued to the FDC. This implicit TC will occur when the SC value has decremented to 0 (an SC value of 0 will verify 256 sectors). This command can also be terminated by setting the EC bit to "0" and the EOT value equal to the final sector to be checked. If EC is set to "0", DTL/SC should be programmed to 0FFH. Refer to Table 30 and Table 31 for information concerning the values of MT and EC versus SC and EOT value. Definitions: # Sectors Per Side = Number of formatted sectors per each side of the disk. # Sectors Remaining = Number of formatted sectors left which can be read, including side 1 of the disk if MT is set to "1".
Write Deleted Data This command is almost the same as the Write Data command except that a Deleted Data Address Mark is written at the beginning of the Data Field instead of the normal Data Address Mark. This command is typically used to mark a bad sector containing an error on the floppy disk. Verify The Verify command is used to verify the data stored on a disk. This command acts exactly like
SMSC DS - FDC37N958FR
Page 67
Rev. 09/01/99
MT 0 0 0 0 1 1 1 1
EC 0 0 1 1 0 0 1 1
Table 31 - Verify Command Result Phase Table SC/EOT VALUE TERMINATION RESULT SC = DTL EOT & # Sectors Per Side SC = DTL EOT > # Sectors Per Side SC & # Sectors Remaining AND EOT & # Sectors Per Side SC > # Sectors Remaining OR EOT > # Sectors Per Side SC = DTL EOT & # Sectors Per Side SC = DTL EOT > # Sectors Per Side SC & # Sectors Remaining AND EOT & # Sectors Per Side SC > # Sectors Remaining OR EOT > # Sectors Per Side Success Termination Result Phase Valid Unsuccessful Termination Result Phase Invalid Successful Termination Result Phase Valid Unsuccessful Termination Result Phase Invalid Successful Termination Result Phase Valid Unsuccessful Termination Result Phase Invalid Successful Termination Result Phase Valid Unsuccessful Termination Result Phase Invalid
Note: If MT is set to "1" and the SC value is greater than the number of remaining formatted sectors on Side 0, verifying will continue on Side 1 of the disk. Format A Track The Format command allows an entire track to be formatted. After a pulse from the IDX pin is detected, the FDC starts writing data on the disk including gaps, address marks, ID fields, and data fields per the IBM System 34 or 3740 format (MFM or FM respectively). The particular values that will be written to the gap and data field are controlled by the values programmed into N, SC, GPL, and D which are specified by the host during the command phase. The data field of the sector is filled with the data byte specified by D. The ID field for each sector is supplied by the host; that is, four data bytes per sector are needed by the FDC for C, H, R, and N (cylinder, head, sector number and sector size respectively). After formatting each sector, the host must send new values for C, H, R and N to the FDC for the next sector on the track. The R value (sector number) is the only value that must be changed by the host after each sector is formatted. This allows the disk to be formatted with nonsequential sector addresses (interleaving). This incrementing and formatting continues for the whole track until the FDC encounters a pulse on the IDX pin again and it terminates the command. Table 33 contains typical values for gap fields which are dependent upon the size of the sector and the number of sectors on each track. Actual values can vary due to drive electronics.
SMSC DS - FDC37N958FR
Page 68
Rev. 09/01/99
Table 32 - Diskette Format Fields SYSTEM 34 (DOUBLE DENSITY) FORMAT
GAP4a 80x 4E SYNC 12x 00 IAM GAP1 SYNC 50x 12x 4E 00 IDAM C Y L H D S E C N O C GAP2 SYNC R 22x 12x C 4E 00 DATA AM C DATA R C GAP3 GAP 4b
3x FC C2
3x FE A1
3x FB A1 F8
SYSTEM 3740 (SINGLE DENSITY) FORMAT
GAP4a 40x FF SYNC 6x 00 IAM GAP1 SYNC 26x 6x FF 00 IDAM C Y L H D S E C N O C GAP2 SYNC R 11x 6x C FF 00 DATA AM C DATA R C GAP3 GAP 4b
FC
FE
FB or F8
PERPENDICULAR FORMAT
GAP4a 80x 4E SYNC 12x 00 IAM GAP1 SYNC 50x 12x 4E 00 IDAM C Y L H D S E C N O C GAP2 SYNC R 41x 12x C 4E 00 DATA AM C DATA R C GAP3 GAP 4b
3x FC C2
3x FE A1
3x FB A1 F8
SMSC DS - FDC37N958FR
Page 69
Rev. 09/01/99
FORMAT
Table 33 - Typical Values for Formatting SECTOR SIZE N SC 128 128 512 1024 2048 4096 ... 256 256 512* 1024 2048 4096 ... 128 256 512 256 512** 1024 00 00 02 03 04 05 ... 01 01 02 03 04 05 ... 0 1 2 1 2 3 12 10 08 04 02 01 12 10 09 04 02 01 0F 09 05 0F 09 05
GPL1 07 10 18 46 C8 C8 0A 20 2A 80 C8 C8 07 0F 1B 0E 1B 35
GPL2 09 19 30 87 FF FF 0C 32 50 F0 FF FF 1B 2A 3A 36 54 74
FM 5.25" Drives
MFM
3.5" Drives
FM
MFM
GPL1 = suggested GPL values in Read and Write commands to avoid splice point between data field and ID field of contiguous sections. GPL2 = suggested GPL value in Format A Track command. *PC/AT values (typical) **PS/2 values (typical). Applies with 1.0 MB and 2.0 MB drives. Note: All values except sector size are in hex.
SMSC DS - FDC37N958FR
Page 70
Rev. 09/01/99
FDC CONTROL COMMANDS
Control commands differ from the other commands in that no data transfer takes place. Three commands generate an interrupt when complete: Read ID, Recalibrate, and Seek. The other control commands do not generate an interrupt. Read ID The Read ID command is used to find the present position of the recording heads. The FDC stores the values from the first ID field it is able to read into its registers. If the FDC does not find an ID address mark on the diskette after the second occurrence of a pulse on the nINDEX pin, it then sets the IC code in Status Register 0 to "01" (abnormal termination), sets the MA bit in Status Register 1 to "1", and terminates the command. The following commands will generate an interrupt upon completion. They do not return any result bytes. It is highly recommended that control commands be followed by the Sense Interrupt Status command. Otherwise, valuable interrupt status information will be lost. Recalibrate This command causes the read/write head within the FDC to retract to the track 0 position. The FDC clears the contents of the PCN counter and checks the status of the nTR0 pin from the FDD. As long as the nTR0 pin is low, the DIR pin remains 0 and step pulses are issued. When the nTR0 pin goes high, the SE bit in Status Register 0 is set to "1" and the command is terminated. If the nTR0 pin is still low after 79 step pulses have been issued, the FDC sets the SE and the EC bits of Status Register 0 to "1" and terminates the command. Disks capable of handling more than 80 tracks per side may require more than one Recalibrate command to return the head back to physical Track 0. The Recalibrate command does not have a result phase. The Sense Interrupt Status command must be issued after the Recalibrate command to effectively terminate it and to provide verification of the head position (PCN). During the command
phase of the recalibrate operation, the FDC is in the BUSY state, but during the execution phase it is in a NON-BUSY state. At this time, another Recalibrate command may be issued, and in this manner parallel Recalibrate operations may be done on up to four drives at once. Upon power up, the software must issue a Recalibrate command to properly initialize all drives and the controller. Seek The read/write head within the drive is moved from track to track under the control of the Seek command. The FDC compares the PCN, which is the current head position, with the NCN and performs the following operation if there is a difference: PCN < NCN: Direction signal to drive set to "1" (step in) and issues step pulses. PCN > NCN: Direction signal to drive set to "0" (step out) and issues step pulses. The rate at which step pulses are issued is controlled by SRT (Stepping Rate Time) in the Specify command. After each step pulse is issued, NCN is compared against PCN, and when NCN = PCN the SE bit in Status Register 0 is set to "1" and the command is terminated. During the command phase of the seek or recalibrate operation, the FDC is in the BUSY state, but during the execution phase it is in the NON-BUSY state. At this time, another Seek or
SMSC DS - FDC37N958FR
Page 71
Rev. 09/01/99
Recalibrate command may be issued, and in this manner, parallel seek operations may be done on up to four drives at once. Note that if implied seek is not enabled, the read and write commands should be preceded by: 1. 2. 3. 4. Seek command - Step to the proper track Sense Interrupt Status command - Terminate the Seek command Read ID - Verify head is on proper track Issue Read/Write command.
Sense Interrupt Status An interrupt signal on the FDC's IRQ pin is generated by the FDC for one of the following reasons: 1. Upon entering the Result Phase of: A. Read Data command B. Read A Track command C. Read ID command D. Read Deleted Data command E. Write Data command F. Format A Track command G. Write Deleted Data command H. Verify command 2. End of Seek, Relative Seek, or Recalibrate command 3. FDC requires a data transfer during the execution phase in the non-DMA mode The Sense Interrupt Status command resets the interrupt signal and, via the IC code and SE bit of Status Register 0, identifies the cause of the interrupt.
The Seek command does not have a result phase. Therefore, it is highly recommended that the Sense Interrupt Status command be issued after the Seek command to terminate it and to provide verification of the head position (PCN). The H bit (Head Address) in ST0 will always return to a "0". When exiting POWERDOWN mode, the FDC clears the PCN value and the status information to zero. Prior to issuing the POWERDOWN command, it is highly recommended that the user service all pending interrupts through the Sense Interrupt Status command.
Table 34 - Interrupt Identification SE IC INTERRUPT DUE TO 0 1 1 11 00 01 Polling Normal termination of Seek or Recalibrate command Abnormal termination of Seek or Recalibrate command the head position (PCN). The H (Head Address) bit in ST0 will always return a "0". If a Sense Interrupt Status is not issued, the drive will continue to be BUSY and may affect the operation of the next command.
The Seek, Relative Seek, and Recalibrate commands have no result phase. The Sense Interrupt Status command must be issued immediately after these commands to terminate them and to provide verification of
SMSC DS - FDC37N958FR
Page 72
Rev. 09/01/99
Sense Drive Status Sense Drive Status obtains drive status information. It has no execution phase and goes directly to the result phase from the command phase. Status Register 3 contains the drive status information. Specify The Specify command sets the initial values for each of the three internal times. The HUT (Head Unload Time) defines the time from the end of the
execution phase of one of the read/write commands to the head unload state. The SRT (Step Rate Time) defines the time interval between adjacent step pulses. Note that the spacing between the first and second step pulses may be shorter than the remaining step pulses. The HLT (Head Load Time) defines the time between when the Head Load signal goes high and the read/write operation starts. The values change with the data rate speed selection and are documented in table 35 - Drive Control Delays (ms). The values are the same for MFM and FM.
Table 35 - Drive Control Delays(ms) HUT SRT 2M 0 1 .. E F 64 4 .. 56 60 1M 128 8 .. 112 120 500K 256 16 .. 224 240 300K 426 26.7 .. 373 400 250K 512 32 .. 448 480 2M 4 3.75 .. 0.5 0.25 1M 8 7.5 .. 1 0.5 500K 16 15 .. 2 1 300K 26.7 25 .. 3.33 1.67 250K 32 30 .. 4 2
HLT 2M 00 01 02 .. 7F 7F 64 0.5 1 .. 63 63.5 1M 128 1 2 .. 126 127 500K 256 2 4 .. 252 254 300K 426 3.3 6.7 .. 420 423 250K 512 4 8 . 504 508
The choice of DMA or non-DMA operations is made by the ND bit. When this bit is "1", the nonDMA mode is selected, and when ND is "0", the DMA mode is selected. In DMA mode, data
transfers are signalled by the FDC's DRQ pin. Non-DMA mode uses the RQM bit and the FDC's IRQ pin to signal data transfers.
SMSC DS - FDC37N958FR
Page 73
Rev. 09/01/99
Configure The Configure command is issued to select the special features of the FDC. A Configure command need not be issued if the default values of the FDC meet the system requirements. Configure Default Values: EIS - No Implied Seeks EFIFO - FIFO Disabled POLL - Polling Enabled FIFOTHR - FIFO Threshold Set to 1 Byte PRETRK - Pre-Compensation Set to Track 0 EIS - Enable Implied Seek. When set to "1", the FDC will perform a Seek operation before executing a read or write command. Defaults to no implied seek. EFIFO - A "1" disables the FIFO (default). This means data transfers are asked for on a byte-bybyte basis. Defaults to "1", FIFO disabled. The threshold defaults to "1". POLL - Disable polling of the drives. Defaults to "0", polling enabled. When enabled, a single interrupt is generated after a reset. No polling is performed while the drive head is loaded and the head unload delay has not expired. FIFOTHR - The FIFO threshold in the execution phase of read or write commands. This is programmable from 1 to 16 bytes. Defaults to one byte. A "00" selects one byte; "0F" selects 16 bytes. PRETRK - Pre-Compensation Start Track Number. Programmable from track 0 to 255. Defaults to track 0. A "00" selects track 0; "FF" selects track 255.
Version The Version command checks to see if the controller is an enhanced type or the older type (765A). A value of 90 H is returned as the result byte. Relative Seek The command is coded the same as for Seek, except for the MSB of the first byte and the DIR bit. DIR ACTION 0 Step Head Out 1 Step Head In DIR RCN Head Step Direction Control Relative Cylinder Number that determines how many tracks to step the head in or out from the current track number.
The Relative Seek command differs from the Seek command in that it steps the head the absolute number of tracks specified in the command instead of making a comparison against an internal register. The Seek command is good for drives that support a maximum of 256 tracks. Relative Seeks cannot be overlapped with other Relative Seeks. Only one Relative Seek can be active at a time. Relative Seeks may be overlapped with Seeks and Recalibrates. Bit 4 of Status Register 0 (EC) will be set if Relative Seek attempts to step outward beyond Track 0. As an example, assume that a floppy drive has 300 useable tracks. The host needs to read track 300 and the head is on any track (0-255). If a Seek command is issued, the head will stop at track 255. If a Relative Seek command is issued, the FDC will move the head the specified number of tracks, regardless of the internal cylinder position register (but will increment the register). If the head was on track 40 (d), the maximum track that the FDC could position the head on using Relative Seek will be 295 (D), the initial track + 255 (D). The maximum count that the head can be moved with a single Relative Seek command is 255 (D).
SMSC DS - FDC37N958FR
Page 74
Rev. 09/01/99
The internal register, PCN, will overflow as the cylinder number crosses track 255 and will contain 39 (D). The resulting PCN value is thus (RCN + PCN) mod 256. Functionally, the FDC starts counting from 0 again as the track number goes above 255 (D). It is the user's responsibility to compensate FDC functions (precompensation track number) when accessing tracks greater than 255. The FDC does not keep track that it is working in an "extended track area" (greater than 255). Any command issued will use the current PCN value except for the Recalibrate command, which only looks for the TRACK0 signal. Recalibrate will return an error if the head is farther than 79 due to its limitation of issuing a maximum of 80 step pulses. The user simply needs to issue a second Recalibrate command. The Seek command and implied seeks will function correctly within the 44 (D) track (299-255) area of the "extended track area". It is the user's responsibility not to issue a new track position that will exceed the maximum track that is present in the extended area. To return to the standard floppy range (0-255) of tracks, a Relative Seek should be issued to cross the track 255 boundary. A Relative Seek can be used instead of the normal Seek, but the host is required to calculate the difference between the current head location and the new (target) head location. This may require the host to issue a Read ID command to ensure that the head is physically on the track that software assumes it to be. Different FDC commands will return different cylinder results which may be difficult to keep track of with software without the Read ID command. Perpendicular Mode The Perpendicular Mode command should be issued prior to executing Read/Write/Format commands that access a disk drive with perpendicular recording capability. With this command, the length of the Gap2 field and VCO enable timing can be altered to accommodate the unique requirements of these drives. Table 36 describes the effects of the WGATE and GAP bits for the Perpendicular Mode command. Upon a
reset, the FDC will default to the conventional mode (WGATE = 0, GAP = 0). Selection of the 500 Kbps and 1 Mbps perpendicular modes is independent of the actual data rate selected in the Data Rate Select Register. The user must ensure that these two data rates remain consistent. The Gap2 and VCO timing requirements for perpendicular recording type drives are dictated by the design of the read/write head. In the design of this head, a pre-erase head precedes the normal read/write head by a distance of 200 micrometers. This works out to about 38 bytes at a 1 Mbps recording density. Whenever the write head is enabled by the Write Gate signal, the preerase head is also activated at the same time. Thus, when the write head is initially turned on, flux transitions recorded on the media for the first 38 bytes will not be preconditioned with the preerase head since it has not yet been activated. To accommodate this head activation and deactivation time, the Gap2 field is expanded to a length of 41 bytes. The format field illustrates the change in the Gap2 field size for the perpendicular format. On the read back by the FDC, the controller must begin synchronization at the beginning of the sync field. For the conventional mode, the internal PLL VCO is enabled (VCOEN) approximately 24 bytes from the start of the Gap2 field. But, when the controller operates in the 1 Mbps perpendicular mode (WGATE = 1, GAP = 1), VCOEN goes active after 43 bytes to accommodate the increased Gap2 field size. For both cases, and approximate two-byte cushion is maintained from the beginning of the sync field for the purposes of avoiding write splices in the presence of motor speed variation. For the Write Data case, the FDC activates Write Gate at the beginning of the sync field under the conventional mode. The controller then writes a new sync field, data address mark, data field, and CRC. With the pre-erase head of the perpendicular drive, the write head must be activated in the Gap2 field to insure a proper write of the new sync field. For the 1 Mbps perpendicular mode (WGATE = 1, GAP = 1), 38 bytes will be written in the Gap2 space. Since the
SMSC DS - FDC37N958FR
Page 75
Rev. 09/01/99
bit density is proportional to the data rate, 19 bytes will be written in the Gap2 field for the 500 Kbps perpendicular mode (WGATE = 1, GAP =0). It should be noted that none of the alterations in Gap2 size, VCO timing, or Write Gate timing affect normal program flow. The information provided here is just for background purposes and is not needed for normal operation. Once the Perpendicular Mode command is invoked, FDC software behavior from the user standpoint is unchanged. The perpendicular mode command is enhanced to allow specific drives to be designated Perpendicular recording drives. This enhancement allows data transfers between Conventional and Perpendicular drives without having to issue Perpendicular mode commands between the accesses of the different drive types, nor having to change write pre-compensation values. When both GAP and WGATE bits of the PERPENDICULAR MODE COMMAND are both programmed to "0" (Conventional mode), then D0, D1, D2, D3, and D4 can be programmed independently to "1" for that drive to be set automatically to Perpendicular mode.
In this mode the following set of conditions also apply: 1. The GAP2 written to a perpendicular drive during a write operation will depend upon the programmed data rate. 2. The write pre-compensation given to a perpendicular mode drive will be 0ns. 3. For D0-D3 programmed to "0" for conventional mode drives any data written will be at the currently programmed write precompensation. Note: Bits D0-D3 can only be overwritten when OW is programmed as a "1". If either GAP or WGATE is a "1" then D0-D3 are ignored. Software and hardware resets have the following effect on the PERPENDICULAR MODE COMMAND: 1. "Software" resets (via the DOR or DSR registers) will only clear GAP and WGATE bits to "0". D0-D3 are unaffected and retain their previous value. 2. "Hardware" resets will clear all bits (GAP, WGATE and D0-D3) to "0", i.e all conventional mode.
SMSC DS - FDC37N958FR
Page 76
Rev. 09/01/99
Table 36 - Effects of WGATE and GAP Bits LENGTH OF GAP2 PORTION OF GAP 2 WRITTEN BY WGATE GAP MODE FORMAT FIELD WRITE DATA OPERATION 22 Bytes 0 Bytes 0 0 Conventional 22 Bytes 19 Bytes 0 1 Perpendicular (500 Kbps) 22 Bytes 0 Bytes Reserved 1 0 (Conventional) Perpendicular 41 Bytes 38 Bytes 1 1 (1 Mbps) LOCK In order to protect systems with long DMA latencies against older application software that can disable the FIFO the LOCK Command has been added. This command should only be used by the FDC routines, and application software should refrain from using it. If an application calls for the FIFO to be disabled then the CONFIGURE command should be used. The LOCK command defines whether the EFIFO, FIFOTHR, and PRETRK parameters of the CONFIGURE command can be RESET by the DOR and DSR registers. When the LOCK bit is set to logic "1" all subsequent "software RESETS by the DOR and DSR registers will not change the previously set parameters to their default values. All "hardware" RESET from the RESET pin will set the LOCK bit to logic "0" and return the EFIFO, FIFOTHR, and PRETRK to their default values. A status byte is returned immediately after issuing a a LOCK command. This byte reflects the value of the LOCK bit set by the command byte. ENHANCED DUMPREG The DUMPREG command is designed to support system run-time diagnostics and application software development and debug. To accommodate the LOCK command and the enhanced PERPENDICULAR MODE command the eighth byte of the DUMPREG command has been modified to contain the additional data from these two commands. COMPATIBILITY The FDC37N958FR was designed with software compatibility in mind. It is a fully backwardscompatible solution with the older generation 765A/B disk controllers. The FDC also implements on-board registers for compatibility with the PS/2, as well as PC/AT and PC/XT, FDC subsystems. After a hardware reset of the FDC, all registers, functions and enhancements default to a PC/AT, PS/2 or PS/2 Model 30 compatible operating mode, depending on how the IDENT and MFM bits are configured by the system BIOS. Parallel Port FDC Refer to the the Parallel Port Section for details. Hot Swappable FDD Capability The FDC output pins will tri-state whenever the FDC Logical Device is powered-down or not activated. In addition setting bit 7 of the FDD Mode Configuration register (LD0_CRF0) will tristate the FDC output pins. Bit 7 only affects the standard FDC interface, it has no effect on the Parallel Port Floppy Interface.
SMSC DS - FDC37N958FR
Page 77
Rev. 09/01/99
The following table illustrates the state of the FDC and Parallel Port FDC pins for combinations of 1) the FDC Output Control bit; FDD MODE REGISTER, BIT[7] X X 0 1 ACTIVATE BIT 0 1 1 1
2) the Activate bit; and 3) the FDC powerdown state.
FDC IN POWER DOWN X Y N N
FDC PINS Hi-Z Hi-Z Active Hi-Z
PARALLEL PORT FDC PINS Hi-Z Hi-Z Active Active
When the FDC is disabled, powered down or inactive the FDC output pins will tri-state allowing `hot-swapping' of the Floppy Disk Drive. MECHANISM TriState
The following table lists the five control/configuration mechanisms that power down or deactivate the FDC logical device. FDC OUTPUT PINS STATE Tri-State Tri-State Tri-State (Note 1)
Tri-State (Note 2)
FDC Logical Dev Activate bit =0: FDC LD deactivated =1: FDC LD activated Refer to the description of the FDC Logical Device Configuration register 0x30 in the Configuration section of the Orion Specification. FDC Logical Dev Base Address 0x100 < Base < 0x0FF8: FDC LD Base Address Valid. 0xFFF < Base < 0x100: FDC LD Base Address Invalid. Refer to the description of the FDC Base I/O Address registers in the Configuration section of the Orion Specification. GCR 0x22 bit-0 (FDC Power) =0: Power Off =1: Power On Refer to the description of the Global Config Register 0x22 in the Configuration section of the Orion Specification. DSR, bit-6 (pwr down) =0: Normal Run =1: Manual Pwr down Refer to the description of the DSR in the FDC section of any SMSC Super or Ultra I/O data sheet.
0
X
1
1
1
X
INVALID BASE ADDRESS
VALID BASE ADDRESS
VALID BASE ADDRESS
VALID BASE ADDRESS
X
X
0
1
1
X
X
X
1
0
SMSC DS - FDC37N958FR
Page 78
Rev. 09/01/99
MECHANISM FDC OUTPUT PINS STATE X X X X 1 GCR 0x23 bit-0 (FDC auto power management) =1: Pwr Mngnt on =0: Pwr Mngnt off Refer to the description of the Global Config Register 0x23 in the Configuration section of the Orion Specification. Note: FDC Output pins = nWDATA, DRVDEN0, nHDSELm nWGATE, nDIR, nSTEP, nDS1, nDS0, nMTR0, nMTR1. Note1: DSR pwr down overrides auto pwr down. Note 2: Outputs tri-state only if all of the required auto power down conditions are met, otherwise outputs are active. See Auto Power Management Section of the FDC37C93x Data Sheet.
SMSC DS - FDC37N958FR
Page 79
Rev. 09/01/99
SERIAL PORT (UART)
The FDC37N958FR incorporates two full function UARTs. They are compatible with the NS16450, the 16450 ACE registers and the NS16550A. The UARTS perform serial-to-parallel conversion on received characters and parallel-to-serial conversion on transmit characters. The data rates are independently programmable from 460.8K baud down to 50 baud. The character options are programmable for 1 start; 1, 1.5 or 2 stop bits; even, odd, sticky or no parity; and prioritized interrupts. The UARTs each contain a programmable baud rate generator that is capable of dividing the input clock or crystal by a number from 1 to 65535. The UARTs are also capable of supporting the MIDI data rate. Refer to the Configuration Registers for information on disabling, power down and changing the base address of the UARTs. The interrupt from a UART is enabled by programming OUT2 of that UART to a logic "1". OUT2 being a logic "0" disables that UART's interrupt. The second UART also supports IrDA, HP-SIR and ASK-IR infrared modes of operation.
REGISTER DESCRIPTION
Addressing of the accessible registers of the Serial Port is shown below. The base addresses of the serial ports are defined by the configuration registers (see Configuration section). The Serial Port registers are located at sequentially increasing addresses above these base addresses. The FDC37N958FR contains two serial ports, each of which contain a register set as described below.
Table 37 - Addressing the Serial Port
DLAB* 0 0 0 X X X X X X X 1 1 A2 0 0 0 0 0 0 1 1 1 1 0 0 A1 0 0 0 1 1 1 0 0 1 1 0 0 A0 0 0 1 0 0 1 0 1 0 1 0 1 REGISTER NAME Receive Buffer (read) Transmit Buffer (write) Interrupt Enable (read/write) Interrupt Identification (read) FIFO Control (write) Line Control (read/write) Modem Control (read/write) Line Status (read/write) Modem Status (read/write) Scratchpad (read/write) Divisor LSB (read/write) Divisor MSB (read/write
Note: DLAB is Bit 7 of the Line Control Register
SMSC DS - FDC37N958FR
Page 80
Rev. 09/01/99
The following section describes the operation of the registers. RECEIVE BUFFER REGISTER (RB) Address Offset = 0H, DLAB = 0, READ ONLY This register holds the received incoming data byte. Bit 0 is the least significant bit, which is transmitted and received first. Received data is double buffered; this uses an additional shift register to receive the serial data stream and convert it to a parallel 8 bit word which is transferred to the Receive Buffer register. The shift register is not accessible. TRANSMIT BUFFER REGISTER (TB) Address Offset = 0H, DLAB = 0, WRITE ONLY This register contains the data byte to be transmitted. The transmit buffer is double buffered, utilizing an additional shift register (not accessible) to convert the 8 bit data word to a serial format. This shift register is loaded from the Transmit Buffer when the transmission of the previous byte is complete. INTERRUPT ENABLE REGISTER (IER) Address Offset = 1H, DLAB = 0, READ/WRITE The lower four bits of this register control the enables of the five interrupt sources of the Serial Port interrupt. It is possible to totally disable the interrupt system by resetting bits 0 through 3 of this register. Similarly, setting the appropriate bits of this register to a high, selected interrupts can be enabled. Disabling the interrupt system inhibits the Interrupt Identification Register and disables any Serial Port interrupt out of the FDC37N958FR. All other system functions operate in their normal manner, including the Line Status and MODEM Status Registers. The contents of the Interrupt Enable Register are described below.
BIT 0 This bit enables the Received Data Available Interrupt (and timeout interrupts in the FIFO mode) when set to logic "1". BIT 1 This bit enables the Transmitter Holding Register Empty Interrupt when set to logic "1". BIT 2 This bit enables the Received Line Status Interrupt when set to logic "1". The error sources causing the interrupt are Overrun, Parity, Framing and Break. The Line Status Register must be read to determine the source. BIT 3 This bit enables the MODEM Status Interrupt when set to logic "1". This is caused when one of the Modem Status Register bits changes state. BITS 4 - 7 These bits are always logic "0". FIFO CONTROL REGISTER (FCR) Address Offset = 2H, DLAB = X, WRITE This is a write only register at the same location as the IIR. This register is used to enable and clear the FIFOs, set the RCVR FIFO trigger level. Note: DMA is not supported. BIT 0 Setting this bit to a logic "1" enables both the XMIT and RCVR FIFOs. Clearing this bit to a logic "0" disables both the XMIT and RCVR FIFOs and clears all bytes from both FIFOs. When changing from FIFO Mode to non-FIFO (16450) mode, data is automatically cleared from the FIFOs. This bit must be a 1 when other bits in this register are written to or they will not be properly programmed.
SMSC DS - FDC37N958FR
Page 81
Rev. 09/01/99
BIT 1 Setting this bit to a logic "1" clears all bytes in the RCVR FIFO and resets its counter logic to "0". The shift register is not cleared. This bit is selfclearing. BIT 2 Setting this bit to a logic "1" clears all bytes in the XMIT FIFO and resets its counter logic to "0". The shift register is not cleared. This bit is selfclearing.
BIT 3 Writing to this bit has no effect on the operation of the UART. The RXRDY and TXRDY pins are not available on this chip. BITS 4 and 5 Reserved BITS 6 and 7 These bits are used to set the trigger level for the RCVR FIFO interrupt.
RCVR FIFO BIT 7 BIT 6 TRIGGER LEVEL (BYTES) 0 0 1 0 1 1 1 0 1 4 8 14
SMSC DS - FDC37N958FR
Page 82
Rev. 09/01/99
INTERRUPT IDENTIFICATION REGISTER (IIR) Address Offset = 2H, DLAB = X, READ By accessing this register, the host CPU can determine the highest priority interrupt and its source. Four levels of priority interrupt exist. They are in descending order of priority: 1. Receiver Line Status (highest priority) 2. Received Data Ready 3. Transmitter Holding Register Empty 4. MODEM Status (lowest priority) Information indicating that a prioritized interrupt is pending and the source of that interrupt is stored in the Interrupt Identification Register (refer to Interrupt Control Table). When the CPU accesses the IIR, the Serial Port freezes all interrupts and indicates the highest priority pending interrupt to the CPU. During this CPU access, even if the Serial Port records new interrupts, the current indication does not change until access is completed. The contents of the IIR are described below.
BIT 0 This bit can be used in either a hardwired prioritized or polled environment to indicate whether an interrupt is pending. When bit 0 is a logic "0", an interrupt is pending and the contents of the IIR may be used as a pointer to the appropriate internal service routine. When bit 0 is a logic "1", no interrupt is pending. BITS 1 and 2 These two bits of the IIR are used to identify the highest priority interrupt pending as indicated by the Interrupt Control Table. BIT 3 In non-FIFO mode, this bit is a logic "0". In FIFO mode this bit is set along with bit 2 when a timeout interrupt is pending. BITS 4 and 5 These bits of the IIR are always logic "0". BITS 6 and 7 These two bits are set when the FIFO CONTROL Register bit 0 equals 1.
Table 38 - Interrupt Control Table FIFO MODE ONLY INTERRUPT IDENTIFICATION REGISTER PRIORITY LEVEL Highest
INTERRUPT SET AND RESET FUNCTIONS INTERRUPT TYPE None Receiver Line Status INTERRUPT SOURCE None Overrun Error, Parity Error, Framing Error or Break Interrupt INTERRUPT RESET CONTROL Reading the Line Status Register
BIT 3 0 0
BIT 2 0 1
BIT 1 0 1
BIT 0 1 0
SMSC DS - FDC37N958FR
Page 83
Rev. 09/01/99
FIFO MODE ONLY 0
INTERRUPT IDENTIFICATION REGISTER 1 0 0 Second
INTERRUPT SET AND RESET FUNCTIONS Received Data Available Receiver Data Available Read Receiver Buffer or the FIFO drops below the trigger level.
1
1
0
0
Second
Character Timeout Indication
Reading the No Characters Receiver Buffer Have Been Register Removed From or Input to the RCVR FIFO during the last 4 Char times and there is at least 1 char in it during this time Transmitter Holding Register Empty Reading the IIR Register (if Source of Interrupt) or Writing the Transmitter Holding Register Reading the MODEM Status Register
0
0
1
0
Third
Transmitter Holding Register Empty
0
0
0
0
Fourth
MODEM Status
Clear to Send or Data Set Ready or Ring Indicator or Data Carrier Detect
SMSC DS - FDC37N958FR
Page 84
Rev. 09/01/99
LINE CONTROL REGISTER (LCR) Address Offset = 3H, DLAB = 0, READ/WRITE This register contains the format information of the serial line. The bit definitions are: BIT 1 0 0 1 1 BIT 0 0 1 0 1
BITS 0 and 1 These two bits specify the number of bits in each transmitted or received serial character. The encoding of bits 0 and 1 is as follows:
WORD LENGTH 5 Bits 6 Bits 7 Bits 8 Bits BIT 2 This bit specifies the number of stop bits in each transmitted or received serial character. The following table summarizes the information. NUMBER OF STOP BITS 1 1.5 2 2 2
The Start, Stop and Parity bits are not included in the word length.
BIT 2 0 1 1 1 1
WORD LENGTH -5 bits 6 bits 7 bits 8 bits
Note: The receiver will ignore all stop bits beyond the first, regardless of the number used in transmitting.
SMSC DS - FDC37N958FR
Page 85
Rev. 09/01/99
BIT 3 Parity Enable bit. When bit 3 is a logic "1", a parity bit is generated (transmit data) or checked (receive data) between the last data word bit and the first stop bit of the serial data. (The parity bit is used to generate an even or odd number of 1s when the data word bits and the parity bit are summed). BIT 4 Even Parity Select bit. When bit 3 is a logic "1" and bit 4 is a logic "0", an odd number of logic "1"'s is transmitted or checked in the data word bits and the parity bit. When bit 3 is a logic "1" and bit 4 is a logic "1" an even number of bits is transmitted and checked. BIT 5 Stick Parity bit. When bit 3 is a logic "1" and bit 5 is a logic "1", the parity bit is transmitted and then detected by the receiver in the opposite state indicated by bit 4. BIT 6 Set Break Control bit. When bit 6 is a logic "1", the transmit data output (TXD) is forced to the Spacing or logic "0" state and remains there (until reset by a low level bit 6) regardless of other transmitter activity. This feature enables the Serial Port to alert a terminal in a communications system. BIT 7 Divisor Latch Access bit (DLAB). It must be set high (logic "1") to access the Divisor Latches of the Baud Rate Generator during read or write operations. It must be set low (logic "0") to access the Receiver Buffer Register, the Transmitter Holding Register, or the Interrupt Enable Register. MODEM CONTROL REGISTER (MCR) Address Offset = 4H, DLAB = X, READ/WRITE This 8 bit register controls the interface with the MODEM or data set (or device emulating a MODEM). The contents of the MODEM control register are described below. BIT 0 This bit controls the Data Terminal Ready (nDTR) output. When bit 0 is set to a logic "1", the nDTR
output is forced to a logic "0". When bit 0 is a logic "0", the nDTR output is forced to a logic "1". BIT 1 This bit controls the Request To Send (nRTS) output. Bit 1 affects the nRTS output in a manner identical to that described above for bit 0. BIT 2 This bit controls the Output 1 (OUT1) bit. This bit does not have an output pin and can only be read or written by the CPU. BIT 3 Output 2 (OUT2). This bit is used to enable an UART interrupt. When OUT2 is a logic "0", the serial port interrupt output is forced to a high impedance state - disabled. When OUT2 is a logic "1", the serial port interrupt outputs are enabled. BIT 4 This bit provides the loopback feature for diagnostic testing of the Serial Port. When bit 4 is set to logic "1", the following occur: 1. The TXD is set to the Marking State(logic "1"). 2. The receiver Serial Input (RXD) is disconnected. 3. The output of the Transmitter Shift Register is "looped back" into the Receiver Shift Register input. 4. All MODEM Control inputs (nCTS, nDSR, nRI and nDCD) are disconnected. 5. The four MODEM Control outputs (nDTR, nRTS, OUT1 and OUT2) are internally connected to the four MODEM Control inputs (nDSR, nCTS, RI, DCD).
SMSC DS - FDC37N958FR
Page 86
Rev. 09/01/99
6. The Modem Control output pins are forced inactive high. 7. Data that is transmitted is immediately received. This feature allows the processor to verify the transmit and receive data paths of the Serial Port. In the diagnostic mode, the receiver and the transmitter interrupts are fully operational. The MODEM Control Interrupts are also operational but the interrupts' sources are now the lower four bits of the MODEM Control Register instead of the MODEM Control inputs. The interrupts are still controlled by the Interrupt Enable Register. BITS 5 - 7 These bits are permanently set to logic zero. LINE STATUS REGISTER (LSR) Address Offset = 5H, DLAB = X, READ/WRITE BIT 0 Data Ready (DR). It is set to a logic "1" whenever a complete incoming character has been received and transferred into the Receiver Buffer Register or the FIFO. Bit 0 is reset to a logic "0" by reading all of the data in the Receive Buffer Register or the FIFO. BIT 1 Overrun Error (OE). Bit 1 indicates that data in the Receiver Buffer Register was not read before the next character was transferred into the register, thereby destroying the previous character. In FIFO mode, an overrunn error will occur only when the FIFO is full and the next character has been completely received in the shift register, the character in the shift register is overwritten but not transferred to the FIFO. The OE indicator is set to a logic "1" immediately upon detection of an overrun condition, and reset whenever the Line Status Register is read.
BIT 2 Parity Error (PE). Bit 2 indicates that the received data character does not have the correct even or odd parity, as selected by the even parity select bit. The PE is set to a logic "1" upon detection of a parity error and is reset to a logic "0" whenever the Line Status Register is read. In the FIFO mode this error is associated with the particular character in the FIFO it applies to. This error is indicated when the associated character is at the top of the FIFO. BIT 3 Framing Error (FE). Bit 3 indicates that the received character did not have a valid stop bit. Bit 3 is set to a logic "1" whenever the stop bit following the last data bit or parity bit is detected as a zero bit (Spacing level). The FE is reset to a logic "0" whenever the Line Status Register is read. In the FIFO mode this error is associated with the particular character in the FIFO it applies to. This error is indicated when the associated character is at the top of the FIFO. The Serial Port will try to resynchronize after a framing error. To do this, it assumes that the framing error was due to the next start bit, so it samples this 'start' bit twice and then takes in the 'data'. BIT 4 Break Interrupt (BI). Bit 4 is set to a logic "1" whenever the received data input is held in the Spacing state (logic "0") for longer than a full word transmission time (that is, the total time of the start bit + data bits + parity bits + stop bits). The BI is reset after the CPU reads the contents of the Line Status Register. In the FIFO mode this error is associated with the particular character in the FIFO it applies to. This error is indicated when the associated character is at the top of the FIFO. When break occurs only one zero character is loaded into the FIFO. Restarting after a break is received, requires the serial data (RXD) to be logic "1" for at least 1/2 bit time. Note: Bits 1 through 4 are the error conditions that produce a
SMSC DS - FDC37N958FR
Page 87
Rev. 09/01/99
Receiver Line Status Interrupt whenever any of the corresponding conditions are detected and the interrupt is enabled. BIT 5 Transmitter Holding Register Empty (THRE). Bit 5 indicates that the Serial Port is ready to accept a new character for transmission. In addition, this bit causes the Serial Port to issue an interrupt when the Transmitter Holding Register interrupt enable is set high. The THRE bit is set to a logic "1" when a character is transferred from the Transmitter Holding Register into the Transmitter Shift Register. The bit is reset to logic "0" whenever the CPU loads the Transmitter Holding Register. In the FIFO mode this bit is set when the XMIT FIFO is empty, it is cleared when at least 1 byte is written to the XMIT FIFO. Bit 5 is a read only bit. BIT 6 Transmitter Empty (TEMT). Bit 6 is set to a logic "1" whenever the Transmitter Holding Register (THR) and Transmitter Shift Register (TSR) are both empty. It is reset to logic "0" whenever either the THR or TSR contains a data character. Bit 6 is a read only bit. In the FIFO mode this bit is set whenever the THR and TSR are both empty, BIT 7 This bit is permanently set to logic "0" in the 450 mode. In the FIFO mode, this bit is set to a logic "1" when there is at least one parity error, framing error or break indication in the FIFO. This bit is cleared when the LSR is read if there are no subsequent errors in the FIFO. MODEM STATUS REGISTER (MSR) Address Offset = 6H, DLAB = X, READ/WRITE This 8 bit register provides the current state of the control lines from the MODEM (or peripheral device). In addition to this current state information, four bits of the MODEM Status Register (MSR) provide change information.
These bits are set to logic "1" whenever a control input from the MODEM changes state. They are reset to logic "0" whenever the MODEM Status Register is read. BIT 0 Delta Clear To Send (DCTS). Bit 0 indicates that the nCTS input to the chip has changed state since the last time the MSR was read. BIT 1 Delta Data Set Ready (DDSR). Bit 1 indicates that the nDSR input has changed state since the last time the MSR was read. BIT 2 Trailing Edge of Ring Indicator (TERI). Bit 2 indicates that the nRI input has changed from logic "0" to logic "1". BIT 3 Delta Data Carrier Detect (DDCD). Bit 3 indicates that the nDCD input to the chip has changed state. NOTE: Whenever bit 0, 1, 2, or 3 is set to a logic "1", a MODEM Status Interrupt is generated. BIT 4 This bit is the complement of the Clear To Send (nCTS) input. If bit 4 of the MCR is set to logic "1", this bit is equivalent to nRTS in the MCR. BIT 5 This bit is the complement of the Data Set Ready (nDSR) input. If bit 4 of the MCR is set to logic "1", this bit is equivalent to DTR in the MCR. BIT 6 This bit is the complement of the Ring Indicator (nRI) input. If bit 4 of the MCR is set to logic "1", this bit is equivalent to OUT1 in the MCR.
SMSC DS - FDC37N958FR
Page 88
Rev. 09/01/99
BIT 7 This bit is the complement of the Data Carrier Detect (nDCD) input. If bit 4 of the MCR is set to logic "1", this bit is equivalent to OUT2 in the MCR. SCRATCHPAD REGISTER (SCR) Address Offset =7H, DLAB =X, READ/WRITE This 8 bit read/write register has no effect on the operation of the Serial Port. It is intended as a scratchpad register to be used by the programmer to hold data temporarily. PROGRAMMABLE BAUD RATE GENERATOR (AND DIVISOR LATCHES DLH, DLL) The Serial Port contains a programmable Baud Rate Generator that is capable of taking any clock input (DC to 3 MHz) and dividing it by any divisor from 1 to 65535. This output frequency of the
Baud Rate Generator is 16x the Baud rate. Two 8 bit latches store the divisor in 16 bit binary format. These Divisor Latches must be loaded during initialization in order to insure desired operation of the Baud Rate Generator. Upon loading either of the Divisor Latches, a 16 bit Baud counter is immediately loaded. This prevents long counts on initial load. If a 0 is loaded into the BRG registers the output divides the clock by the number 3. If a 1 is loaded the output is the inverse of the input oscillator. If a two is loaded the output is a divide by 2 signal with a 50% duty cycle. If a 3 or greater is loaded the output is low for 2 bits and high for the remainder of the count. The input clock to the BRG is the 24 MHz crystal divided by 13, giving a 1.8462 MHz clock. Table 39 shows the baud rates possible with a 1.8462 MHz crystal.
SMSC DS - FDC37N958FR
Page 89
Rev. 09/01/99
DESIRED BAUD RATE 50 75 110 134.5 150 300 600 1200 1800 2000 2400 3600 4800 7200 9600 19200 38400 57600 115200 230400 460800
Table 39 - UART Baud Rates DIVISOR USED TO PERCENT ERROR DIFFERENCE GENERATE 16X CLOCK BETWEEN DESIRED AND ACTUAL* 2304 1536 1047 857 768 384 192 96 64 58 48 32 24 16 12 6 3 2 1 32770 32769 0.001 0.004 0.005 0.030 0.16 0.16 0.16 0.16
CRxx: BIT 7 OR 6 X X X X X X X X X X X X X X X X X X X 1 1
*Note: The percentage error for all baud rates, except where indicated otherwise, is 0.2%. Baud Rates Using 1.8462 MHz Clock for <=38.4; Using 1.843 MHz Clock for 115.2k; Using 3.6864 MHz Clock for 230.4k; Using 7.3728 MHz Clock for 460.8k
SMSC DS - FDC37N958FR
Page 90
Rev. 09/01/99
FIFO INTERRUPT MODE OPERATION
When the RCVR FIFO and receiver interrupts are enabled (FCR bit 0 = "1", IER bit 0 = "1"), RCVR interrupts occur as follows: The receive data available interrupt will be issued when the FIFO has reached its programmed trigger level; it is cleared as soon as the FIFO drops below its programmed trigger level. B. The IIR receive data available indication also occurs when the FIFO trigger level is reached. It is cleared when the FIFO drops below the trigger level. C. The receiver line status interrupt (IIR=06H), has higher priority than the received data available (IIR=04H) interrupt. D. The data ready bit (LSR bit 0) is set as soon as a character is transferred from the shift register to the RCVR FIFO. It is reset when the FIFO is empty. When RCVR FIFO and receiver interrupts are enabled, RCVR FIFO timeout interrupts occur as follows: A. A FIFO timeout interrupt occurs if all the following conditions exist: ! at least one character is in the FIFO ! The most recent serial character received was longer than 4 continuous character times ago. (If 2 stop bits are programmed, the second one is included in this time delay.) ! The most recent CPU read of the FIFO was longer than 4 continuous character times ago. This will cause a maximum character received to interrupt issued delay of 160 msec at 300 BAUD with a 12 bit character. A.
B. Character times are calculated by using the RCLK input for a clock signal (this makes the delay proportional to the baudrate). C. When a timeout interrupt has occurred it is cleared and the timer reset when the CPU reads one character from the RCVR FIFO. D. When a timeout interrupt has not occurred the timeout timer is reset after a new character is received or after the CPU reads the RCVR FIFO. When the XMIT FIFO and transmitter interrupts are enabled (FCR bit 0 = "1", IER bit 1 = "1"), XMIT interrupts occur as follows: A. The transmitter holding register interrupt (02H) occurs when the XMIT FIFO is empty; it is cleared as soon as the transmitter holding register is written to (1 of 16 characters may be written to the XMIT FIFO while servicing this interrupt) or the IIR is read. B. The transmitter FIFO empty indications will be delayed 1 character time minus the last stop bit time whenever the following occurs: THRE=1 and there have not been at least two bytes at the same time in the transmitter FIFO since the last THRE=1. The transmitter interrupt after changing FCR0 will be immediate, if it is enabled. Character timeout and RCVR FIFO trigger level interrupts have the same priority as the current received data available interrupt; XMIT FIFO empty has the same priority as the current transmitter holding register empty interrupt.
FIFO POLLED MODE OPERATION
With FCR bit 0 = "1" resetting IER bits 0, 1, 2 or 3 or all to zero puts the UART in the FIFO Polled Mode of operation. Since the RCVR and XMITTER are controlled separately, either one or both can be in the polled mode of operation.
SMSC DS - FDC37N958FR
Page 91
Rev. 09/01/99
In this mode, the user's program will check RCVR and XMITTER status via the LSR. LSR definitions for the FIFO Polled Mode are as follows: ! Bit 0=1 as long as there is one byte in the RCVR FIFO. ! Bits 1 to 4 specify which error(s) have occurred. Character error status is handled the same way as when in the interrupt mode, the IIR is not affected since EIR bit 2=0. ! Bit 5 indicates when the XMIT FIFO is empty. ! Bit 6 indicates that both the XMIT FIFO and shift register are empty.
!
Bit 7 indicates whether there are any errors in the RCVR FIFO.
There is no trigger level reached or timeout condition indicated in the FIFO Polled Mode, however, the RCVR and XMIT FIFOs are still fully capable of holding characters. Effect Of The Reset on Register File The Reset Function Table (Table 40) details the effect of Vcc2 POR or nRESET_OUT on each of the registers of the Serial Port.
SMSC DS - FDC37N958FR
Page 92
Rev. 09/01/99
REGISTER/SIGNAL Interrupt Enable Register Interrupt Identification Reg. FIFO Control Line Control Reg. MODEM Control Reg. Line Status Reg. MODEM Status Reg. TXD1, TXD2 INTRPT (RCVR errs) INTRPT (RCVR Data Ready) INTRPT (THRE) OUT2B RTSB DTRB OUT1B RCVR FIFO XMIT FIFO
Table 40 - Reset Function Table RESET CONTROL RESET RESET RESET RESET RESET RESET RESET RESET RESET/Read LSR RESET/Read RBR RESET/ReadIIR/Write THR RESET RESET RESET RESET RESET/ FCR1*FCR0/_FCR0 RESET/ FCR1*FCR0/_FCR0
RESET STATE
All bits low Bit 0 is high; Bits 1 - 7 low All bits low All bits low All bits low All bits low except 5, 6 high Bits 0 - 3 low; Bits 4 - 7 input High Low Low Low High High High High All Bits Low All Bits Low
SMSC DS - FDC37N958FR
Page 93
Rev. 09/01/99
REGISTER ADDRESS* ADDR = 0 DLAB = 0 ADDR = 0 DLAB = 0 ADDR = 1 DLAB = 0
Table 41 - Register Summary for an Individual UART Channel REGISTER SYMBOL REGISTER NAME BIT 0 Receive Buffer Register (Read Only) RBR Data Bit 0 (Note 1) Transmitter Holding Register (Write THR Data Bit 0 Only) Interrupt Enable Register IER Enable Received Data Available Interrupt (ERDAI) Interrupt Ident. Register (Read Only) IIR "0" if Interrupt Pending FIFO Enable Word Length Select Bit 0 (WLS0) Data Terminal Ready (DTR) Data Ready (DR) Delta Clear to Send (DCTS) Bit 0 Bit 0 Bit 8
BIT 1 Data Bit 1 Data Bit 1 Enable Transmitter Holding Register Empty Interrupt (ETHREI) Interrupt ID Bit RCVR FIFO Reset Word Length Select Bit 1 (WLS1) Request to Send (RTS)
ADDR = 2
ADDR = 2 ADDR = 3
FIFO Control Register (Write Only) Line Control Register
FCR LCR
ADDR = 4
MODEM Control Register
MCR
ADDR = 5 ADDR = 6
Line Status Register MODEM Status Register
LSR MSR
ADDR = 7 ADDR = 0 DLAB = 1 ADDR = 1 DLAB = 1
Scratch Register (Note 4) Divisor Latch (LS) Divisor Latch (MS)
SCR DDL DLM
Overrun Error (OE) Delta Data Set Ready (DDSR) Bit 1 Bit 1 Bit 9
*DLAB is Bit 7 of the Line Control Register (ADDR = 3). Note 1: Bit 0 is the least significant bit. It is the first bit serially transmitted or received. Note 2: When operating in the XT mode, this bit will be set any time that the transmitter shift register is empty.
SMSC DS - FDC37N958FR
Page 94
Rev. 09/01/99
Table 41 - Register Summary for an Individual UART Channel (continued) BIT 2 BIT 3 BIT 4 BIT 5 BIT 6 BIT 7 Data Bit 2 Data Bit 3 Data Bit 4 Data Bit 5 Data Bit 6 Data Bit 7 Data Bit 2 Enable Receiver Line Status Interrupt (ELSI) Interrupt ID Bit XMIT FIFO Reset Number of Stop Bits (STB) OUT1 (Note 3) Parity Error (PE) Data Bit 3 Enable MODEM Status Interrupt (EMSI) Interrupt ID Bit (Note 5) DMA Mode Select (Note 6) Parity Enable (PEN) OUT2 (Note 3) Framing Error (FE) Data Bit 4 0 Data Bit 5 0 Data Bit 6 0 Data Bit 7 0
0
0
Reserved
Reserved
FIFOs Enabled (Note 5) RCVR Trigger LSB Set Break
FIFOs Enabled (Note 5) RCVR Trigger MSB Divisor Latch Access Bit (DLAB) 0 Error in RCVR FIFO (Note 5) Data Carrier Detect (DCD)
Even Parity Select (EPS) Loop
Stick Parity
0
0 Transmitter Empty (TEMT) (Note 2) Ring Indicator (RI)
Trailing Edge Ring Indicator (TERI) Bit 2 Bit 2 Bit 10 Note 3: Note 4: Note 5: Note 6:
Delta Data Carrier Detect (DDCD) Bit 3 Bit 3 Bit 11
Break Transmitter Interrupt (BI) Holding Register (THRE) Clear to Data Set Send (CTS) Ready (DSR)
Bit 4 Bit 4 Bit 12
Bit 5 Bit 5 Bit 13
Bit 6 Bit 6 Bit 14
Bit 7 Bit 7 Bit 15
This bit no longer has a pin associated with it. When operating in the XT mode, this register is not available. These bits are always zero in the non-FIFO mode. Writing a one to this bit has no effect. DMA modes are not supported in this chip.
SMSC DS - FDC37N958FR
Page 95
Rev. 09/01/99
UART Register Summary Notes: *DLAB is Bit 7 of the Line Control Register (ADDR = 3). Note 1: Bit 0 is the least significant bit. It is the first bit serially transmitted or received. Note 2: When operating in the XT mode, this bit will be set any time that the transmitter shift register is empty. Note 3: This bit no longer has a pin associated with it. Note 4: When operating in the XT mode, this register is not available. Note 5: These bits are always zero in the non-FIFO mode. Note 6: Writing a one to this bit has no effect. DMA modes are not supported in this chip.
NOTES ON SERIAL PORT FIFO MODE OPERATION
GENERAL The RCVR FIFO will hold up to 16 bytes regardless of which trigger level is selected. TX AND RX FIFO OPERATION The Tx portion of the UART transmits data through TXD as soon as the CPU loads a byte into the Tx FIFO. The UART will prevent loads to the Tx FIFO if it currently holds 16 characters. Loading to the Tx FIFO will again be enabled as soon as the next character is transferred to the Tx shift register. These capabilities account for the largely autonomous operation of the Tx. The UART starts the above operations typically with a Tx interrupt. The chip issues a Tx interrupt whenever the Tx FIFO is empty and the Tx interrupt is enabled, except in the following instance. Assume that the Tx FIFO is empty and the CPU starts to load it. When the first byte enters the FIFO the Tx FIFO empty interrupt will transition from active to inactive. Depending on the execution speed of the service routine software, the UART may be able to transfer this byte from the FIFO to the shift register before the CPU loads another byte. If this happens, the Tx FIFO will be empty again and typically the UART's interrupt line would transition to the active state. This could cause a system with an interrupt
control unit to record a Tx FIFO empty condition, even though the CPU is currently servicing that interrupt. Therefore, after the first byte has been loaded into the FIFO the UART will wait one serial character transmission time before issuing a new Tx FIFO empty interrupt. This one character Tx interrupt delay will remain active until at least two bytes have been loaded into the FIFO, concurrently. When the Tx FIFO empties after this condition, the Tx interrupt will be activated without a one character delay. Rx support functions and operation are quite different from those described for the transmitter. The Rx FIFO receives data until the number of bytes in the FIFO equals the selected interrupt trigger level. At that time if Rx interrupts are enabled, the UART will issue an interrupt to the CPU. The Rx FIFO will continue to store bytes until it holds 16 of them. It will not accept any more data when it is full. Any more data entering the Rx shift register will set the Overrun Error flag. Normally, the FIFO depth and the programmable trigger levels will give the CPU ample time to empty the Rx FIFO before an overrun occurs. One side-effect of having a Rx FIFO is that the selected interrupt trigger level may be above the data level in the FIFO. This could occur when data at the end of the block contains fewer bytes than the trigger level. No interrupt would be issued to the CPU and the data would remain in the UART. To prevent the software from
SMSC DS - FDC37N958FR
Page 96
Rev. 09/01/99
having to check for this situation the chip incorporates a timeout interrupt. The timeout interrupt is activated when there is a least one byte in the Rx FIFO, and neither the CPU nor the Rx shift register has accessed the Rx FIFO within 4 character times of the last byte. The timeout interrupt is cleared or reset when the
CPU reads the Rx FIFO or another character enters it. These FIFO related features allow optimization of CPU/UART transactions and are especially useful given the higher baud rate capability (256 kbaud).
SMSC DS - FDC37N958FR
Page 97
Rev. 09/01/99
Infrared Communications Controller (IrCC)
The Infrared Communications Controller is fully compliant to the IrDA Specification Version 1.1 which includes data rates up to 4 Mbps to support IrDA-SIRA, IrDA-SIRB, IrDA-HDLC and IrDA-FIR modes. In addition the IrCC provides support for ASK-IR, Consumer (TV remote) IR, and RAW-IR (Host controller has direct access to the IR bit stream from/to the transceiver module). It is important to note that the IrCC block is a superset of UART2. Thus the IrCC comprises of a UART2 Asynchronous Communications Engine (ACE) and a separate Synchronous Communications Engine (SCE) to provide the full set of IR modes as well as the standard UART Com mode. The IrCC block details are fully described in SMSC's specification titled "Infrared Communications Controller". The information in this section of the specification will provide details on the integration of the FIR logic block into the FDC37N958FR. The infrared interface provides a two-way wireless communications port using infrared as a transmission medium. The IR transmission can use the standard UART2 TX and RX pins or optional IRTX2 and IRRX2 pins. These can be selected through the configuration registers. IrDA-SIR allows serial communication at baud rates up to 115K Baud. Each word is sent serially beginning with a "0" value start bit. A "0" is signaled by sending a single IR pulse at the beginning of the serial bit time. A "1" is signaled by sending no IR pulse during the bit time. Please refer to the AC timing for the parameters of these pulses and the IrDA waveform. The Amplitude Shift Keyed IR allows serial communication at baud rates up to 19.2K Baud. Each word is sent serially beginning with a "0" value start bit. A "0" is signaled by sending a 500 KHz waveform for the duration of the serial bit time. A "1" is signaled by sending no transmission the bit time. Please refer to the AC timing for the parameters of the ASK-IR waveform. If the Half Duplex option is chosen, there is a timeout when the direction of the transmission is changed. This time-out starts at the last bit transfered during a transmission and blocks the receiver input until the time-out expires. If the transmit buffer is loaded with more data before the time-out expires, the timer is restarted after the new byte is transmitted. If data is loaded into the transmit buffer while a character is being received, the transmission will not start until the time-out expires after the last receive bit has been received. If the start bit of another character is received during this time-out, the timer is restarted after the new character is received. The time-out is four character times. A character time is defined as 10 bit times regardless of the actual word length being used.
SMSC DS - FDC37N958FR
Page 98
Rev. 09/01/99
IrCC Block RAW TV ASK IrDA FIR COM G.P. Data FAST_BIT nRTS2 nCTS2 nDTR2 nDSR2 nDCD2 nRI2
FAST
HP_MODE
GPIO9_IN GPIO9_OUT 0 1 0 1
MISC7 MISC2
GPIO9
COM OUT MUX IR
TX RX TX RX TX RX
FRX_SEL
GPIO8_OUT
GPIO8
0 1 0 "FRx"
IR Data Reg bit-0
1 0 1
IRTX IRRX GPIO6
IR Data Reg bit-1
1 0
GPIO6_OUT
AUX
0 1
GPIO10_OUT "IR_MODE"
00 01 11
GPIO10
MISC[14:13] MISC[16:15]
GPIO11
M U X
GPIO[11-15]
GPIO12 GPIO13 GPIO14 GPIO15
MISC[12]
FIGURE 3 - INTEGRATION OF IrCC LOGIC INTO THE FDC37N958FR HP_MODE = (MISC[14:13] == [1:0]) | (MISC[16:15] == [1:0]) FRX_SEL = (MISC[14:13] == [1:0]) IRRX/IRTX PIN ENABLE When MISC2=0 the IRRX and IRTX pins are enabled as when UART2 (LD5) is activated or enabled and the IrCC Output Mux is set to use the IR Port, otherwise the IRTX pin is tri-stated. When MISC2=1, the IRRX and IRTX pins are always enabled as they can be bit banged through the IR Data Register, bits 1 and 0 respectively.
SMSC DS - FDC37N958FR
Page 99
Rev. 09/01/99
IR REGISTERS - LOGICAL DEVICE 5
Configuration Registers Overview In order to support the Infared Communications Controller four configuration registers are added to Logical Device 5 (commonly known as UART2). These registers consist of the
Fast IR Base I/O Address registers 0x62 and 0x63; an IrCC DMA channel select register 0x74; and an IR Half Duplex Timeout register 0xF2. Refer to the Configuration section of this specification for details. Base I/O Addresses 550 UART
Table 42 - Asynchronous Communications Engine (UART) Registers REGISTER FIXED REGISTER BASE INDEX BASE I/O RANGE OFFSETS 0x60, 0x61 [0x100:0x0FF8] +0 : RB/TB % LSB div +1 : IER % MSB div ON 8 BYTE BOUNDARIES +2 : IIR/FCR +3 : LCR +4 : MCR +5 : LSR +6 : MSR +7 : SCR Register 0x60 stores the MSB and 0x61 the LSB of the 550-UART's 16 bit Base Address.
SMSC DS - FDC37N958FR
Page 100
Rev. 09/01/99
Fast IR/USRT Table 43 - Synchronous Communications Engine (SCE) Registers REGISTER FIXED REGISTER BASE INDEX BASE I/O RANGE OFFSETS 0x62, 0x63 [0x100:0x0FF8] +0 : Register Block N, address 0 +1 : Register Block N, address 1 ON 8 BYTE BOUNDARIES +2 : Register Block N, address 2 +3 : Register Block N, address 3 +4 : Register Block N, address 4 +5 : Register Block N, address 5 +6 : Register Block N, address 6 +7 : USRT Master Control Register Register 0x60 stores the MSB and 0x61 the LSB of the 550-UART's 16 bit Base Address. Note: Refer to the Infrared Communications Controller (IrCC) Specification for register details Note: If Base I/O Address is set below 0x100 then no decode will occur. IR DMA Channels DMA channel 0, 1, 2 or 3 may be selected for use with the IRCC logic through the configuration registers of Logical Device 5. Refer to the Configuation section of this specification for further details on setting the DMA channel and to the IrCC specificaton for details on IR DMA transfers. IR IRQs The interrupt (IRQ) for the IRCC logic is selectable through the configuration registers for logical device 5. Refer to the Configuation section of this specification for further details on setting the IRQ and to the IrCC specificaton for details on IR IRQ events.
SMSC DS - FDC37N958FR
Page 101
Rev. 09/01/99
PARALLEL PORT
The FDC37N958FR incorporates an IBM XT/AT compatible parallel port. This supports the optional PS/2 type bi-directional parallel port (SPP), the Enhanced Parallel Port (EPP) and the Extended Capabilities Port (ECP) parallel port modes. Refer to the Configuration Registers for information on disabling, power down, changing the base address of the parallel port, and selecting the mode of operation. The parallel port also incorporates SMSC's ChiProtect circuitry, which prevents possible damage to the parallel port due to printer powerup. The functionality of the parallel port is achieved through the use of eight addressable ports, with their associated registers and control The bit map of these registers is: D0 D1 DATA PORT STATUS PORT CONTROL PORT EPP ADDR PORT EPP DATA PORT 0 EPP DATA PORT 1 EPP DATA PORT 2 EPP DATA PORT 3 PD0 TMOUT PD1 0 gating. The control and data port are read/write by the CPU, the status port is read/write in the EPP mode. The address map of the Parallel Port is shown below: Address Map For Parallel Port REGISTER NAME ADDRESS
DATA PORT STATUS PORT CONTROL PORT EPP ADDR PORT EPP DATA PORT 0 EPP DATA PORT 1 EPP DATA PORT 2 EPP DATA PORT 3 BASE ADDRESS + 00H BASE ADDRESS + 01H BASE ADDRESS + 02H BASE ADDRESS + 03H BASE ADDRESS + 04H BASE ADDRESS + 05H BASE ADDRESS + 06H BASE ADDRESS + 07H
D2 PD2 0 nINIT PD2 PD2 PD2 PD2 PD2
D3 PD3 nERR SLC PD3 PD3 PD3 PD3 PD3
D4 PD4 SLCT IRQE PD4 PD4 PD4 PD4 PD4
D5 PD5 PE PCD PD5 PD5 PD5 PD5 PD5
D6 PD6 nACK 0 PD6 PD6 PD6 PD6 PD6
D7 PD7 nBUSY 0 AD7 PD7 PD7 PD7 PD7
NOTE 1 1 1 2,3 2,3 2,3 2,3 2,3
STROBE AUTOFD PD0 PD0 PD0 PD0 PD0 PD1 PD1 PD1 PD1 PD1
Note 1: These registers are available in all modes. Note 2: These registers are only available in EPP mode. Note 3: For EPP mode, IOCHRDY must be connected to the ISA bus.
SMSC DS - FDC37N958FR
Page 102
Rev. 09/01/99
Table 44 - Parallel Port Connector HOST CONNECTOR 1 2-9 10 11 12 13 14 15 16 17 (1) = Compatible Mode (3) = High Speed Mode Note: For the cable interconnection required for ECP support and the Slave Connector pin numbers, refer to the IEEE P1284 D2.0 Standard, "Standard Signaling Method for a Bi-directional Parallel Peripheral Interface for Personal Computers", September 10, 1993. This document is available from the IEEE. BI-DIRECTIONAL cleared at nitialization by RESET. During a WRITE operation, the Data Register latches the contents of the data bus with the rising edge of the nIOW input. The contents of this register are buffered (non inverting) and output onto the PD0-PD7 ports. During a READ operation in SPP mode, PD0-PD7 ports are buffered (not latched) and output to the host CPU. PIN NUMBER 129 124-121, 119-116 115 114 113 112 128 127 126 125 nAck Busy PE Select nAutofd nError nInit nSelectin Intr nWait (NU) (NU) nDatastb (NU) (NU) nAddrstrb nAck Busy, PeriphAck(3) PError, nAckReverse(3) Select nAutoFd, HostAck(3) nFault(1) nPeriphRequest(3) nInit(1) nReverseRqst(3) nSelectIn(1,3) STANDARD nStrobe PData<0:7> EPP nWrite PData<0:7> nStrobe PData<0:7> ECP
IBM XT/AT COMPATIBLE, AND EPP MODES DATA PORT ADDRESS OFFSET = 00H
The Data Port is located at an offset of '00H' from the base address. The data register is
SMSC DS - FDC37N958FR
Page 103
Rev. 09/01/99
STATUS PORT ADDRESS OFFSET = 01H The Status Port is located at an offset of '01H' from the base address. The contents of this register are latched for the duration of an nIOR read cycle. The bits of the Status Port are defined as follows: BIT 0 TMOUT - TIME OUT This bit is valid in EPP mode only and indicates that a 10 usec time out has occured on the EPP bus. A logic "0" means that no time out error has occured; a logic "1" means that a time out error has been detected. This bit is cleared by a RESET. Writing a one to this bit clears the time out status bit. On a write, this bit is self clearing and does not require a write of a "0". Writing a "0" to this bit has no effect. BITS 1, 2 - are not implemented as register bits, during a read of the Printer Status Register these bits are a low level. BIT 3 nERR - nERROR The level on the nERROR input is read by the CPU as bit 3 of the Printer Status Register. A logic 0 means an error has been detected; a logic "1" means no error has been detected. BIT 4 SLCT - PRINTER SELECTED STATUS The level on the SLCT input is read by the CPU as bit 4 of the Printer Status Register. A logic "1" means the printer is on line; a logic 0 means it is not selected. BIT 5 PE - PAPER END The level on the PE input is read by the CPU as bit 5 of the Printer Status Register. A logic "1" indicates a paper end; a logic 0 indicates the presence of paper. BIT 6 nACK - nACKNOWLEDGE The level on the nACK input is read by the CPU as bit 6 of the Printer Status Register. A logic "0" means that the printer has received a character and can now accept another. A logic "1" means that it is still processing the last character or has not received the data.
BIT 7 nBUSY - nBUSY The complement of the level on the BUSY input is read by the CPU as bit 7 of the Printer Status Register. A logic "0" in this bit means that the printer is busy and cannot accept a new character. A logic "1" means that it is ready to accept the next character. CONTROL PORT ADDRESS OFFSET = 02H The Control Port is located at an offset of '02H' from the base address. The Control Register is initialized by the RESET input, bits 0 to 5 only being affected; bits 6 and 7 are hard wired low. BIT 0 STROBE - STROBE This bit is inverted and output onto the nSTROBE output. BIT 1 AUTOFD - AUTOFEED This bit is inverted and output onto the nAUTOFD output. A logic "1" causes the printer to generate a line feed after each line is printed. A logic "0" means no autofeed. BIT 2 nINIT - nINITIATE OUTPUT This bit is output onto the nINIT output without inversion. BIT 3 SLCTIN - PRINTER SELECT INPUT This bit is inverted and output onto the nSLCTIN output. A logic "1" on this bit selects the printer; a logic "0" means the printer is not selected. BIT 4 IRQE - INTERRUPT REQUEST ENABLE The interrupt request enable bit when set to a high level may be used to enable interrupt requests from the Parallel Port to the CPU. An interrupt request is generated on the IRQ port by a positive going nACK input. When the IRQE bit is programmed low the IRQ is disabled.
SMSC DS - FDC37N958FR
Page 104
Rev. 09/01/99
BIT 5 PCD - PARALLEL CONTROL DIRECTION Parallel Control Direction is not valid in printer mode. In printer mode, the direction is always out regardless of the state of this bit. In bi-directional, EPP or ECP mode, a logic 0 means that the printer port is in output mode (write); a logic "1" means that the printer port is in input mode (read). Bits 6 and 7 during a read are a low level, and cannot be written. EPP ADDRESS PORT ADDRESS OFFSET = 03H The EPP Address Port is located at an offset of '03H' from the base address. The address register is cleared at initialization by RESET. During a WRITE operation, the contents of DB0DB7 are buffered (non inverting) and output onto the PD0 - PD7 ports, the leading edge of nIOW causes an EPP ADDRESS WRITE cycle to be performed, the trailing edge of IOW latches the data for the duration of the EPP write cycle. During a READ operation, PD0-PD7 ports are read, the leading edge of IOR causes an EPP ADDRESS READ cycle to be performed and the data output to the host CPU, the deassertion of ADDRSTB latches the PData for the duration of the IOR cycle. This register is only available in EPP mode. EPP DATA PORT 0 ADDRESS OFFSET = 04H The EPP Data Port 0 is located at an offset of '04H' from the base address. The data register
is cleared at initialization by RESET. During a WRITE operation, the contents of DB0-DB7 are buffered (non inverting) and output onto the PD0-PD7 ports, the leading edge of nIOW causes an EPP DATA WRITE cycle to be performed, the trailing edge of IOW latches the data for the duration of the EPP write cycle. During a READ operation, PD0 - PD7 ports are read, the leading edge of IOR causes an EPP READ cycle to be performed and the data output to the host CPU, the deassertion of DATASTB latches the PData for the duration of the IOR cycle. This register is only available in EPP mode. EPP DATA PORT 1 ADDRESS OFFSET = 05H The EPP Data Port 1 is located at an offset of '05H' from the base address. Refer to EPP DATA PORT 0 for a description of operation. This register is only available in EPP mode. EPP DATA PORT 2 ADDRESS OFFSET = 06H The EPP Data Port 2 is located at an offset of '06H' from the base address. Refer to EPP DATA PORT 0 for a description of operation. This register is only available in EPP mode. EPP DATA PORT 3 ADDRESS OFFSET = 07H The EPP Data Port 3 is located at an offset of '07H' from the base address. Refer to EPP DATA PORT 0 for a description of operation. This register is only available in EPP mode.
SMSC DS - FDC37N958FR
Page 105
Rev. 09/01/99
EPP 1.9 OPERATION When the EPP mode is selected in the configuration register, the standard and bidirectional modes are also available. If no EPP Read, Write or Address cycle is currently executing, then the PDx bus is in the standard or bi-directional mode, and all output signals (STROBE, AUTOFD, INIT) are as set by the SPP Control Port and direction is controlled by PCD of the Control port. In EPP mode, the system timing is closely coupled to the EPP timing. For this reason, a watchdog timer is required to prevent system lockup. The timer indicates if more than 10usec have elapsed from the start of the EPP cycle (nIOR or nIOW asserted) to nWAIT being deasserted (after command). If a time-out occurs, the current EPP cycle is aborted and the time-out condition is indicated in Status bit 0. During an EPP cycle, if STROBE is active, it overrides the EPP write signal forcing the PDx bus to always be in a write mode and the nWRITE signal to always be asserted. Software Constraints Before an EPP cycle is executed, the software must ensure that the control register bit PCD is a logic "0" (i.e. a 04H or 05H should be written to the Control port). If the user leaves PCD as a logic "1", and attempts to perform an EPP write, the chip is unable to perform the write (because PCD is a logic "1") and will appear to perform an EPP read on the parallel bus, no error is indicated. EPP 1.9 Write The timing for a write operation (address or data) is shown in timing diagram EPP Write Data or Address cycle. IOCHRDY is driven active low at the start of each EPP write and is released when it has been determined that the write cycle can complete.
The write cycle can complete under the following circumstances: 1. If the EPP bus is not ready (nWAIT is active low) when nDATASTB or nADDRSTB goes active then the write can complete when nWAIT goes inactive high. If the EPP bus is ready (nWAIT is inactive high) then the chip must wait for it to go active low before changing the state of nDATASTB, nWRITE or nADDRSTB. The write can complete once nWAIT is determined inactive.
2.
Write Sequence of operation 1. 2. 3. 4. 5. 6. The host selects an EPP register, places data on the SData bus and drives nIOW active. The chip drives IOCHRDY inactive (low). If WAIT is not asserted, the chip must wait until WAIT is asserted. The chip places address or data on PData bus, clears PDIR, and asserts nWRITE. Chip asserts nDATASTB or nADDRSTRB indicating that PData bus contains valid information, and the WRITE signal is valid. Peripheral deasserts nWAIT, indicating that any setup requirements have been satisfied and the chip may begin the termination phase of the cycle. a) The chip deasserts nDATASTB or nADDRSTRB, this marks the beginning of the termination phase. If it has not already done so, the peripheral should latch the information byte now. b) The chip latches the data from the SData bus for the PData bus and asserts (releases) IOCHRDY allowing the host to complete the write cycle. Peripheral asserts nWAIT, indicating to the host that any hold time requirements have been satisfied and acknowledging the termination of the cycle. Chip may modify nWRITE and nPDATA in preparation for the next cycle.
7.
8.
9.
SMSC DS - FDC37N958FR
Page 106
Rev. 09/01/99
EPP 1.9 Read The timing for a read operation (data) is shown in timing diagram EPP Read Data cycle. IOCHRDY is driven active low at the start of each EPP read and is released when it has been determined that the read cycle can complete. The read cycle can complete under the following circumstances: 1. If the EPP bus is not ready (nWAIT is active low) when nDATASTB goes active then the read can complete when nWAIT goes inactive high. If the EPP bus is ready (nWAIT is inactive high) then the chip must wait for it to go active low before changing the state of WRITE or before nDATASTB goes active. The read can complete once nWAIT is determined inactive.
The chip latches the data from the PData bus for the SData bus and deasserts nDATASTB or nADDRSTRB. This marks the beginning of the termination phase. b) The chip drives the valid data onto the SData bus and asserts (releases) IOCHRDY allowing the host to complete the read cycle. 9. Peripheral tri-states the PData bus and asserts nWAIT, indicating to the host that the PData bus is tri-stated. 10. Chip may modify nWRITE, PDIR and nPDATA in preparation for the next cycle. EPP 1.7 OPERATION When the EPP 1.7 mode is selected in the configuration register, the standard and bidirectional modes are also available. If no EPP Read, Write or Address cycle is currently executing, then the PDx bus is in the standard or bi-directional mode, and all output signals (STROBE, AUTOFD, INIT) are as set by the SPP Control Port and direction is controlled by PCD of the Control port. In EPP mode, the system timing is closely coupled to the EPP timing. For this reason, a watchdog timer is required to prevent system lockup. The timer indicates if more than 10usec have elapsed from the start of the EPP cycle (nIOR or nIOW asserted) to the end of the cycle nIOR or nIOW deasserted). If a time-out occurs, the current EPP cycle is aborted and the time-out condition is indicated in Status bit 0.
8.
a)
2.
Read Sequence of Operation 1. 2. 3. 4. 5. 6. 7. The host selects an EPP register and drives nIOR active. The chip drives IOCHRDY inactive (low). If WAIT is not asserted, the chip must wait until WAIT is asserted. The chip tri-states the PData bus and deasserts nWRITE. Chip asserts nDATASTB or nADDRSTRB indicating that PData bus is tri-stated, PDIR is set and the nWRITE signal is valid. Peripheral drives PData bus valid. Peripheral deasserts nWAIT, indicating that PData is valid and the chip may begin the termination phase of the cycle.
SMSC DS - FDC37N958FR
Page 107
Rev. 09/01/99
Software Constraints Before an EPP cycle is executed, the software must ensure that the control register bits D0, D1 and D3 are set to zero. Also, bit D5 (PCD) is a logic "0" for an EPP write or a logic "1" for and EPP read. EPP 1.7 Write The timing for a write operation (address or data) is shown in timing diagram EPP 1.7 Write Data or Address cycle. IOCHRDY is driven active low when nWAIT is active low during the EPP cycle. This can be used to extend the cycle time. The write cycle can complete when nWAIT is inactive high. Write Sequence of Operation 2. 1. 2. 3. 4. 5. 6. The host sets PDIR bit in the control register to a logic "0". This asserts nWRITE. The host selects an EPP register, places data on the SData bus and drives nIOW active. The chip places address or data on PData bus. Chip asserts nDATASTB or nADDRSTRB indicating that PData bus contains valid information, and the WRITE signal is valid. If nWAIT is asserted, IOCHRDY is deasserted until the peripheral deasserts nWAIT or a time-out occurs. When the host deasserts nIOW the chip deasserts nDATASTB or nADDRSTRB and 3. 4. 5. 6. 7. 8. 9. 7.
latches the data from the SData bus for the PData bus. Chip may modify nWRITE, PDIR and nPDATA in preparation of the next cycle.
EPP 1.7 Read The timing for a read operation (data) is shown in timing diagram EPP 1.7 Read Data cycle. IOCHRDY is driven active low when nWAIT is active low during the EPP cycle. This can be used to extend the cycle time. The read cycle can complete when nWAIT is inactive high. Read Sequence of Operation 1. The host sets PDIR bit in the control register to a logic "1". This deasserts nWRITE and tri-states the PData bus. The host selects an EPP register and drives nIOR active. Chip asserts nDATASTB or nADDRSTRB indicating that PData bus is tri-stated, PDIR is set and the nWRITE signal is valid. If nWAIT is asserted, IOCHRDY is deasserted until the peripheral deasserts nWAIT or a time-out occurs. The Peripheral drives PData bus valid. The Peripheral deasserts nWAIT, indicating that PData is valid and the chip may begin the termination phase of the cycle. When the host deasserts nIOR the chip deasserts nDATASTB or nADDRSTRB. Peripheral tri-states the PData bus. Chip may modify nWRITE, PDIR and nPDATA reparation of the next cycle.
SMSC DS - FDC37N958FR
Page 108
Rev. 09/01/99
Table 45 - EPP Pin Descriptions EPP SIGNAL nWRITE PD<0:7> INTR WAIT EPP NAME nWrite Address/Data Interrupt nWait TYPE O I/O I I EPP DESCRIPTION This signal is active low. It denotes a write operation. Bi-directional EPP byte wide address and data bus. This signal is active high and positive edge triggered. (Pass through with no inversion, Same as SPP.) This signal is active low. It is driven inactive as a positive acknowledgement from the device that the transfer of data is completed. It is driven active as an indication that the device is ready for the next transfer. This signal is active low. It is used to denote data read or write operation. This signal is active low. When driven active, the EPP device is reset to its initial operational mode. This signal is active low. write operation. Same as SPP mode. Same as SPP mode. Same as SPP mode. This output shows the direction of the data transfer on the parallel port bus. A low means an output/write condition and a high means an input/read condition. This signal is normally a low (output/write) unless PCD of the control register is set or if an EPP read cycle is in progress. It is used to denote address read or
DATASTB RESET ADDRSTB PE SLCT nERR PDIR
nData Strobe nReset nAddress Strobe Paper End Printer Selected Status Error Parallel Port Direction
O O O I I I O
Note 1: SPP and EPP can use 1 common register. Note 2: nWrite is the only EPP output that can be over-ridden by SPP control port during an EPP cycle. For correct EPP read cycles, PCD is required to be a low.
SMSC DS - FDC37N958FR
Page 109
Rev. 09/01/99
EXTENDED CAPABILITIES PARALLEL PORT Vocabulary ECP provides a number of advantages, some of which are listed below. The individual features are explained in greater detail in the remainder of this section. ! High performance half-duplex forward and reverse channel ! Interlocked handshake, for fast reliable transfer ! Optional single byte RLE compression for improved throughput (64:1) ! Channel addressing for low-cost peripherals ! Maintains link and data layer separation ! Permits the use of active output drivers ! Permits the use of adaptive signal timing ! Peer-to-peer capability The following terms are used in this document: When a signal asserts it transitions to a "true" state, when a signal deasserts it transitions to a "false" state. forward: Host to Peripheral communication. reverse: Peripheral to Host communication. PWord: A port word; equal in size to the width of the ISA interface. For this implementation, PWord is always 8 bits. 1: A high level. 0: A low level. assert:
SMSC DS - FDC37N958FR
Page 110
Rev. 09/01/99
These terms may be considered synonymous: ! ! ! ! ! ! ! ! PeriphClk, nAck HostAck, nAutoFd PeriphAck, Busy nPeriphRequest, nFault nReverseRequest, nInit nAckReverse, PError Xflag, Select ECPMode, nSelectln D7 data ecpAFifo dsr dcr cFifo ecpDFifo tFifo cnfgA cnfgB ecr 0 0 MODE 0 0 compress intrValue PD7 Addr/RLE nBusy 0 nAck 0 PError Direction D6 PD6 D5 PD5 D4 PD4 Select ackIntEn
!
HostClk, nStrobe
Reference Document IEEE 1284 Extended Capabilities Port Protocol and ISA Interface Standard, Rev 1.14, July 14, 1993. This document is available from Microsoft. The bit map of the Extended Parallel Port registers is: D3 PD3 nFault SelectIn D2 PD2 0 nInit D1 PD1 0 autofd D0 PD0 2 0 strobe 1 1 2 2 2 0 0 dmaEn 0 0
serviceIntr
NOTE
Address or RLE field
Parallel Port Data FIFO ECP Data FIFO Test FIFO 1 0
nErrIntrEn
0 0 full
0 0 empty
Note 1: These registers are available in all modes. Note 2: All FIFOs use one common 16 byte FIFO.
SMSC DS - FDC37N958FR
Page 111
Rev. 09/01/99
ISA IMPLEMENTATION STANDARD This specification describes the standard ISA interface to the Extended Capabilities Port (ECP). All ISA devices supporting ECP must meet the requirements contained in this section or the port will not be supported by Microsoft. For a description of the ECP Protocol, please refer to the IEEE 1284 Extended Capabilities Port Protocol and ISA Interface Standard, Rev. 1.14, July 14, 1993. This document is available from Microsoft. Description The port is software and hardware compatible with existing parallel ports so that it may be used as a standard LPT port if ECP is not required. The port is designed to be simple and requires a small number of gates to implement. It does not do any "protocol" negotiation, rather it provides an
automatic high burst-bandwidth channel that supports DMA for ECP in both the forward and reverse directions. Small FIFOs are employed in both forward and reverse directions to smooth data flow and improve the maximum bandwidth requirement. The size of the FIFO is 16 bytes deep. The port supports an automatic handshake for the standard parallel port to improve compatibility mode transfer speed. The port also supports run length encoded (RLE) decompression (required) in hardware. Compression is accomplished by counting identical bytes and transmitting an RLE byte that indicates how many times the next byte is to be repeated. Decompression simply intercepts the RLE byte and repeats the following byte the specified number of times. Hardware support for compression is optional.
SMSC DS - FDC37N958FR
Page 112
Rev. 09/01/99
NAME nStrobe PData 7:0 nAck PeriphAck (Busy)
TYPE O I/O I I
Table 46 - ECP Pin Descriptions DESCRIPTION During write operations nStrobe registers data or address into the slave on the asserting edge (handshakes with Busy). Contains address or data or RLE data. Indicates valid data driven by the peripheral when asserted. This signal handshakes with nAutoFd in reverse. This signal deasserts to indicate that the peripheral can accept data. This signal handshakes with nStrobe in the forward direction. In the reverse direction this signal indicates whether the data lines contain ECP command information or data. The peripheral uses this signal to flow control in the forward direction. It is an "interlocked" handshake with nStrobe. PeriphAck also provides command information in the reverse direction. Used to acknowledge a change in the direction the transfer (asserted = forward). The peripheral drives this signal low to acknowledge nReverseRequest. It is an "interlocked" handshake with nReverseRequest. The host relies upon nAckReverse to determine when it is permitted to drive the data bus. Indicates printer on line. Requests a byte of data from the peripheral when asserted, handshaking with nAck in the reverse direction. In the forward direction this signal indicates whether the data lines contain ECP address or data. The host drives this signal to flow control in the reverse direction. It is an "interlocked" handshake with nAck. HostAck also provides command information in the forward phase. Generates an error interrupt when asserted. This signal provides a mechanism for peer-to-peer communication. This signal is valid only in the forward direction. During ECP Mode the peripheral is permitted (but not required) to drive this pin low to request a reverse transfer. The request is merely a "hint" to the host; the host has ultimate control over the transfer direction. This signal would be typically used to generate an interrupt to the host CPU. Sets the transfer direction (asserted = reverse, deasserted = forward). This pin is driven low to place the channel in the reverse direction. The peripheral is only allowed to drive the bi-directional data bus while in ECP Mode and HostAck is low and nSelectIn is high. Always deasserted in ECP mode.
PError (nAckReverse)
I
Select nAutoFd (HostAck)
I O
nFault (nPeriphRequest)
I
nInit
O
nSelectIn
O
SMSC DS - FDC37N958FR
Page 113
Rev. 09/01/99
Register Definitions The register definitions are based on the standard IBM addresses for LPT. All of the standard printer ports are supported. The additional registers attach to an upper bit decode of the standard LPT port definition to avoid conflict with standard
ISA devices. The port is equivalent to a generic parallel port interface and may be operated in that mode. The port registers vary depending on the mode field in the ecr. The table below lists these dependencies. Operation of the devices in modes other that those specified is undefined.
NAME data ecpAFifo dsr dcr cFifo ecpDFifo tFifo cnfgA cnfgB ecr
Table 47 - ECP Register Definitions ADDRESS (Note 1) ECP MODES FUNCTION +000h R/W +000h R/W +001h R/W +002h R/W +400h R/W +400h R/W +400h R/W +400h R +401h R/W +402h R/W 000-001 011 All All 010 011 110 111 111 All Data Register ECP FIFO (Address) Status Register Control Register Parallel Port Data FIFO ECP FIFO (DATA) Test FIFO Configuration Register A Configuration Register B Extended Control Register
Note 1: These addresses are added to the parallel port base address as selected by configuration register or jumpers. Note 2: All addresses are qualified with AEN. Refer to the AEN pin definition.
SMSC DS - FDC37N958FR
Page 114
Rev. 09/01/99
MODE 000 001 010 011 100 101 110 111 SPP mode
Table 48 - Mode Descriptions DESCRIPTION* PS/2 Parallel Port mde Parallel Port Data FIFO mode ECP Parallel Port mode EPP mode (If this option is enabled in the configuration registers) (Reserved) Test mode Configuration mode
*Refer to ECR Register Description DATA and ecpAFifo PORT ADDRESS OFFSET = 00H Modes 000 and 001 (Data Port) The Data Port is located at an offset of '00H' from the base address. The data register is cleared at initialization by RESET. During a WRITE operation, the Data Register latches the contents of the data bus on the rising edge of the nIOW input. The contents of this register are buffered (non inverting) and output onto the PD0 - PD7 ports. During a READ operation, PD0 - PD7 ports are read and output to the host CPU. Mode 011 (ECP FIFO - Address/RLE) A data byte written to this address is placed in the FIFO and tagged as an ECP Address/RLE. The hardware at the ECP port transmitts this byte to the peripheral automatically. The operation of this register is ony defined for the forward direction (direction is 0). Refer to the ECP Parallel Port Forward Timing Diagram, located in the Timing Diagrams section of this data sheet. DEVICE STATUS REGISTER (dsr) ADDRESS OFFSET = 01H The Status Port is located at an offset of '01H' from the base address. Bits 0-2 are not implemented as register bits, during a read of the Printer Status Register these bits are a low level. The bits of the Status Port are defined as follows: BIT 3 nFault The level on the nFault input is read by the CPU as bit 3 of the Device Status Register. BIT 4 Select The level on the Select input is read by the CPU as bit 4 of the Device Status Register. BIT 5 PError The level on the PError input is read by the CPU as bit 5 of the Device Status Register. Printer Status Register. BIT 6 nAck The level on the nAck input is read by the CPU as bit 6 of the Device Status Register. BIT 7 nBusy The complement of the level on the BUSY input is read by the CPU as bit 7 of the Device Status Register.
SMSC DS - FDC37N958FR
Page 115
Rev. 09/01/99
DEVICE CONTROL REGISTER (dcr) ADDRESS OFFSET = 02H The Control Register is located at an offset of '02H' from the base address. The Control Register is initialized to zero by the RESET input, bits 0 to 5 only being affected; bits 6 and 7 are hard wired low. BIT 0 STROBE - STROBE This bit is inverted and output onto the nSTROBE output. BIT 1 AUTOFD - AUTOFEED This bit is inverted and output onto the nAUTOFD output. A logic "1" causes the printer to generate a line feed after each line is printed. A logic "0" means no autofeed. BIT 2 nINIT - nINITIATE OUTPUT This bit is output onto the nINIT output without inversion. BIT 3 SELECTIN This bit is inverted and output onto the nSLCTIN output. A logic "1" on this bit selects the printer; a logic "0" means the printer is not selected. BIT 4 ackIntEn - INTERRUPT REQUEST ENABLE The interrupt request enable bit when set to a high level may be used to enable interrupt requests from the Parallel Port to the CPU due to a low to high transition on the nACK input. Refer to the description of the interrupt under Operation, Interrupts. BIT 5 DIRECTION If mode=000 or mode=010, this bit has no effect and the direction is always out regardless of the state of this bit. In all other modes, Direction is valid and a logic 0 means that the printer port is in output mode (write); a logic "1" means that the printer port is in input mode (read).
BITS 6 and 7 during a read are a low level, and cannot be written. cFifo (Parallel Port Data FIFO) ADDRESS OFFSET = 400h Mode = 010 Bytes written or DMAed from the system to this FIFO are transmitted by a hardware handshake to the peripheral using the standard parallel port protocol. Transfers to the FIFO are byte aligned. This mode is only defined for the forward direction. ecpDFifo (ECP Data FIFO) ADDRESS OFFSET = 400H Mode = 011 Bytes written or DMAed from the system to this FIFO, when the direction bit is "0", are transmitted by a hardware handshake to the peripheral using the ECP parallel port protocol. Transfers to the FIFO are byte aligned. Data bytes from the peripheral are read under automatic hardware handshake from ECP into this FIFO when the direction bit is "1". Reads or DMAs from the FIFO will return bytes of ECP data to the system. tFifo (Test FIFO Mode) ADDRESS OFFSET = 400H Mode = 110 Data bytes may be read, written or DMAed to or from the system to this FIFO in any direction. Data in the tFIFO will not be transmitted to the to the parallel port lines using a hardware protocol handshake. However, data in the tFIFO may be displayed on the parallel port data lines. The tFIFO will not stall when overwritten or underrun. If an attempt is made to write data to a full tFIFO, the new data is not accepted into the tFIFO. If an attempt is made to read data from an empty tFIFO, the last data byte is re-read again. The full and empty bits must always keep track of the correct FIFO state. The tFIFO will transfer
SMSC DS - FDC37N958FR
Page 116
Rev. 09/01/99
data at the maximum ISA rate so that software may generate performance metrics. The FIFO size and interrupt threshold can be determined by writing bytes to the FIFO and checking the full and serviceIntr bits. The writeIntrThreshold can be derermined by starting with a full tFIFO, setting the direction bit to "0" and emptying it a byte at a time until serviceIntr is set. This may generate a spurious interrupt, but will indicate that the threshold has been reached. The readIntrThreshold can be derermined by setting the direction bit to "1" and filling the empty tFIFO a byte at a time until serviceIntr is set. This may generate a spurious interrupt, but will indicate that the threshold has been reached. Data bytes are always read from the head of tFIFO regardless of the value of the direction bit. For example if 44h, 33h, 22h is written to the FIFO, then reading the tFIFO will return 44h, 33h, 22h in the same order as was written. cnfgA (Configuration Register A) ADDRESS OFFSET = 400H Mode = 111 This register is a read only register. When read, 10H is returned. This indicates to the system that this is an 8-bit implementation. (PWord = 1 byte) cnfgB (Configuration Register B) ADDRESS OFFSET = 401H Mode = 111 BIT 7 compress This bit is read only. During a read it is a low level. This means that this chip does not support hardware RLE compression. It does support hardware de-compression! BIT 6 intrValue Returns the value on the ISA iRq line to determine possible conflicts.
BITS 5:0 Reserved During a read are a low level. These bits cannot be written. ecr (Extended Control Register) ADDRESS OFFSET = 402H Mode = all This register controls the extended ECP parallel port functions. BITS 7 - 5 These bits are Read/Write and select the Mode. BIT 4 nErrIntrEn Read/Write (Valid only in ECP Mode) 1: Disables the interrupt generated on the asserting edge of nFault. 0: Enables an interrupt pulse on the high to low edge of nFault. Note that an interrupt will be generated if nFault is asserted (interrupting) and this bit is written from a 1 to a 0. This prevents interrupts from being lost in the time between the read of the ecr and the write of the ecr. BIT 3 dmaEn Read/Write 1: Enables DMA (DMA starts when serviceIntr is 0). 0: Disables DMA unconditionally. BIT 2 serviceIntr Read/Write 1: Disables DMA and all of the service interrupts. 0: Enables one of the following 3 cases of interrupts. Once one of the 3 service interrupts has occurred serviceIntr bit shall be set to a 1 by hardware. It must be reset to 0 to re-enable the interrupts. Writing this bit to a 1 will not cause an interrupt. case dmaEn=1: During DMA (this bit is set to a "1" when terminal count is reached). case dmaEn=0 direction=0:
SMSC DS - FDC37N958FR
Page 117
Rev. 09/01/99
This bit shall be set to 1 whenever there are writeIntrThreshold or more bytes free in the FIFO. case dmaEn=0 direction=1: This bit shall be set to 1 whenever there are readIntrThreshold or more valid bytes to be read from the FIFO.
BIT 1 full Read only 1: The FIFO cannot accept another byte or the FIFO is completely full. 0: The FIFO has at least 1 free byte. BIT 0 empty Read only 1: The FIFO is completely empty. 0: The FIFO contains at least 1 byte of data.
R/W 000:
Table 49 - Extended Control Register MODE Standard Parallel Port Mode . In this mode the FIFO is reset and common collector drivers are used on the control lines (nStrobe, nAutoFd, nInit and nSelectIn). Setting the direction bit will not tri-state the output drivers in this mode. PS/2 Parallel Port Mode. Same as above except that direction may be used to tri-state the data lines and reading the data register returns the value on the data lines and not the value in the data register. All drivers have active pull-ups (push-pull). Parallel Port FIFO Mode. This is the same as 000 except that bytes are written or DMAed to the FIFO. FIFO data is automatically transmitted using the standard parallel port protocol. Note that this mode is only useful when direction is 0. All drivers have active pull-ups (push-pull). ECP Parallel Port Mode. In the forward direction (direction is 0) bytes placed into the ecpDFifo and bytes written to the ecpAFifo are placed in a single FIFO and transmitted automatically to the peripheral using ECP Protocol. In the reverse direction (direction is 1) bytes are moved from the ECP parallel port and packed into bytes in the ecpDFifo. All drivers have active pull-ups (push-pull). Selects EPP Mode: In this mode, EPP is selected if the EPP supported option is selected in configuration register L3-CRF0. All drivers have active pull-ups (push-pull). Reserved Test Mode. In this mode the FIFO may be written and read, but the data will not be transmitted on the parallel port. All drivers have active pull-ups (push-pull). Configuration Mode. In this mode the confgA, confgB registers are accessible at 0x400 and 0x401. All drivers have active pull-ups (push-pull).
001:
010:
011:
100: 101: 110: 111:
SMSC DS - FDC37N958FR
Page 118
Rev. 09/01/99
OPERATION Mode Switching/Software Control Software will execute P1284 negotiation and all operation prior to a data transfer phase under programmed I/O control (mode 000 or 001). Hardware provides an automatic control line handshake, moving data between the FIFO and the ECP port only in the data transfer phase (modes 011 or 010). Setting the mode to 011 or 010 will cause the hardware to initiate data transfer. If the port is in mode 000 or 001 it may switch to any other mode. If the port is not in mode 000 or 001 it can only be switched into mode 000 or 001. The direction can only be changed in mode 001. Once in an extended forward mode the software should wait for the FIFO to be empty before switching back to mode 000 or 001. In this case all control signals will be deasserted before the mode switch. In an ecp reverse mode the software waits for all the data to be read from the FIFO before changing back to mode 000 or 001. Since the automatic hardware ecp reverse handshake only cares about the state of the FIFO it may have acquired extra data which will be discarded. It may in fact be in the middle of a transfer when the mode is changed back to 000 or 001. In this case the port will deassert nAutoFd independent of the state of the transfer. The design shall not cause glitches on the handshake signals if the software meets the constraints above. ECP Operation Prior to ECP operation the Host must negotiate on the parallel port to determine if the peripheral supports the ECP protocol. This is a somewhat complex negotiation carried out under program control in mode 000.
After negotiation, it is necessary to initialize some of the port bits. The following are required: ! Set Direction = 0, enabling the drivers. ! Set strobe = 0, causing the nStrobe signal to default to the deasserted state. ! Set autoFd = 0, causing the nAutoFd signal to default to the deasserted state. ! Set mode = 011 (ECP Mode) ECP address/RLE bytes or data bytes may be sent automatically by writing the ecpAFifo or ecpDFifo respectively. Note that all FIFO data transfers are byte wide and byte aligned. Address/RLE transfers are byte-wide and only allowed in the forward direction. The host may switch directions by first switching to mode = 001, negotiating for the forward or reverse channel, setting direction to "1" or "0", then setting mode = 011. When direction is 1 the hardware shall handshake for each ECP read data byte and attempt to fill the FIFO. Bytes may then be read from the ecpDFifo as long as it is not empty. ECP transfers may also be accomplished (albeit slowly) by handshaking individual bytes under program control in mode = 001, or 000. Termination from ECP Mode Termination from ECP Mode is similar to the termination from Nibble/Byte Modes. The host is permitted to terminate from ECP Mode only in specific well-defined states. The termination can only be executed while the bus is in the forward direction. To terminate while the channel is in the reverse direction, it must first be transitioned into the forward direction.
SMSC DS - FDC37N958FR
Page 119
Rev. 09/01/99
Command/Data ECP Mode supports two advanced features to improve the effectiveness of the protocol for some applications. The features are implemented by allowing the transfer of normal 8 bit data or 8 bit commands. When in the forward direction, normal data is transferred when HostAck is high and an 8 bit command is transferred when HostAck is low.
The most significant bit of the command indicates whether it is a run-length count (for compression) or a channel address. When in the reverse direction, normal data is transferred when PeriphAck is high and an 8 bit command is transferred when PeriphAck is low. The most significant bit of the command is always "0". Reverse channel addresses are seldom used and may not be supported in hardware
Table 50 - Forward Channel Commands (HostAck Low) & Reverse Channel Commands (PeripAck Low) D7 D[6:0] 0 1 Run-Length Count (0-127) (mode 0011 0X00 only) Channel Address (0-127)
SMSC DS - FDC37N958FR
Page 120
Rev. 09/01/99
Data Compression The ECP port supports run length encoded (RLE) decompression in hardware and can transfer compressed data to a peripheral. Run length encoded (RLE) compression in hardware is not supported. To transfer compressed data in ECP mode, the compression count is written to the ecpAFifo and the data byte is written to the ecpDFifo. Compression is accomplished by counting identical bytes and transmitting an RLE byte that indicates how many times the next byte is to be repeated. Decompression simply intercepts the RLE byte and repeats the following byte the specified number of times. When a run-length count is received from a peripheral, the subsequent data byte is replicated the specified number of times. A run-length count of zero specifies that only one byte of data is represented by the next data byte, whereas a run-length count of 127 indicates that the next byte should be expanded to 128 bytes. To prevent data expansion, however, run-length counts of zero should be avoided. Pin Definition The drivers for nStrobe, nAutoFd, nInit and nSelectIn are open-collector in mode 000 and are push-pull in all other modes. ISA Connections The interface can never stall causing the host to hang. The width of data transfers is strictly controlled on an I/O address basis per this specification. All FIFO-DMA transfers are byte wide, byte aligned and end on a byte boundary. (The PWord value can be obtained by reading Configuration Register A, cnfgA, described in the next section.) Single byte wide transfers are always possible with standard or PS/2 mode using program control of the control signals.
Interrupts The interrupts are enabled by serviceIntr in the ecr register. serviceIntr = 1 Disables the DMA and all of the service interrupts. serviceIntr = 0 Enables the selected interrupt condition. If the interrupting condition is valid, then the interrupt is generated immediately when this bit is changed from a 1 to a 0. This can occur during Programmed I/O if the number of bytes removed or added from/to the FIFO does not cross the threshold. The interrupt generated is ISA friendly in that it must pulse the interrupt line low, allowing for interrupt sharing. After a brief pulse low following the interrupt event, the interrupt line is tri-stated so that other interrupts may assert. An interrupt is generated when: 1. For DMA transfers: When serviceIntr is "0", dmaEn is 1 and the DMA TC is received. 2. For Programmed I/O: a. When serviceIntr is 0, dmaEn is 0, direction is "0" and there are writeIntrThreshold or more free bytes in the FIFO. Also, an interrupt is generated when serviceIntr is cleared to 0 whenever there are writeIntrThreshold or more free bytes in the FIFO. b. (1) When serviceIntr is "0", dmaEn is 0, direction is "1" and there are readIntrThreshold or more bytes in the FIFO. (2) An interrupt is also generated when serviceIntr is cleared to "0" whenever there are readIntrThreshold or more bytes in the FIFO.
SMSC DS - FDC37N958FR
Page 121
Rev. 09/01/99
3. When nErrIntrEn is 0 and nFault transitions from high to low or when nErrIntrEn is set from "1" to "0" and nFault is asserted. 4. When ackIntEn is "1" and the nAck signal transitions from a low to a high. FIFO Operation The FIFO threshold is set in the chip configuration registers. All data transfers to or from the parallel port can proceed in DMA or Programmed I/O (non-DMA) mode as indicated by the selected mode. The FIFO is used by selecting the Parallel Port FIFO mode or ECP Parallel Port Mode. (FIFO test mode will be addressed separately.) After a reset, the FIFO is disabled. Each data byte is transferred by a Programmed I/O cycle or PDRQ depending on the selection of DMA or Programmed I/O mode. The following paragraphs detail the operation of the FIFO flow control. In these descriptions, ranges from 1 to 16. The parameter FIFOTHR, which the user programs, is one less and ranges from 0 to 15. A low threshold value (i.e. 2) results in longer periods of time between service requests, but requires faster servicing of the request for both read and write cases. The host must be very responsive to the service request. This is the desired case for use with a "fast" system. A high value of threshold (i.e. 12) is used with a "sluggish" system by affording a long latency period after a service request, but results in more frequent service requests. DMA TRANSFERS DMA transfers are always to or from the ecpDFifo, tFifo or CFifo. DMA utilizes the standard PC DMA services. To use the DMA transfers, the host first sets up the direction and state as in the
programmed I/O case. Then it programs the DMA controller in the host with the desired count and memory address. Lastly it sets dmaEn to "1" and serviceIntr to 0. The ECP requests DMA transfers from the host by activating the PDRQ pin. The DMA will empty or fill the FIFO using the appropriate direction and mode. When the terminal count in the DMA controller is reached, an interrupt is generated and serviceIntr is asserted, disabling DMA. In order to prevent possible blocking of refresh requests dReq shall not be asserted for more than 32 DMA cycles in a row. The FIFO is enabled directly by asserting nPDACK and addresses need not be valid. PINTR is generated when a TC is received. PDRQ must not be asserted for more than 32 DMA cycles in a row. After the 32nd cycle, PDRQ must be kept unasserted until nPDACK is deasserted for a minimum of 350nsec. (Note: The only way to properly terminate DMA transfers is with a TC.) DMA may be disabled in the middle of a transfer by first disabling the host DMA controller. Then setting serviceIntr to 1, followed by setting dmaEn to "0", and waiting for the FIFO to become empty or full. Restarting the DMA is accomplished by enabling DMA in the host, setting dmaEn to "1", followed by setting serviceIntr to 0. DMA Mode - Transfers from the FIFO to the Host Note: In the reverse mode, the peripheral may not continue to fill the FIFO if it runs out of data to transfer, even if the chip continues to request more data from the peripheral. The ECP activates the PDRQ pin whenever there is data in the FIFO. The DMA controller must respond to the request by reading data from the FIFO. The ECP will deactivate the PDRQ pin when the FIFO becomes empty or when the TC becomes true (qualified by nPDACK), indicating
SMSC DS - FDC37N958FR
Page 122
Rev. 09/01/99
that no more data is required. PDRQ goes inactive after nPDACK goes active for the last byte of a data transfer (or on the active edge of nIOR, on the last byte, if no edge is present on nPDACK). If PDRQ goes inactive due to the FIFO going empty, then PDRQ is active again as soon as there is one byte in the FIFO. If PDRQ goes inactive due to the TC, then PDRQ is active again when there is one byte in the FIFO, and serviceIntr has been re-enabled. (Note: A data underrun may occur if PDRQ is not removed in time to prevent an unwanted cycle.) Programmed I/O Mode or Non-DMA Mode The ECP or parallel port FIFOs may also be operated using interrupt driven programmed I/O. Software can determine the writeIntrThreshold, readIntrThreshold, and FIFO depth by accessing the FIFO in Test Mode. Programmed I/O transfers are to the ecpDFifo at 400H and ecpAFifo at 000H or from the ecpDFifo located at 400H, or to/from the tFifo at 400H. To use the programmed I/O transfers, the host first sets up the direction and state, sets dmaEn to 0 and serviceIntr to 0. The ECP requests programmed I/O transfers from the host by activating the PINTR pin. The programmed I/O will empty or fill the FIFO using the appropriate direction and mode. Note: A threshold of 16 is equivalent to a threshold of 15. These two cases are treated the same. Programmed I/O - Transfers from the FIFO to the Host In the reverse direction an interrupt occurs when serviceIntr is 0 and readIntrThreshold bytes are available in the FIFO. If at this time the FIFO is full it can be emptied completely in a single burst, otherwise readIntrThreshold bytes may be read from the FIFO in a single burst.
readIntrThreshold = (16-) data bytes in FIFO An interrupt is generated when serviceIntr is 0 and the number of bytes in the FIFO is greater than or equal to (16-). (If the threshold = 12, then the interrupt is set whenever there are 4-16 bytes in the FIFO.) The PINT pin can be used for interrupt-driven systems. The host must respond to the request by reading data from the FIFO. This process is repeated until the last byte is transferred out of the FIFO. If at this time the FIFO is full, it can be completely emptied in a single burst, otherwise a minimum of (16) bytes may be read from the FIFO in a single burst. Programmed I/O - Transfers from the Host to the FIFO In the forward direction an interrupt occurs when serviceIntr is 0 and there are writeIntrThreshold or more bytes free in the FIFO. At this time if the FIFO is empty it can be filled with a single burst before the empty bit needs to be re-read. Otherwise it may be filled with writeIntrThreshold bytes. writeIntrThreshold = (16-) free bytes in FIFO An interrupt is generated when serviceIntr is 0 and the number of bytes in the FIFO is less than or equal to . (If the threshold = 12, then the interrupt is set whenever there are 12 or less bytes of data in the FIFO.) The PINT pin can be used for interrupt-driven systems. The host must respond to the request by writing data to the FIFO. If at this time the FIFO is empty, it can be completely filled in a single burst, otherwise a minimum of (16-) bytes may be written to the FIFO in a single burst. This process is repeated until the last byte is transferred into the FIFO.
SMSC DS - FDC37N958FR
Page 123
Rev. 09/01/99
PARALLEL PORT INTERFACE MULTIPLEXOR The Parallel Port Physical Interface (PPPI) may be owned and controlled by any of three sources. The sources are detailed as follows:
Table 51 - Parallel Port Multiplexing Options PPPI CONTROLLING SOURCE DEVICE 8051 CONFIG REGISTER 0X25 BITS[4:3] [X:X]
FDC
Host
DESCRIPTION The parallel port physical interface is configured as a SPP mode bi-directional parallel port controlled directly by the 8051 through a set of memory mapped external RAM registers. The parallel port physical interface is configured as a standard Floppy Disk Drive interface. All configuration and control bits pertaining to the FDC logical device apply to the PPPI in this mode The parallel port physical interface is configured as the legacy parallel port which supports Compatible, SPP, EPP and ECP modes of operation. All configuration and control bits pertaining to the parallel port logical device apply to the PPPI in this mode.
PP_HA 0
[1:0] or [0:1]
1
[0:0] or [1:1]
1
When the Host (Parallel Port logical device) owns/controls the parallel port interface, its state (i.e., pwrdown) determines the states of the pins. When the FDC (FDC logical device) owns/controls the Parallel Port interface, its state (i.e., powerdown) determines the state of the pins. When the 8051 controls/owns the parallel port interface, it has direct control of the Parallel Port Physical Interface pins. Under 8051 control the Parallel Port Output pins are always enabled or driven and only tri-state when VCC2 is removed (powergood=0).
If the Host does not have control of the Parallel Port Physical Interface (PPPI), then it is left as a function of the software driver or BIOS to deactivate the DRQ and IRQ of the Parallel Port Logical Device by either setting its DMA Channel Select Configuration Register to 0x04 and its Interrupt Select Configuration Regsiter to 0x00 or by clearing the Parallel Port Logical Device's Activate bit. Also, if the Host does not have control of the PPPI, then the following parallel port logical device registers are read as follows.
SMSC DS - FDC37N958FR
Page 124
Rev. 09/01/99
Data Register (read) = last Data Register (write). Control Register (read): read as "cable not connected" [STROBE, AUTOFD, and SLC = 0 and nINIT = 1. Status Register (read): nBUSY, PE, SLCT = 0, nACK, nERR = 1. Note: Bit D7 of the 8051 memory mapped DISABLE register (parallel port enable bit) has no effect on the parallel port physical interface pins when the port is owned by any source other than the the Host (parallel port logical device). Host (Legacy) Parallel (FDC37N958FR Standard) Port Interface
In this mode, the parallel port pins are controlled by the host through the parallel port logical device. Refer to the Configuration section and the Parallel Port section for information on the configuration and control registers respectively. Parallel Port FDC Interface In this mode, the floppy disk control signals are available on the parallel port pins. When this mode is selected, the parallel port is not available to the Host. Parallel Port FDC pin out The FDC signals are muxed onto the `Parallel Port pins as shown in the following table. Outputs are OD24, Open Drain which sink 24ma.
Table 52 - Parallel Port Floppy Pin Out CONNECTOR PIN # CHIP PIN # PARALLEL PORT SPP MODE Pin Signal Name Direction nSTB I/O PD0 I/O PD1 I/O PD2 I/O PD3 I/O PD4 I/O PD5 I/O PD6 I/O PD7 I/O nACK I BUSY I PE I SLCT I nALF I/O nERR I nINIT I/O nSLCTIN I/O FDC MODE Signal Pin Name Direction nDS0 (O)* nINDEX I nTRK0 I nWP I nRDATA I nDSKCHG I MID0 I nMTR0 (O)* MID1 I nDS1 (O)* nMTR1 (O)* nWDATA O nWGATE O DRVDEN0 O nHDSEL O nDIR O nSTEP O
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
------------------
* These pins are outputs in mode PPFD2; in mode PPFD1 only one pair, depending on Drive Swap bit, is active and should be connected to the FDD, the inactive pair should not be connected to the FDD.
SMSC DS - FDC37N958FR
Page 125
Rev. 09/01/99
Parallel Port FDC Control There are two modes of operation, PPFD1 and PPFD2. These modes can be selected in Global Configuration Register 0x25 (Device Mode), bits 3 and 4. PPFD1 mode has only drive 1 on the PPFD1:
parallel port pins; PPFD2 mode has drive 0 and 1 on the parallel port pins. Note: The Drive Swap bit, FDD Mode Configuration Register bit-4 (LD0_CRF0), can be used to swap the motor and drive select outputs on of the Parallel Port FDC. Drive Swap bit = 0 Drive Swap bit = 1
PPFD2:
Drive 0 is on the FDC pins. Drive 1 is on the parallel port pins. Drive 1 is on the FDC pins. Drive 0 is on the parallel port pins. Drive 0 is on the parallel port pins. Drive 1 is on the parallel port pins.
The following FDC output pins are Open Drain 24mA outputs when the Parallel Port FDC is selected by the drive select register. Reminder, it is up to the designer to provide pull-up resistors on these FDC output pins. nWDATA, DRVDEN0, nHDSELm nWGATE, nDIR, nSTEP, nDS1, nDS0, nMTR0, nMTR1. Parallel Port - 8051 Control (FDC37N958FR Standard) In this mode, the parallel port pins are controlled by the 8051 through a set of three on-chip memory mapped registers. The memory mapped registers are the PAR PORT STATUS, the PAR PORT CONTROL, and the PAR PORT DATA registers. In this mode, the parallel port pins are not controlled by the parallel port logical device. Refer to the 8051 section of this specification for information on these control registers.
Table 53 - FDC on Parallel Port Activation Control
PARALLEL PORT IN POWER DOWN x x x x N Y x
FDC PARALLEL PORT MODE CR25 BITS [4:3] 01 or 10 01 or 10 01 or 10 00 or 11 00 or 11 00 or 11 00 or 11
FDC ACTIVE BIT L0-CR30-BIT0 0 1 1 x x x x
FDC IN POWER DOWN x N Y x x x x
PARALLEL PORT ACTIVE BIT x x x 0 1 1 x
PP_ HA 1 1 1 1 1 1 0
PARALLEL PORT PINS (MODE) STATE (FDC) Inactive (FDC) Active (FDC) Inactive (Parallel Port) Inactive (Parallel Port) Active (Parallel Port) Inactive (8051 Mode) Active
Inactive = Hi-z on pins Active = OD24/O24 as per selected mode. The FDD pins that are multiplexed onto the Parallel Port function independently of the state of the Parallel Port logical device. This affects the pins when CR25 bits [4:3] are 01 or 10. (Note: FDC Mode Bits L0-CRF0-B[7:6] have no effect on the parallel port Pins).
SMSC DS - FDC37N958FR
Page 126
Rev. 09/01/99
8051 EMBEDDED CONTROLLER
FEATURES " " " " " " " " " " 32K External ROM 256 Byte Internal Scratch ROM 256 Bytes Internal RAM 256 Bytes of External RAM 256 Byte External Memory/Mapped Control Register Area 128 Byte Special Function Register Area Access to 256 Byte RTC CMOS RAM 8042 style Keyboard Controller Host Interface Six Interrupt Sources Watch Dog Timer (WDT) the 8 Bit Embedded Controller Handbook. A large set of External Memory/Mapped Control Registers provide the 80C51 core with the ability to directly control many functional blocks of the FDC37N958FR. FUNCTIONAL BLOCKS Below are the functional blocks that the 8051 core has control of through its on-chip memory/mapped external registers. ! ! ! ! ! ! ! ! ! ! ! 8042 Sytle Keyboard Controller Interface Extended Interrupts Power Management Functions Direct Keyboard Scan Matrix (up to 128 keys) Four channel PS/2 Interface Access Bus Interface LED controls Two Pulse Width Modulators RTC CMOS RAM Access 8051 Control of the Parallel Port Interface 42 General Purpose I/O (GPIO) pins
8051 Functional Overview The 8051 embedded controller is a fully static CMOS core compatible with the industrystandard 80C51 microcontroller. This section concentrates on the FDC37N958FR enhancements to the 80C51. For general information about the 80C51, refer to the Hardware Description of the 8051, 8052, and 80C51 and the 80C51BH-1/80C51BH-2 CHMOS Single-Chip 8 Bit Microcomputer data sheets in
SMSC DS - FDC37N958FR
Page 127
Rev. 09/01/99
Powering up or Reseting the 8051 Default Reset Conditions The FDC37N958FR has two sources of reset: a VCC1 Power On Reset (VCC1 POR) or a VCC2 POR. An FDC37N958FR reset from any of these sources will cause the hardware response shown in Table 55, 8051 On-Chip External Memory Mapped Registers. Note that the values shown are those prior to any resident firmware control. Refer to Table 55 for the effect of each type of reset on each of the on-chip registers. Power-Up Sequence When the 8051 first powers up by VCC1, the ring oscillator is started, once this has
stabilized, the 8051 starts executing from program address 00. Once running, the 8051 can access all of the registers that are on VCC1 and if VCC2 is at 5V it can access all of the registers on VCC2. See Table 55 for VCC1 powered on-chip registers that are reset upon VCC2 Power On Reset (VCC2 POR). It is important that 8051 firmware not initialize or write to any of these registers until 1ms following VCC2 = 5V AND PWRGD = 1. Note: In order to guarantee that the external Flash device has powered up and is ready to operate before the 8051 attempts to access it, the internal VCC1 POR pulse has been extended to 20ms. The internal VCC1 POR signal is asserted upon VCC1 reaching a valid level and will remain asserted for a period of 20ms following the assertion of the VCC1_PWRGD pin.
SMSC DS - FDC37N958FR
Page 128
Rev. 09/01/99
No power to system (VCC0, VC C1, VCC2 off)
VCC0, VCC1 on; VCC2 off
VCC1 powered registers are reset to their VCC1 PO R values. IRESET_O UT bit forced high and latched by the FDC37C957FR hardware
Ring oscillator is started
O nce the ring oscillator has stabilized, the 8051 is held in reset for the required num ber of clock cycles and then released.
N nEA = 0 ? The 8051 begins executing from program address 00h.
Y The 8051 begins executing code at address 8000h.
FIGURE 4 - SYSTEM POWER UP SEQUENCE
SMSC DS - FDC37N958FR
Page 129
Rev. 09/01/99
System Reset Sequence

'*;233$&45$ $ # $%&78(+/ "B# "? 6=3=(A*+/)" C%;B4!!0 ?" )
"!#
233$&45$ '*;#?#"
?
!@!##
!##
233$&45$!
! " !#
$%&'$()*+,-. #" 233$&45$ '
233$&45$- 233$&45$! 233$&45$/#9 $%&78/
#! 6:#" ; ":#"2<= 6 $%&78
#
'
!-# /0
1
'
$ ;2>0
1 '
!#
"#
FIGURE 5 - TYPICAL SYSTEM RESET SEQUENCE
SMSC DS - FDC37N958FR
Page 130
Rev. 09/01/99
Clock Source External Clock Signal The X1K clock source is from a 14.318MHz TTL compatible clock. In "SLEEP" mode, the external clock signal on X1K is not loaded by the chip. Internal Clock Signal The 8051 may program itself to run off of an internal ring oscillator having a frequency range between 4 and 12MHz. This is not a precise clock, but is meant to provide the 8051 with a clock source when VCC2 is shut down in the system. 8051 Memory Map The 8051 can address 256B of internal Scratch ROM and 32K of external ROM. The nEA pin is used to enable access to the 256B of internal Scratch ROM or External program ROM. The FDC37N958FR also contains 256 bytes of internal on-chip RAM. When nEA=0, all the ROM is addressed as the external ROM. It can support up to 32K bytes of external code memory addressed as 00h to 7FFFh (the addresses from 8000h to FFFFh wrap to the same addresses as 00h to 7FFFh). This 32K can be mapped to any of the eight 32K memory blocks in the 256K external ROM by the KMEM register. At initial power-up (VCC1 POR)
the chip will execute from the block selected by the default value of the KMEM register. The 8051 can access upto 32K bytes of external RAM addressed from 0-7FFFh. Refer to Table 54 for a list of the implemented on-chip memory mapped registers. External memory addressed from 8000h-FFFFh will access the 32K bytes of program memory (8000-FFFFh) selected by the KMEM register. The 256 bytes of RAM from 7E00h-7EFFh as well as the 256 bytes of scratch RAM from 7D00h-7DFFh are powered by VCC1. These are general purpose read/write registers available to the 8051. The scratch RAM may be converted into scratch ROM by setting the Memory Map control bit. Memory Map Configuration Control Bit The Configuration Register 0, an 8051 memory mapped register at address 7FF4h includes a bit called the Memory Map Control bit (MMC). The MMC bit is bit-3 of this register and defaults to zero on VCC1 POR. When MMC=0 the 8051 memory map will contain an additonal 256 bytes of external scratch RAM in the address range 7D00h through 7DFFh. When MMC=1 the scratch RAM at 7D00h-7DFFh becomes scratch ROM at 00h-0FFh. The Configuration Register 0 register is described in the 8051 Control Register Section.
SMSC DS - FDC37N958FR
Page 131
Rev. 09/01/99
Memory Map with [nEA=0] If nEA is held low the 8051 memory map is shown in figure 6 below.
FFFFh
Same as 0000h - 7FFFh External
8000h 7FFFh 7F00h 7E00h 7D00h
M/M Registers RAM Scratch RAM Indirect Only
FFh 80h 00h FFh 80h
SFR (Direct Only) Direct and Indirect
Internal
Program Memory
External
Data Memory
nEA = 0, MMC bit = X
FIGURE 6 - MEMORY MAP WITH nEA = 0, MMC = X Instructions to access memory: MOV: MOVC: MOVX: Internal RAM/Registers. Program ROM from 0000h through FFFFh External RAM from 7D00h through 7FFFh -ANDExternal ROM from 8000h through FFFFh. (allows flashing of ROM).
SMSC DS - FDC37N958FR
Page 132
Rev. 09/01/99
Memory Map with [nEA=1] This section describes the 8051 memory map when the nEA pin is high. The MMC bit determines the configuration of the 8051's memory map. When nEA=1 an additional 256 of 1. Interrupt Service Routines must be absolutely located or JMP instructions must be located at {0x03, 0x0B, 0x13, 0x1B, 0x23, 0x2B} to {0x8003, 0x800B, 0x8013, 0x801B, 0x8023, 0x802B} respectively.
re-writeable ROM space can be added to the 8051's internal ROM space to allow patch code upgrades. In order to take advantage of this extra 256 bytes of scratch RAM/ROM certain design considerations must be met as outlined below. This leaves (256-51) = 205 bytes for patch code. Allows Interrupt Service Routines to be patched. Requires a Boot Block Flash type part.
2. 3.
SMSC DS - FDC37N958FR
Page 133
Rev. 09/01/99
MMC bit = 0 When the MMC bit is low (VCC1 POR default) a hard coded long jump LJMP to 8000h is
encoded at addresses 00h through 02h and a 256 byte scratch RAM is located at external addresses 7D00-7DFF. The encoding for the hard coded Long Jump is is shown in table 54.
Table 54 - Hard Coded LJMP to 8000h 8051 Address Encoding 00h 02h 80h 02h 00h
FFFFh
32K External
8000h 7FFFh 7F00h 7E00h 7D00h
M/M Registers RAM Scratch RAM Indirect Only
FFh 80h FFh 80h
SFR (Direct Only) Direct and Indirect
Internal
02h Hard Coded Internal 00h External
00h
Program Memory
Data Memory
nEA = 1, Reg MMC bit = 0
FIGURE 7 - MEMORY MAP WITH nEA =1, MMC = 0 Instructions to access memory: MOV: MOVC: MOVX: Internal RAM/Registers. Program ROM from 8000h through FFFFh External RAM from 7D00h through 7FFFh -ANDExternal ROM from 8000h through FFFh. (allows flashing of ROM).
SMSC DS - FDC37N958FR
Page 134
Rev. 09/01/99
MMC bit = 1 When the MMC bit is high the scratch RAM at 7D00h-7DFFh is disabled and now becomes the
FFFFh
executable internal scratch ROM at address locations 00h-0FFh. The hard coded LJMP to 8000h is overridden by the scratch ROM.
32K External
8000h 7FFFh 7F00h 7E00h 7D00h
M/M Registers RAM
FFh 80h
Indirect Only
FFh FFh 00h
Scratch ROM Internal
External
80h 00h
SFR (Direct Only) Direct and Indirect
Internal
Program Memory nEA = 1, MMC bit = 1
Data Memory
FIGURE 8 - MEMORY MAP WITH nEA =1, MMC =1 Instructions to access memory: MOV: MOVC: MOVX: Internal RAM/Registers. Program ROM from 8000h through FFFFh called from 00h-0FFh or from 8000h-0FFFFh. Program ROM from 00h through 0FFh called from 00h-0FFh only. External RAM from 7E00h through 7FFFh -ANDExternal ROM from 8000h through FFFFh. (allows flashing of ROM).
SMSC DS - FDC37N958FR
Page 135
Rev. 09/01/99
8051 Control Registers
Internal Special Function Registers (SFRs)
Table 55 is a map of the on-chip Special Function Register (SFR) space. The FDC37N958FR provides all standard 80C51 SFRs (see the Hardware Description of the 8051 and 8052 and 80C51 in the 8 Bit Embedded Controller Handbook).
Table 55 - SFR Memory MAP
STARTING ADDRESS F8H F0H E8H E0H D8H D0H C8H C0H B8H B0H A8H A0H 98H 90H 88H 80H IP* P3* IE* P2* SCON* P1* TCON* P0* TMOD SP TL0 DPL TL1 DPH TH0 Res TH1 Res Res PCON SBUF PSW* ACC* B* ENDING ADDRESS MSIZ FFH F7H EFH E7H DFH D7H CFH C7H BFH B7H AFH A7H 9FH 97H 8FH 87H
First Column = Starting Address Last column = Ending Address Res = Reserved for test *=Bit-addressable register Port 0: Full SFR, can be used for external memory access (but this corrupts the values in the SFR). Can not sample any pins when reading the SFR. Port 1: Does not exist. Port 2: Full SFR, can be used to supply the high address byte for internal, external (MOVX) access to the memory mapped registers or the flash registers. Port 3: Does not exist.
SMSC DS - FDC37N958FR
Page 136
Rev. 09/01/99
External Memory Mapped Control Registers (MMCRs) Table 56 describes the complete set of on-chip memory-mapped registers accessed by the 8051. The internal memory mapped registers can be accessed by the following types of instructions. 1. 2. movx movx A,@DPTR @DPTR,A
3. 4.
mov movx mov movx
P2,#7FH A,@Rx (R0 or R1 only) P2,#7FH @Rx,A (R0 or R1 only)
ISAxxh = system ISA I/O address IDXxxh = Open Mode Index Addressable Registers, See Configuration Section. 8051 Addresses = on-chip external Memory Mapped Register locations
Table 56 - 8051 On-Chip External Memory Mapped Registers
SYS. INDEX ISA 60h ISA 64h SYS. R/W W 8051 ADDRESS (7F00+) F1h 8051 R/W R POWER SOURCE VCC1 VCC1 POR N/A VCC2 POR ZERO WAIT STATE (8) Y SEE PAGE # 170
Host I/F Data Reg [KBD Data/ Command Write Reg.] Host I/F Data Reg [KBD Data Read Reg.] Host I/F Status Reg [KBD Status Reg.] RTC Address 1 RTC Data 1 RTC Address 2 RTC Data 2 HTIMER Config Reg 0 RTCCNTRL RTCADDRL RTCDATAL RTCADDRH RTCDATAH Aux Host Data Reg [KBD Data Read Reg] GATEA20 PCOBF SETGA20L RSTGA20L
NOTES (1,7)
ISA 60h
R
F1h
W
VCC1
N/A
Y
170
ISA 64h
R
F2h
R/W
VCC1
00h
Y
(2,7)
171
ISA 70h ISA 71h ISA 74h ISA 76h -----------------------------------ISA 60h
R/W R/W R/W R/W N/A N/A N/A N/A N/A N/A N/A R
--------------------F3h F4h F5h F6h F7h F8h F9h FAh
N/A N/A N/A N/A R/W R/W R/W R/W R/W R/W R/W R/W
VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1
00h N/A 00h N/A 00h 00h 80h 00h 00 00h 00h N/A
211 211 211 211 166 144 191 193 193 193 193 173
6
Y
3
---------------------
N/A N/A N/A N/A
FBh FDh FEh FFh
R/W R/W W W
VCC1 VCC1 VCC1 VCC1
01h 00h N/A N/A
176 172 176 176
SMSC DS - FDC37N958FR
Page 137
Rev. 09/01/99
Interrupt 0 source register Interrupt 0 mask register Interrupt 1 source register Interrupt 1 mask register Keyboard Scan out Keyboard Scan in Device Rev register Device ID register System-to8051 Mailbox register 0 8051-tosystem Mailbox register 1 Mailbox register [2-F] GPIO Direction register A GPIO Ouput register A GPIO Input register A GPIO Direction register B GPIO Ouput register B GPIO Input register B GPIO Direction register C GPIO Ouput register C GPIO Input register C
SYS. INDEX ------
SYS. R/W N/A
8051 ADDRESS (7F00+) 00h
8051 R/W R
POWER SOURCE VCC1
VCC1 POR 00h
VCC2 POR
ZERO WAIT STATE (8)
NOTES
SEE PAGE # 150
-----------
N/A N/A
01h 02h
R/W R
VCC1 VCC1
00h 00h
150 151
-------------------------IDX 82h
N/A N/A N/A N/A N/A R/W
03h 04h 04h 06h 07h 08h
R/W W R R R RC
VCC1 VCC1 VCC1 VCC1 VCC1 VCC1
00h 20h N/A see note 07h 00 Y 13
151 180 180 143 143 4 183
IDX 83h
RC
09h
R/W
VCC1
00
Y
5
183
IDX 84h-91h ------
R/W N/A
0A-17h 18h
R/W R/W
VCC1 VCC1
00h 00h
Y
184 199
----------------
N/A N/A N/A
19h 1Ah 1Bh
R/W R R/W
VCC1 VCC1 VCC1
00h N/A 00h
200 200 200
----------------
N/A N/A N/A
1Ch 1Dh 1Eh
R/W R R/W
VCC1 VCC1 VCC1
00h N/A 00h 12
201 201 201
-----------
N/A N/A
1Fh 20h
R/W R
VCC1 VCC1
00h N/A
12
202 202
SMSC DS - FDC37N958FR
Page 138
Rev. 09/01/99
LED register OUT register D OUT register E IN register F PWM0 register PWM1 register KSTP_CLK KMEM WAKEUP Source 1 WAKEUP Source 2 WAKEUP mask 1 WAKEUP mask 2 Multiplexing 3 register ACCESS.BU S Control reg ACCESS.BU S Status reg ACCESS.BU S Own Address reg ACCESS.BU S Data reg ACCESS.BU S Clock WAKEUP Source 3 WAKEUP Mask 3 WDT Control/Statu s WDT Timer PP Status Reg PP Control Reg PP Data Reg Multiplexing 1 register
SYS. INDEX --------------------IDX 92h IDX 93h ---------------------------------------------------
SYS. R/W N/A N/A N/A N/A R/W R/W N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
8051 ADDRESS (7F00+) 21h 22h 23h 24h 25h 26h 27h 29h 2Ah 2Bh 2Ch 2Dh 30h 31h 31h 32h
8051 R/W R/W R/W R/W R R/W R/W R/W R/W R R R/W R/W R/W W R R/W
POWER SOURCE VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1 VCC1
VCC1 POR
VCC2 POR see note FFh 0Fh
ZERO WAIT STATE (8) see note
NOTES 13 12 12
SEE PAGE # 190 202 203 203 191 191 145 156 166 166 167 168 209 187/ 225 187/ 225 187/ 229 188/ 229 188/ 230 167 168 153
N/A 00h 00h 10h 00h 00h 00h 00h 00h 00h 00h 81h 00h
Y Y
--------------------------
N/A N/A N/A N/A N/A
33h 34h 35h 36h 37h
R/W R/W R R/W R/W
VCC1 VCC1 VCC1 VCC1 VCC1
00h 00h 00h FFh 00h
------
N/A N/A N/A N/A N/A
38h 3Ah 3Bh 3Ch 3Dh
R/W R/W R/W R/W R/W
VCC1 VCC2 VCC2 VCC2 VCC1
FFh 00h 00h 00h 00h 9
153 195 196 196 204
----------------
SMSC DS - FDC37N958FR
Page 139
Rev. 09/01/99
SYS. INDEX Output Enable register DISABLE register Multiplexing 2 register PS/2 port1 Control register PS/2 port1 status register PS/2 port1 Error Status Register PS/2 port1 Transmit Reg PS/2 port1 Receive Reg RESERVED - SMSC PS/2 port2 Control register PS/2 port2 status register PS/2 port2Error Status Register PS/2 port2 Transmit Reg PS/2 port2 Receive Reg RESERVED - SMSC 256 bytes of RAM
SYS. R/W
8051 ADDRESS (7F00+) 3Eh
8051 R/W R/W
POWER SOURCE VCC1
VCC1 POR see note 00h 00h
VCC2 POR see note
ZERO WAIT STATE (8)
NOTES 11
SEE PAGE # 147
-----------
N/A N/A N/A
3Fh 40h 41h
R/W R/W R/W
VCC1 VCC1 VCC2
146 207 00h 185/ 233 185/ 234 186/ 234 186/ 234 186/ 234 ___ 185/ 234 185/ 234 186/ 234
N/A
42h
R
VCC2
00h
N/A
43h
R
VCC2
00h
N/A N/A ----------N/A N/A
44h 45h 46h-48h 49h
W R -R/W
VCC2 VCC2 ------VCC2 ----
00h 00h ---00h
------
N/A
4Ah
R
VCC2
00h
------
N/A
4Bh
R
VCC2
00h
---------------------
N/A N/A N/A N/A
4Ch 4Dh 4Eh-4Fh 7E007EFFh
W R -R/W
VCC2 VCC2 ------VCC1 ----
00h 00h ----
186/ 234 186/ 234 ___ ___
Notes 1. Although the Input and Output Data registers are physically separate, they share address 7FF1H. 2. The FDC37N958FR CPU cannot write to some bits of the Status register. 3. Writing to the Auxiliary Output Data Register loads the Output data register and can set the AUXOBF1 output if enabled. This does not set the PCOBF output.
SMSC DS - FDC37N958FR
Page 140
Rev. 09/01/99
4. 5. 6. 7. 8. 9. 10. 11.
12. 13.
Interrupt is cleared when read by the 8051 Interrupt is cleared when read by the host See RTC control Register Definition When accessed for a read or write by the system the registers marked with a "Y" will drive the zero wait state pin active. Bit 0 is the only writable or resetable bit in this register. When IRESET_OUT is cleared (written from "1" to"0") 8051STP_CLK bit D0 as well as HMEM bits D1 and D0 are all set to "1". VCC1 POR = 00000X10b, VCC2 POR = 00000X1Xb where X is not affected by VCC2 POR, but is left at the current value. These registers are reset 500us to 1ms following the condition that BOTH VCC2 is valid and PWRGD is asserted given that the RTC is in normal mode and the VRT bit is set (refer to the RTC section). If the RTC is not in normal mode and/or the VRT bit is not set then these registers are reset within 10"s following the condition that BOTH VCC2 is valid and PWRGD is asserted. This register is powered by VCC1. The data contents remains undefined until VCC2 POR. This register is impacted by a device functional revision. See FUNCTIONAL REVISION ADDENDUM on page 308 for VCC1 and VCC2 POR impact and default values.
SMSC DS - FDC37N958FR
Page 141
Rev. 09/01/99
8051 Configuration/Control Memory Mapped Registers Device Rev Register Host 8051 Power Default
By reading this register, 8051 firmware can confirm the device revision that it is running on.
N/A 0x7F06 (R) VCC1 see note
D7 D6 D5 D4 D3 D2 D1 D0 8051 R R R R R R R R R Bit description 0 0 0 0 0 0 0 1 Note: This register is hardwired. This register is impacted by device functional revision. See FUNCTIONAL REVISION ADDENDUM on page 308 for devault values. Device ID Register By reading this register, 8051 firmware can determine which device it is running on.
Host 8051 Power Default D7 R 0 D6 R 0
N/A 0x7F07 (R) VCC1 0x07 D5 R 0 D4 R 0 D3 R 0 D2 R 1 D1 R 1 D0 R 1
8051 R Bit description
SMSC DS - FDC37N958FR
Page 142
Rev. 09/01/99
Configuration Register 0 Host N/A 8051 0x7FF4 Power VCC1 Default 0x00 D7 AUXH D6 0 D5 OBFEN D4 0 D3 MMC D2 PCOBFEN D1 SAEN D0 SLEEPFLAG
AUXH Aux in Hardware; When high, AUXOBF of the status register is set in hardware by a write to 7FFAh. When low, AUXOBF of the status register is a user defined bit (UD) and R/W. OBFEN When set PCOBF is gated onto KIRQ and AUXOBF1 is gated onto MIRQ. When low, KIRQ and MIRQ are driven low. Software should not change this bit when OBF of the status register is equal to 1. MMC
PCOBFEN When high, PCOBF reflects whatever value was written to the PCOBF firmware latch assigned to 7FFDH. When low, PCOBF reflects the status of writes to 7FF1H (the output data register). SAEN Software-assist enable. When set to "1" SAEN allow control of the GATEA20 signal via firmware. If SAEN is reset to `0', GATEA20 corresponds to either the last host-initiated control of GATEA20 or the firmware write to 7FFEh or 7FFFh. SLEEPFLAG
Memory Map Control Bit : When MMC=0, a 256 Byte Scratch RAM area at 7D00h is available to the 8051. When MMC=1 the Scratch RAM at 7D00h-7DFFh becomes scratch ROM at 00h-FFh.
If SLEEPFLAG="0" when PCON bit-0 is set, the 8051 enters "IDLE" mode, whereas if SLEEPFLAG="1" when PCON bit 0 is set the 8051enters "SLEEP" mode. This bit is cleared by the occurrence of any wake-up events and on VCC1 POR.
SMSC DS - FDC37N958FR
Page 143
Rev. 09/01/99
KSTP_CLK Register Host N/A 8051 0x7F27 Power VCC1 Default 0x10 D7 KBCLK1 D6 KBCLK0 D5 KBCLK/ROSC D4 ROSCEN D3 D2 D1 D0
STP_CNT[3:0]
Note: ROSC refers to the ring oscillator. STP_CNT[x] This defines the number of machine cycles from when the internal IRESET_OUT bit is cleared until the external RESET_OUT pin goes inactive low (deasserts) . ROSCEN This bit reflects the state of the ring oscillator clock at all times. The 8051 can write this bit to start or stop the ring oscillator. Other hardware events can also start or stop this clock. = 1 turn on ring oscillator = 0 turn off ring oscillator KBCLK1 0 0 1 1 KBCLK0 0 1 0 1 stop KBCLK (default) KBCLK = 12 MHz KBCLK = 14. 318 MHz KBCLK = 16 MHz This bit is reset when the 8051 goes into "SLEEP" mode and is set when the 8051 first wakes up from "SLEEP" mode. KBCLK/ROSC This bit is used to control the clock source for the 8051. 1 = 8051 clock source is KBCLK 0 = 8051 clock source is ring oscillator. This bit is reset when the 8051 just wakes up from the "SLEEP" mode
SMSC DS - FDC37N958FR
Page 144
Rev. 09/01/99
DISABLE Register Host N/A 8051 0x7F3F Power VCC1 Default 0x00 If `0', these bits override the enable bits in the Configuration registers. D7 D6 D5 D4 D3 D2 8051 R/W R/W R/W R/W R/W R/W R/W System N/A N/A N/A N/A N/A N/A R/W User System Floppy IR Port Serial Parallel Defined Flash Port 1= Port Port Interface 1= Enable 1= 1= 1= Enable 0= Enable Enable Enable 0= Disable 0= 0= 0= Disable Disable Disable Disable Note 1
D1 R/W N/A Reserved
D0 R/W N/A Reserved
Note 1: If D2=0, then the FLASH is write protected from the system. The system can still read the FLASH.
SMSC DS - FDC37N958FR
Page 145
Rev. 09/01/99
Output Enable Register N/A 0x7F3E VCC1 00000X10b on VCC1 POR 00000X1Xb on VCC2 POR Output Enable Register VCC1 POR = 0x00000X10, VCC2 POR = 00000X1Xb where X means the bit holds its setting preceding VCC2 POR. Host 8051 Power Default D7-D4 R/W Reserved 0 AR= Access Rights 8051 AR IRESET_OUT When POWERGOOD=1, IRESET_OUT is controlled by the 8051. When POWERGOOD=0, IRESET_OUT is forced high (within 100nsec) and latched. The RESET_OUT pin is not driven until VCC2 is applied. IRESET_OUT cannot be cleared by the 8051 until POWERGOOD=1. IRESET_OVRD iRESET Override - when cleared the iRESET_OUT bit functions as described above. When set, iRESET_OUT is given direct control over the internal reset and perhaps the RESET_OUT and nRESET_OUT pins without requiring the STOP_CLK counter or affecting the 8051STP_CLK bit or the HMEM register. In the override mode, setting iRESET_OUT may or may not drive RESET_OUT high and clearing iRESET_OUT may or may not drive RESET_OUT low. The RESET_OUT Override function allows the 8051 to take the rest of the FDC37N958FR chip (SIO) out of reset without giving up control (i.e., without stopping its clock and giving the flash interface to the Host). 3) D3 R/W iRESET_ OVRD D2 R Power_Good D1 R/W iRESET_OUT D0 R/W 32KHz Output
On the current FDC37N958FR, RESET_OUT is driven low by this sequence of events. 1) 2) Sets STP_CNT to a non-zero value Clears iRESET_OUT bit, causing. a) 8051STP_CLK bit 0 to get set. b) HMEM[7:0] to get set to 0x03 c) and STOP Counter to start decrementing When STP_CNT reaches 0 the RESET_OUT pin deasserts (goes low) at which point the 8051's clock stops and the Host owns the Flash Interface.
In addition to the above sequence, the FDC37N958FR provides a means for the 8051 to directly control the state of the Super I/O block's internal reset. The FDC37N958FR provides a means for the 8051 to drive low or toggle the chip's internal reset without stopping the 8051 clock or giving the Flash interface to the host.
SMSC DS - FDC37N958FR
Page 146
Rev. 09/01/99
8051 Interrupts The FDC37N958FR provides the five standard 8051 interrupts (Group 0) plus an additional T5INT interrupt which is located at the vector address for Timer 2 which is standard on the 8051 standard micro-controller. Table 57 describes the interrupts. The Group 0 interrupts use the standard 8051 interrupt enable and priority structures. Each interrupt is individually enabled or disabled by setting or clearing a bit in the interrupt Enable
(IE) register (SFR location A8H). Each interrupt is programmed to one of two priority levels by setting or clearing a bit in the interrupt Priority (IP) register (SFR location B8H). See the "Hardware Description of the 8051, 8052, and 80C51" in the 8 Bit Embedded Controller Handbook for more details. Group 0 interrupts (which have modified sources from the standard 80C51 interrupts) are configurable as either level-or-edge sensitive. Consult the 8 Bit Embedded Controller Handbook for a full description.
INTERRUPT Group 0 INT0 T0INT INT1 T1INT Serial Port T5INT
Table 57 - Interrupt Sources VECTOR DESCRIPTION ADDRESS
POLLING ORDER
ACTIVE
Interrupt INT0 Timer 0 Interrupt Interrupt INT1 Timer 1 Interrupt Serial Port Interrupt T5 Interrupt
(1)
03H 0BH 13H 1BH 23H 2BH
0 (IE0) 1 (IE1) 2 (IE2) 3 (IE3) 4 (IE4) 5 (IE5)
L/E
L/E
E
Note: L = Level-sensitive, E = Edge-sensitive Note 1: The T5 interrupt, if enabled, is generated as a result of the occurrence of any un-masked wake-up event.
SMSC DS - FDC37N958FR
Page 147
Rev. 09/01/99
Interrupt Enable Register (IE)
This register is based on the standard 8051 IE register. It has been modified to add a definition for bit D5.
D4 0 RI+TI 8051 Serial Port Interrupt Enable Bit D3 0 TF1 Timer 1 Interrupt Enable Bit D2 0 INT1 External Interrupt 1 Enable Bit D1 0 TF0 Timer 0 Interrupt Enable Bit D0 0 INT0 External Interrupt 0 Enable Bit
Default Bit Def
D7 0 EA
D6 0
Reserved
D5 0 T5INT Interrupt Enable Bit
Interrupt Priority Register (IP)
This register is based on the standard 8051 IP register. It has been modified to add a definition for bit D5.
Default Bit Def
D7-D5 0 Reserved
D5 0 T5INT interrupt priority bit
D4 0 8051 Serial Port interrupt priority bit
D3 0 Timer 1 interrupt priority bit
D2 0 External Interrupt 1 priority bit
D1 0 Timer 0 interrupt priority bit
D0 0 External interrupt 0 priority bit
Interrupt Polling Sequence When two or more interrupts with the same priority level become active during the same machine cycle, the chip's internal polling sequence determines the service order. If all six interrupts are set to the same priority level, and all interrupts become active during the same machine cycle, the 8051 services the interrupts in the order shown in Table 57.
Additional Interrupt Sources Inside the FDC37N958FR, interrupt events from various sources are able to generate either an INT0 or INT1 8051 interrupt. The 8051 firmware masks these interrupt sources by writing "1s" into the 8051 INT0 or INT1 Mask Registers and enables these interrupts by writing "0s" into these mask registers. The 8051 can determine the source of the INT0 or INT1 interrupt by reading the 8051 INT0 or INT1 Source Register.
SMSC DS - FDC37N958FR
Page 148
Rev. 09/01/99
8051 INT0 Source Register Host N/A 8051 0x7F00 (R) Power VCC1 Default 0x00 D7-D4 R Reserved D3 R 1=MSB Receive Data Changed D2 R 1= WK_EE4 transition (both edges) D1 R 1= WK_EE2 transition (both edges) D0 R 1= WK_EE3 transition (both edges)
8051 R/W Bit Description
Note: this register is cleared on a read. 8051 INT0 Mask Register Host N/A 8051 0x7F01 Power VCC1 Default 0x00 D7-D4 R/W Reserved D3 R/W 1=mask MSB D2 R/W 1 = mask WK_EE4 (Edge) D1 R/W 1 = mask WK_EE2 transition interrupt D0 R/W 1 = mask WK_EE3 transition interrupt
8051 R/W Bit Def
When enabled, INT0 is generated on either positive or negative-going edge of WK_EE4 [ERDY].
SMSC DS - FDC37N958FR
Page 149
Rev. 09/01/99
8051 INT1 Source Register Host N/A 8051 0x7F02 (R) Power VCC1 Default 0x00 D7 R
1= IBF Note 1
8051 R/W
Bit Des.
D6 R
1= keyboard scan-in line. Note 2
D5 R
1= PS/2 port2 Flag (L to H)
D4 R
1= PS/2 port1 flag (L to H)
D3 R
1= Trigger (Both Edges) Note 3
D2 R
1=Access.bus Note 4
D1 R
1= system writes to mailbox register 0 Note 5
D0 R
1= A Wakeup event is active
Bits D0, D2-D6 are cleared by a read. To re-enable these IRQ's you must reset the interrupting condition (i.e., all active interrupts must be serviced after reading this register). Note 1: The IBF interrupt bit is set when the host writes to the KBD Data/Command Write Register and cleared when the 8051 reads the data from that register. Note 2: Bit D6 is latched on a high to low transition. of any of the keyboard scan lines. Note 3: When enabled, INT1 is generated on either positive or negative-going edge of Trigger. Note 4: An ACCESS.bus IRQ is active. Note 5: This bit is set when the system writes to mailbox register 0. This bit is cleared by a read of the mailbox 0 register 8051 INT1 Mask Register Host N/A 8051 0x7F03 Power VCC1 Default 0x00 D7 R/W 1= Mask IBF D6 R/W 1 = Mask The Keyboard Matrix Scan Flag D5 R/W 1= Mask PS/2 Port2 Flag D4 R/W 1 = Mask PS/2 Port1 Flag D3 R/W 1= Mask Trigger D2 R/W 1= Mask Access Bus D1 R/W 1 = Mask System-To8051 Mailbox Register Interrupt D0 R/W 1= Mask WakeUp Events
8051 R/W Bit Def
SMSC DS - FDC37N958FR
Page 150
Rev. 09/01/99
WATCH DOG TIMER
WDT Operation When enabled, the Watch Dog Timer (WDT) circuit will generate a system reset if the user program fails to reload the watchdog timer (WDT) within a specified length of time known as the `watchdog interval'. The WDT consists of an 8-bit timer (WDT) with a 9-bit prescaler. The prescaler is fed with 32 KHz which always runs, even if the 8051 is in SLEEP state. The 8 bit WDT timer is decremented every (1/32KHz) *512 seconds or 16.0 ms. Thus, the watchdog interval is programmable between 16ms and 4.08 seconds on 16ms intervals. WDT Action If the 8 bit timer (WDT) underflows, a VCC1 POR is generated 8051 in Idle Mode - WDT will be active if enabled. When the WDT timer underflows in idle mode, the 8051 will be reset. It is up to the firmware engineer to design code that uses a timer to generate an interrupt that will exit idle mode and re-initialize the WDT timer and then put the 8051 back into idle mode. 8051 in Sleep Mode - If enabled, the WDT is active since it is running off of the 32 KHz clock. Therefore, if the WDT is enabled the 8051 should never remain in the SLEEP state for more than 4 seconds. WDT Activation Upon VCC1 POR the Watch Dog Timer powers up inactive. The Watch Dog Timer is activated
when the WDT enable bit (WDT CONTROL bit D1) is set by 8051 firmware. The WDT may be disabled under software control through a specific sequence. Software can clear the SDT enable bit by : 1) Setting the WLE-WDT Load enable bit in the WDT Control/Status Register 2) Writing 00h to the WDT Timer Register (this causes the WDT Enable and the WLE_WDT Load Enable bits to each reset to 0). Once the WDT has been activated, this sequence must be executed in order to disable watchdog operation via software control. Note: Since a VCC1 POR will reset the WDT enable bit, the WDT must be re-enabled after each occurrence. WDT Reset Mechanism The watchdog timer (WDT) must be reloaded within periods that are shorter than the programmed watchdog interval; otherwise the WDT will underflow and a VCC1 POR will be generated. It is the responsibility of the user program to continually execute sections of code which reload the 8 bit timer (WDT). The WDT is reloaded in two stages in order to prevent erroneous software from reloading the watchdog. First WDT CONTROL bit D0 (WLEWDT Load Enable) must be set. Then the WDT may be loaded. When the WDT is loaded WLE is automatically reset. WDT can not be loaded when WLE is reset. Since the WDT timer is a down counter , a reload value of 01h results in the minimum WDT interval (16ms) and a reload value of 0FFh results in the maximum WDT interval (4.08 seconds). Loading 00h into the WDT disables the WDT and clears the WDT Enable bit. Note, the 9 bit prescaler is initialized whenever the WDT timer is loaded.
SMSC DS - FDC37N958FR
Page 151
Rev. 09/01/99
WDT Memory Mapped Registers WDT: Put at Location 7F38 (Default = 0xFF, on VCC1 POR). D7 D6 D5 D4 D3 D2 D1 8051 R/W R/W System R/W N/A Bit Def WDT Timer
D0
WDT CONTROL/STATUS: Put at Location 7F37. (Default = 0x00, on VCC1 POR). D7-D2 D1 D0 8051 R/W R R/W R/W System R/W N/A N/A N/A Bit Def Reserved WDT Enable WLE-WDT Load Enable WLE Watchdog Load Enable bit must be set to enable writing to the WDT Timer register. This bit is automatically reset when the 8051 writes to the WDT register. If this bit is reset, writes to the WDT register are ignored. WDT Enable The WDT enable bit must be set by 8051 firmware to enable or start the Watch Dog Timer. A VCC1 POR or the above described software sequence will reset this bit.
SMSC DS - FDC37N958FR
Page 152
Rev. 09/01/99
Shared Flash Interface A 256KB Flash Device (i.e., 28F020) is recommended to store the program code for the 8051 (Keyboard BIOS+) and the system BIOS. The FLASH memory can be accessed from the system in blocks of 64KB or from the 8051 in blocks of 32KB. The procedure to access the FLASH memory is described in the Host Flash Access section.
Flash Interface Diagram Access to the Flash Memory is multiplexed inside of the FDC37N958FR. The host CPU only has access to the Flash when nRESET_OUT is not asserted and the 8051 STP_CLK bit-0 is set. Please refer to the timing section for details on this interface.
HOST CPU
I S A B U S
R O M n C S AD[7:0]
ALE
LATCH
ADDR[17:8]
FLASH 256K x 8
FDC37C957FR
nKBWR nKBRD nCE
FIGURE 9 - FLASH INTERFACE DIAGRAM
SMSC DS - FDC37N958FR
Page 153
Rev. 09/01/99
System Flash Access Map
64K Host Interface FFFF
256K FLASH ROM
0
8x 32K Blocks
64K 8051 ROM FFFF 8000
Same as 0-7FFF
64K 8051 External RAM FFFF Internal Registers
FIGURE 10 - 8051 MODE 2
8000 0
0
SMSC DS - FDC37N958FR
Page 154
Rev. 09/01/99
Keyboard BIOS (KMEM) KMEM Register Host N/A 8051 0x7F29 Power VCC1 Default 0x00 D7-D3 8051 R/W System R/W Bit Def R/W N/A 00 on read D2 R/W N/A A[17] D1 R/W N/A A[16] D0 R/W N/A A[15]
The 8051 uses this register to access the Flash ROM in a 32K window. The 8051 is only barred KMEM 16 0 0 1 1 0 0 1 1
from accessing the Flash when 8051STP_CLK bit D0 =1 and RESET_OUT=low or deasserted.
17 0 0 0 0 1 1 1 1
15 0 1 0 1 0 1 0 1
Flash Memory Range 000- 7FFF 8000- FFFF 10000-17FFF 18000-1FFFF 20000-27FFF 28000-2FFFF 30000-37FFF 38000-3FFFF
SMSC DS - FDC37N958FR
Page 155
Rev. 09/01/99
System BIOS (HMEM) HMEM Register IDX 0x95 N/A VCC1 VCC1 POR = 0x03 VCC2 POR = 0x03 D7-D2 R R/W 0 D1 R R/W A[17] D0 R R/W A[16]
Host 8051 Power Default
8051 R/W System R/W Bit Def
The system uses this register to select a 64K window for access from the 256K Flash ROM. The host may access the Flash when RESET_OUT pin is de-asserted and 8051STP_CLK bit D0 = 1. Host Flash Access The FDC37N958FR has a special shared Flash ROM interface. The 8051 can be stopped to allow the Host CPU to access the flash ROM after a special handshake sequence is followed. HOST INITIATED FLASH ACCESS To access the FLASH memory, the 8051 must first be placed into idle mode, and then the 8051 clock must be stopped. Host flash reads and writes occur when the nROMCS pin is asserted along with nMEMRD or nMEMWR. The register bit "8051_STPCLK" needs to be set by the host
to make the 8051 clock stop. The 8051 clock is only stopped when 8051STP_CLK=1 and when RESET_OUT pin = low. Address bits A[15:0] are supplied by SA[15:0], address bits A[17:16] are supplied by configuration register HMEM. For Flash access, these address lines and bits are qualified (selected) by 8051STP_CLK=1, and the RESET_OUT pin = low (RESET_OUT is driven by the 8051). The 8051 STP_CLK is set to "1" and HMEM is set to 03h (effectively resulting in A[17:16] initializing as "11") whenever the 8051 clears the IRESET_OUT bit from "1" to "0". This allows the system to execute from the upper 64K of the Flash memory at boot time. To access the other portions of the Flash memory, the system software must first change the values of HMEM[1:0] register to control address lines A[17:16]. The access to the Flash memory uses nFWR for a write and nFRD for a read.
SMSC DS - FDC37N958FR
Page 156
Rev. 09/01/99
System fully powered up and running. RESET_OUT=low, 8051STP_CLK=0. 8051 owns Flash interface, running keyboard code.
The host, wishing to access Flash memory, issues a userdefined command to put the 8051into idle mode.
8051goes into idle mode
The host sets 8051STP_CLK = 1 combined with RESET_OUT = low; this causes 8051 clock to stop.
Host now owns Flash interface.
When done using Flash, the host resets 8051STP_CLK bit
Note: In order to leave idle mode the 8051 must receive an interrupt; typically a software timer interupt will be used.
N
8051 Timer IRQ ? (Note)
Y
8051 wakes up from idle mode and starts executing from where it left off.
FIGURE 11 - DYNAMIC SHARING OF FLASH INTERFACE BETWEEN HOST AND 8051
SMSC DS - FDC37N958FR
Page 157
Rev. 09/01/99
8051 STP_CLK Register Host IDX 0x94 8051 N/A Power VCC1 Default 0x00 D6 D5-D1 D0 HOST_ Reserved, set to "0" 0=8051 Clock can run FLASH 1=8051 Clock stop When bit D0=1 the 8051's clock is not stopped unless the RESET_OUT pin is also deasserted at which point the host has access to the Flash Memory. Only bit D0 is R/W, bits[7:1] are Read only. 0 = 8051 not in idle mode 1= 8051 in idle mode 0 = Host does not have access to Flash, in use by 8051 1 = Host has access to Flash The FDC37N958FR is fully static and will pickup from where it left off in the event of a wake-up event. Idle Mode Entering IDLE mode: Idle mode is initiated by an instruction that sets the PCON.0 bit (SFR address 87H) in the keyboard. In idle mode, the internal clock signal to the keyboard CPU is gated off, but not to the Interrupt Timer and Serial Port functions. The CPU status is preserved in its entirety: The Stack Pointer, Program Counter, Program Status Word, Accumulator, and all other registers maintain their data. The port pins hold the logical levels they had when Idle mode was activated. D7 IDLE
Note: Note: IDLE :
HOST_FLASH:
8051 System Power Management
The 80C51 core provides support for two further power-saving modes, available when inactive: Idel mode, typically entered between keystrokes; and sleep mode, entered upon command from the host. The 8051 is wakeable from sleep mode through a set of external and internal events called Wake-Up events. The events are listed in Table 58 - System Wake-up Events. When exiting the Sleep mode, the 8051 will continue executing code from where it left off when put into sleep with no changes to the SFR and pins.
SMSC DS - FDC37N958FR
Page 158
Rev. 09/01/99
System fully powered up and running. RESET_OUT=low, 8051STP_CLK=0. 8051 owns Flash interface, running keyboard code.
The host either issues a userdefined command to put the 8051into idle mode, or the 8051 code determines that the 8051 should enter Idle mode.
SLEEPFLAG = 0
PCON.0 = 1
8051 now in Idle mode, 8051 clock running.
FIGURE 12 - ENTERING IDLE MODE
SMSC DS - FDC37N958FR
Page 159
Rev. 09/01/99
8051 in Idle mode, 8051 clock running.
N
Unmasked 8051 IRQ ? (Note) Y
Note: In order to leave idle mode the 8051 must receive an interrupt, typically a software timer interrupt will be used.
8051 leaves Idle mode, executes IRQ service routine code and executes an IRET when done.
8051 returns to executing from where it left off prior to entering Idle mode.
FIGURE 13 - EXITING IDLE MODE DUE TO IRQ Exiting Idle Mode There are two ways to terminate Idle mode. First, activation of any enabled interrupt will cause the PCON.0 bit to be cleared by hardware. The interrupt will be serviced and, following the RETI, the CPU will resume operation by executing the instruction following the one that put the CPU into Idle mode. The second way to terminate the Idle mode is with a VCC1 POR. Note that a VCC1 POR will clear the registers. The CPU will not resume program execution from where it left off.
SMSC DS - FDC37N958FR
Page 160
Rev. 09/01/99
Sleep Mode Sleep mode sequence To enter sleep mode, the 8051: 1. 2. 3. 4. 5. 6. 7. 8. turns on the ring oscillator (KSTP_CLK[4] = 1) switches the clock source (KSTP_CLK[5] = 0) turns off the clock chip (or the whole system power, VCC2) masks all interrupts except for T5INT sets SLEEPFLAG = 1 sets PCON.0 = 1 the ring oscillator will be automatically turned off the 8051 goes into Sleep mode.
Design Note In this mode, the FDC, UART1, UART2 and parallel port are powered off if VCC2 is removed, but the RTC and 8051 are in powerdown (sleep) mode; the chip must consume less than 20"A, and all wake-up pins must still be active. Exiting Sleep Mode When the 8051 is in sleep mode, all of the clocks are stopped and the 8051 is waiting for an unmasked wake-up event. When the wakeup event occurs, the ring oscillator is started, once this has stabilized, the 8051 starts executing from where it stopped in the sleep Mode Sequence. Once running, the 8051 can access all of the registers that are on VCC1 and if VCC2 is at 5V it can access all of the registers on VCC2. The 8051 running from the ring oscillator clock source can turn on the clock chip, switch its clock source to 16 MHz and then turn off the ring oscillator clock source.
Sleep mode is initiated by a user defined command of event to the 8051. When the CPU enters sleep mode, all internal clocks, including the core clocks, are turned off. If an external crystal is used, the internal oscillator is turned off. RAM contents are preserved.
SMSC DS - FDC37N958FR
Page 161
Rev. 09/01/99
System fully powered up and running. RESET_OUT= low, 8051STP_CLK= 0. 8051 owns Flash interface, running keyboard code.
The host either issues a userdefined command to put the 8051into sleep mode, or the 8051 code determines that the 8051 should enter sleep mode.
8051 switches its clock source to the ring oscillator.
8051 masks all interrupts except for T5INT.
The 8051 may/may not turn off VCC2 to rest of system.
SLEEPFLAG = 1
PCON.0 = 1
Ring oscillator first gated off from 8051, then turned off.
8051 now in sleep mode, 8051 clock stopped.
FIGURE 14 - ENTERING SLEEP MODE
SMSC DS - FDC37N958FR
Page 162
Rev. 09/01/99
8051 in sleep mode. RTC, 8051 and other VCC1 driven pins are active
N
Unmasked Wake-up Event ? Y T5INT generated. Turn on ring oscillator. SLEEPFLAG = 0.
Wake Up Events RTC Alarm, Power Button, Ring Indicator, etc.
Once stabilized, the ring oscillator is gated through to the 8051.
The 8051 is now running in Idle mode and responds immediately to T5INT.
8051 leaves Idle mode, executes T5INT service routine (disables T5INT) and executes an IRET when done.
8051 returns to executing from where it left off prior to entering sleep mode. FIGURE 15 - EXITING SLEEP MODE
SMSC DS - FDC37N958FR
Page 163
Rev. 09/01/99
Wake-up Events Table 58 - System Wake-up Events LEVEL/EDGE INTERNAL OR WAKE-UP EVENTS SENSITIVE EXTERNAL nRI1, nRI2 Edge, high-to-low External nGPWKUP WK_HL1 WK_HL2 ACCESS.bus DATA going active WK_HL3 WK_HL4 WK_HL5 WK_EE1 RTC_ALRM (1) HTIMER WK_EE2 WK_EE3 WK_HL6 WK_EE4 WK_ANYKEY Edge, high-to-low Edge, high-to-low Edge, high-to-low Leading edge, high-to-low Edge, high-to-low Edge, high-to-low Edge, high-to-low Either edge Leading edge, low-to-high Leading edge, low-to-high Either edge Either edge Edge, high-to-low Either edge Edge, high-to-low External External External Internal External External External External Internal Internal External External External External Internal
PIN nRI1, nRI2 nGPWKUP WK_HL1 WK_HL2 AB_DAT WK_HL3 WK_HL4 WK_HL5 WK_EE1 N/A N/A WK_EE2 WK_EE3 WK_HL6 WK_EE4 N/A (function of KSI[7:0] pins) GPIO8/COMRX
DESCRIPTION UART ring indicator General purpose wakeup source
ACCESS.bus Interrupt
RTC alarm Hibernation timer
Any Keyboard Key pressed
WK_HL7 [IR_WAKEUP]
Edge, high-to-low
External
IRRX
WK_HL8 [IR_WAKEUP]
Edge, high-to-low
External
IR energy detected on the GPIO/COM-RX Receive pin. IR energy detected on the RRRX Receive pin.
SMSC DS - FDC37N958FR
Page 164
Rev. 09/01/99
WAKEUP SOURCE REGISTER 1 Host N/A 8051 0x7F2A (R) Power VCC1 Default 0x00 D7 R
1= WK_HL5
8051 R/W Def
D6 R
1= WK_HL2 occurs
D5 R
1= WK_HL1 occurs
D4 R
1= AB_DAT ACCESS. bus interrupt occurs (Note 3)
D3 R
1= WK_HL3 occurs
D2 R
1= WK_HL4 occurs
D1 R
1= WK_EE1 changed (Note 1)
D0 R
1= RTC_AL RM occurs (Note 2)
Note : All the bits in this register are cleared on a read of this register. Note 1: Input is going from low to high or from high to low (read the GPIO register to find out the value of pin) Note 2: The RTC_ALRM Wake-up is an internally-generated Low-to-High edge, produced when the RTC time updates to match the Time Of Day (TOD) alarm setting. This edge will set bit D0 of Wake-up Source 1 Register. Bit D0 will remain set and will only be reset on a read of Wakeup Source 1 Register. If the Wake-up source register is read before the clock has updated (i.e., RTC still equals the TOD alarm) bit D0 is reset and stays reset until the next occurrence of a RTC_ALRM Wake-up event. Note 3: ACCESS.bus Interrupt - When ACCESS.bus = 1, a start condition or other event was detected on the ACCESS.bus bus WAKEUP SOURCE REGISTER 2 Host N/A 8051 0x7F2B (R) Power VCC1 Default 0x00 D7 R
1= UART_ RI2 occurs
8051 R/W
Des.
D6 R
1= UART_ RI1 occurs
D5 R
1= WK_EE4
D4 R
1= WK_EE2 transition (both edges)
D3 R
1= WK_EE3 transition (both edges)
D2 R
1= HTIMER timeouts
D1 R
1= WK_HL6 active
D0 R
1= nGPWKUP is active
Note: All the bits in this register are cleared on a read of this register. HTIMER Interrupt -- When HTIMER=1, the hibernation timer counted down to "0".
WAKEUP SOURCE REGISTER 3 Host N/A
SMSC DS - FDC37N958FR
Page 165
Rev. 09/01/99
8051 Power Default D7 R N/A
Reserved 0
0x7F35 (R) VCC1 0x00 D4 R N/A
Reserved 0
8051 Access Host Access
Description
D6 R N/A
Reserved 0
D5 R N/A
Reserved 0
D3 R N/A
Reserved 0
D2 R N/A
1= WK_ HL8 is active
D1 R N/A
1= WK_ HL7 is active
D0 R N/A
1= WK_ ANYKEY is active
Note: All the bits in this register are cleared on a read of this register. Note 1: Anykey Wake-up (WK_ANYKEY) - When unmasked, the WK_ANYKEY will wake the 8051 from the Sleep state when any of the Keyboard Scan In (KSI) pins goes low. The boolean equation below defines the WK_ANYKEY function. WK_ANYKEY = !(KSI0 & KSI1 & KSI2 & KSI3 & KSI4 & KSI5 & KSI6 & KSI7) Note 2: IR Receive Activity Wake-up Events -- On the FDC37N958FR, GPIO8 or IRRX may be configured as an Infared receive pin. An independently-maskable wake-up function is available on each of these pins. When un-masked, a high-to-low edge transition on either of these pins will generate an 8051 wake-up event. WAKEUP MASK REGISTER 1 Host N/A 8051 0x7F2C Power VCC1 Default 0x00 D7 R/W 1= mask WK_HL 5 D6 R/W 1= mask WK_HL 2 D5 R/W 1= mask WK_HL 1 D4 R/W 1= mask AB_DA TACCE SS.BUS D3 R/W 1= mask WK_HL 3 D2 R/W 1= mask WK_HL 4 D1 R/W 1= mask WK_EE 1 D0 R/W 1= mask RTC_ ALARM
8051 R/W Description
SMSC DS - FDC37N958FR
Page 166
Rev. 09/01/99
WAKEUP MASK REGISTER 2 Host N/A 8051 0x7F2D Power VCC1 Default 0x00 D7 R/W 1= mask UART RI2 D6 R/W 1= mask UART_ RI1 D5 R/W 1= mask WK_EE 4 D4 R/W 1= mask WK_EE 2 D3 R/W 1= mask WK_EE 3 D2 R/W 1= mask HTIMER D1 R/W 1= mask WK_HL 6 D0 R/W 1= mask nGPWK UP
8051 R/W Des.
WAKEUP MASK REGISTER 3 Host N/A 8051 0x7F36 Power VCC1 Default 0xFF
D7 R/W N/A
Reserved 1
8051 access Host access Description
D6 R/W N/A
Reserved 1
D5 R/W N/A
Reserved 1
D4 R/W N/A
Reserved 1
D3 R/W N/A
Reserved 1
D2 R/W N/A 1= Mask WK_HL8
D1 R/W N/A 1= Mask WK_HL7
D0 R/W N/A 1= Mask WK_ ANYKEY
HTIMER REGISTER Host N/A 8051 0x7FF3 Power VCC1 Default 0x00 Hibernation Timer - This 8 bit binary count-down timer can be programmed for from 30 seconds to 128 minutes in 30 second increments. When it expires (reaches "0"), it stops (remains at "0") and causes a hardware event that will wake up the 8051. This timer is clocked by the 32 KHz clock and is powered by VCC1. Writing a nonzero value to this register starts the counter from that value.
SMSC DS - FDC37N958FR
Page 167
Rev. 09/01/99
KEYBOARD CONTROLLER 8042 Style Host Interface The universal keyboard controller uses the 80C51 microcontroller CPU core to produce a superset of the features provided by the industry-standard 8042 keyboard controller. Added features include two high-drive serial interfaces, and additional interrupt sources. The FDC37N958FR provides an industry standard 8042-style host interface to the 80C51 to emulate standard 8042 keyboard controller and
preserve software backward compatibility with the system BIOS. The FDC37C958's keyboard ISA interface is functionally compatible with the 8042-style host interface. It consists of the SD[0:7] data bus; the nIOR, nIOW and the KBD (Keyboard) Status register, KBD Data/Command Write register, and KBD Data Read register. Table 59 shows how the interface decodes the control signals. In addition to the above signals, the host interface includes keyboard and mouse IRQ's.
Table 59 - Keyboard Controller ISA I/O Address Map ISA ADDRESS 0x60 NIOW 0 1 0x64 0 1 NIOR 1 0 1 0 FUNCTION (NOTE 1, 2 ) Keyboard Data Write (C/D=0) Keyboard Data Read Keyboard Command Write (C/D=1) Keyboard Status Read
All addresses are qualified by AEN. Note 1: The Keyboard Interface can be enabled or disabled through the configuration registers. Note 2: These registers consist of three separate 8 bit registers: KBD Status, KBD Data/Command Write and KBD Data Read. Keyboard Data Write This is an 8 bit write only register. When written, the C/D status bit of the status register is cleared to zero and the IBF bit is set. Keyboard Data Read This is an 8 bit read only register. When read, the PBOBF and/or AUXOBF interrupts are cleared and the OBF flag in the status register is cleared. Keyboard Command Write This is an 8 bit write only register. When written, the C/D status bit of the status register is set to one and the IBF bit is set. Keyboard Status Read This is an 8 bit read only register. Refer to the description of the Status Register (7FF2H) for more information.
8051-to-Host Keyboard Communication The 8051 can write to the KBD Data Read register via address 7FF1H and 7FFAH (Aux Host Data Register) respectively. A write to
SMSC DS - FDC37N958FR
Page 168
Rev. 09/01/99
either of these addresses automatically sets bit 0 (OBF) in the Status register. A write to 7FF1H
also sets PCOBF. A write to 7FFAH also sets AUXOBF1 . See Table 60 below.
Table 60 - Host-Interface Flags 8051 ADDRESS 7FF1H (R/W) 7FFAH (W) FLAG PCOBF (KIRQ) output signal goes high AUXOBF1 (MIRQ) output signal goes high
HOST I/F DATA REGISTER Host ISA 0x60 8051 0x7FF1 Power VCC1 Default N/A The Input Data register and Output Data register are each 8 bits wide. A write to this 8 bit register by the 8051 will load the Keyboard Data Read Buffer, set the OBF flag and set the PCOBF output if enabled. A read of this register by the 8051 will read the data from the Keyboard Data or Command Write Buffer and clear the IBF flag. Refer to the PCOBF and Status register descriptions for more information.
HOST I/F COMMAND REGISTER Host ISA 0x64 (W) 8051 0x7FF1 Power VCC1 Default N/A The host CPU sends commands to the keyboard controller by writing command bytes to ISA port 0x64.
SMSC DS - FDC37N958FR
Page 169
Rev. 09/01/99
HOST I/F STATUS REGISTER Host ISA 0x64 (R) 8051 0x7FF2 Power VCC1 Default N/A The Status register is 8 bits wide. Shows the contents of the KBD Status register. Table 61 - KBD Status Register D7 UD D6 UD D5 AUXOBF/UD D4 UD D3 C/D D2 UD D1 IBF D0 OBF
This register is read-only for the Host and read/write by the 8051. The 8051 cannot write to bits 0, 1, or 3 of the Status register. UD Read/Writeable by 8051. user-definable. C/D Command Data - This bit specifies whether the input data register contains data or a command ("0" = data, "1" = command). During a host data/command write operation, this bit is set to "1" if SA2 = "1" or reset to "0" if SA2 = 0. IBF Input Buffer Full - This flag is set to "1" whenever the host system writes data into the input data register. Setting this flag activates the 8051's nIBF interrupt if enabled. When the 8051 reads the input data register, this bit is automatically reset and the interrupt is cleared. There is no output pin associated with this internal signal. These bits are OBF Output Buffer Full - This flag is set to "1" whenever the 8051 writes into the data registers at 7FF1H or 7FFAH. When the host system reads the output data register, this bit is automatically reset. AUXOBF Auxiliary Output Buffer Full - This flag is set to "1" whenever the 8051 writes into the data registers at 7FFAH. This flag is reset to "0" whenever the 8051 writes into the data registers at 7FF1H.
SMSC DS - FDC37N958FR
Page 170
Rev. 09/01/99
PCOBF Host N/A 8051 0x7FFD Power VCC1 Default 0x00 Refer to the PCOBF description for information on this register. This is a "1" bit register (bits 1-7=0 on read) Host-to 8051 Keyboard Communication The host system can send both commands and data to the KBD Data/Command Write register. The CPU differentiates between commands and data by reading the value of bit 3 of the Status register. When bit 3 is "1", the CPU interprets the register contents as a command. When Bit 3 is "0", the CPU interprets the register contents as data. During a host write operation, bit 3 is set to "1" if SA2 = 1 or reset to "0" if SA2 = 0. PCOBF Description (The following description assumes that OBFEN = 1 in Configuration Register 0); PCOBF is gated onto KIRQ. The KIRQ signal is a system interrupt which signifies that the 8051 has written to the KBD Data Read register via address 7FF1H. On power-up, PCOBF is reset to 0. PCOBF will normally reflect the status of writes to 7FF1H, if PCOBFEN (bit 2 of Configuration register "0") = "0". (KIRQ is normally selected as IRQ1 for keyboard support.) PCOBF is cleared by hardware on a read of the Host Data Register. The PCOBF register is also readable; bits 1-7 will return a "0" on the read back. The value read back on bit 0 of the register always reflects the present value of the PCOBF output. If PCOBFEN = 1, then this value reflects the output of the firmware latch at 7FFDH. If PCOBFEN = 0, then the value read back reflects the in-process status of write cycles to 7FF1H (i.e., if the value read back is high, the host interface output data register has just been written to). If OBFEN=0, then KIRQ is driven inactive (low). Additional flexibility has been added which allows firmware to directly control the PCOBF output signal, independent of data transfers to the host-interface data output register. This feature allows the FDC37N958FR to be operated via the host "polled" mode. This firmware control is active when PCOBFEN = 1 and firmware can then bring PCOBF high by writing a "1" to the LSB of the 1 bit data register, PCOBF, allocated at 7FFDH. The firmware must also clear this bit by writing a "0" to the LSB of the 1 bit data register at 7FFDH.
SMSC DS - FDC37N958FR
Page 171
Rev. 09/01/99
AUXOBF1 Description (The following description assumes that OBFEN = 1 in Configuration Register 0); This bit is multiplexed onto MIRQ. The AUXOBF1/MIRQ signal is a system interrupt which signifies that the 8051 has written to the output data register via address 7FFAH.
On power-up, after VCC1 POR, AUXOBF1 is reset to 0. AUXOBF1 will normally reflects the status of writes to 7FFAH. (MIRQ is normally selected as IRQ12 for mouse support.) AUXOBF1 is cleared by hardware on a read of the Host Data Register. If OBFEN=0, then KIRQ is driven inactive (low).
Write to Register 7FF1 7FFA
HOST I/F STATUS REGISTER BITS AUXOBF (D5) OBF (D0) 0 1 1 1 OBFEN 0 1 1 PCOBFEN x 0 1
OBFEN=0 KIRQ=0 MIRQ=0
OBFEN=1 KIRQ=1 MIRQ=1
KIRQ is inactive and driven low KIRQ = PCOBF@7FF1 KIRQ = PCOBF@7FFD
OBFEN 0 1 1
AUXH x 0 1
MIRQ is inactive and driven low MIRQ = PCOBF@7FFA; Status Register D5 = User Defined MIRQ = PCOBF@7FFA; Status Register D5 = Hardware Controlled
8051 AUXOBF1 Control Register AUX Host Data Register Host ISA 0x60 8051 0x7FFA Power VCC1 Default N/A Refer to the AUXOBF1 description for information on this register. GATEA20 Hardware Speed-Up GateA20 is multiplexed onto GPIO[17] using MISC6. The FDC37N958FR contains on-chip logic support for the GATEA20 hardware speedup feature. GATEA20 is part of the control required to mask address line A20 to emulate 8086 addressing. In addition to the ability for the host to control the GATEA20 output signal directly, a configuration bit called "SAEN" (Software Assist Enable, bit 1 of Configuration register 0) is provided; when set, SAEN allows firmware to control the GATEA20 output. When SAEN is set, a 1 bit register assigned to address 7FFBH controls the GATEA20 output. The register bit allocation is shown in Table 62.
SMSC DS - FDC37N958FR
Page 172
Rev. 09/01/99
D7 x
D6 x
Table 62 - Register Bit Allocation D5 D4 D3 D2 D1 x x x x x
D0 GATEA20
Writing a "0" into location D0 causes the GATEA20 output to go low, and vice versa. When the register at location 7FFBH is read, all unused bits (D7-D1) are read back as "0". Host control and firmware control of GATEA20 affect two separate register elements. Read back of GATEA20 through the use of 7FFBH reflects the present state of the GATEA20 output signal: if SAEN is set, the value read back corresponds to the last firmware-initiated control of GATEA20; if SAEN is reset, the value read back corresponds to the last host-initiated control of GATEA20. Host control of the GATEA20 output is provided by the hardware interpretation of the "GATEA20 sequence" (see Table 61). The foregoing description assumes that the SAEN configuration bit is reset. When the FDC37N958FR receives a "D1" command followed by data (via the host interface), the on-chip hardware copies the value of data bit 1 in the received data field to
the GATEA20 host latch. At no time during this host-interface transaction will PCOBF or the IBF flag (bit 1) in the Status register be activated; i.e., this host control of GATEA20 is transparent to firmware, with no consequent degradation of overall system performance. Table 63 details the possible GATEA20 sequences and the FDC37N958FR responses. On VCC1 POR, GATEA20 will be set. An additional level of control flexibility is offered via a memory-mapped synchronous set and reset capability. Any data written to 7FFEH causes the GATEA20 host latch to be set, while any data written to 7FFFH causes it to be reset. This control mechanism should be used with caution. It was added to augment the "normal" control flow as described above, not to replace it. Since the host and the firmware have asynchronous control capability of the host latch via this mechanism, a potential conflict could arise. Therefore, after using the 7FFEH and 7FFFH addresses, firmware should read back the GATEA20 status via 7FFBH (with SAEN = 0) to confirm the actual GATEA20 response.
SMSC DS - FDC37N958FR
Page 173
Rev. 09/01/99
Table 63 - GATE20 Command/Data Sequence Examples IBF GATEA20 COMMENTS SA2 R/W D[0:7] GATEA20 Turn-on Sequence Q 0 D1 W 1 1 0 DF W 0 1 0 FF W 1 GATEA20 Turn-off Sequence Q 0 D1 W 1 0 0 DD W 0 0 0 FF W 1 GATEA20 Turn-on Sequence(*) Q 0 D1 W 1 Q 0 D1 W 1 1 0 DF W 0 1 0 FF W 1 GATEA20 Turn-off Sequence(*) Q 0 D1 W 1 Q 0 D1 W 1 0 0 DD W 0 0 0 FF W 1 Invalid Sequence Q 0 D1 W 1 Q 1 XX** W 1 Q 1 FF W 1 Notes: All examples assume that the SAEN configuration bit is 0. "Q" indicates the bit remains set at the previous state. *Not a standard sequence. **XX = Anything except D1. If multiple data bytes, set IBF and wait at state 0. Let the software know something unusual happened. For data bytes SA2=0, only D[1] is used; all other bits are don't care.
SMSC DS - FDC37N958FR
Page 174
Rev. 09/01/99
8051 GATEA20 Control Registers GATEA20 Host N/A 8051 0x7FFB Power VCC1 Default 0x01 Refer to the GATEA20 Hardware Speed-up description for information on this register. This is a one bit register (Bits 1-7=0 on read) SETGA20L Host N/A 8051 0x7FFE (W) Power VCC1 Default N/A Refer to the GATEA20 Hardware Speed-up description for information on this register. A write to this register sets GateA20. RSTGA20L Host N/A 8051 0x7FFF (W) Power VCC1 Default N/A Refer to the GATEA20 Hardware Speed-up description for information on this register. A write to this register re-sets GateA20.
SMSC DS - FDC37N958FR
Page 175
Rev. 09/01/99
GateA20 Logic
SAEN 64&nAEN nIOW_DLY nIOW DD1 SD[7:0] = D1 Address SD[7:0] = FF Data SD[7:0] = FE nAEN&60 SETGA20L Reg Any Write DD1 D nIOW nAEN&64 nIOW nAEN&60 D Trailing Edge Delay Q After D1 SD[1] S Fast_GateA20 DFE 0 MUX 1 DFF CPU_RESET D Q IBF Bit IBF nIOW nIOW nIOW_DLY To KRESET Gen
A20
GATEA20
D
Q
SAEN bit-1 of Config Reg 0
R RSTGA20L Reg Any Write
R Write
GATEA20 Reg d0 GATEA20 Reg d0
bit-0
Read
bit-0
Port92 Reg ENAB_P92 Bit 1 ALT_A20
VCC nIOW D 24MHz Q D Q nIOW_DLY
Delay
D R nQ
FIGURE 16 - GATEA20 IMPLEMENTATION DIAGRAM CPU_RESET Hardware Speed-Up The ALT_CPU_RESET bit generates, under program control, the nALT_RST signal which provides an alternate means to drive the FDC37N958FR CPU_RESET pin which in turn is used to reset the Host CPU. The nALT_RST signal is internally NANDed together with the nKBDRESET pulse from the KRESET Speed up logic to provide an alternate software means of resetting the host CPU. Note: before another nALT_RST pulse can be generated, ALT_CPU_RESET must be cleared to "0" either by a system reset (RESET_OUT asserted) or by a write to the Port92 register with bit 0 = "0". An nALT_RST pulse is not generated in the event that the ALT_CPU_RESET bit is cleared and set before the prior nALT_RESET pulse has completed.
SMSC DS - FDC37N958FR
Page 176
Rev. 09/01/99
14 us 6us
FE Command From KRESET Speed up Logic
SAEN KRESET Pulse Gen CPU_RESET
Port92 Reg
ENAB_P92
Bit 0
Pulse Gen
nALT_RST
14 us 6us
FIGURE 17 - CPU_RESET IMPLEMENTATION DIAGRAM
SMSC DS - FDC37N958FR
Page 177
Rev. 09/01/99
Port 92 The FDC37N958FR supports ISA I/O writes to port 92h as a quick alternate mechanism for generating a CPU_RESET controlling the state of GATEA20. pulse or
Host R/W Bit Def
PORT 92 REGISTER DESCRIPTION D7-D2 D1 D0 R/W R/W R/W 0 ALT_GATEA20 ALT_CPU_RESET Reserved = 1: ALT_A20 is driven high When Port 92 is enabled, writing a 0 to bit 1 of the Port92 Register forces ALT_A20 low. ALT_A20 low drivesGATEA20 low, if A20 from the keyboard controller is also low. When Port 92 is enabled, writing a 1 to bit 1 of the Port92 register forces ALT_A20 high. ALT_A20 high drives GATEA20 high regardless of the state of A20 from the keyboard controller. D0 - ALT_CPU_RESET This bit provides an alternate means to generate a CPU_RESET pulse. The CPU_RESET output provides a means to reset the system CPU to effect a mode switch from Protected Virtual Address Mode to the Real Address Mode. This provides a faster means of reset than is provided through the 8051 keyboard controller. Writing a "1" to this bit will cause the nALT_RST internal signal to pulse (active low) for a minimum of 6"s after a delay of 14"s. Before another nALT_RST pulse can be generated, this bit must be written back to "0".
The Port92h register resides at ISA address 0x92 and is used to support the alternate reset (nALT_RST) and alternate GATEA20 (ALT_A20) functions. This register defaults to 0x00 on assertion of RESET_OUT or on VCC2 Power On Reset. The Port92h Register is enabled by setting the Port 92 Enable bit (bit 0 of Logical Device 7 Configuration Register 0xF0). When Port92 is disabled, by clearing the Port 92 Enable bit, then access to this register is completely disabled (I/O writes to ISA 92h are ignored and I/O reads float the system data bus SD[7:0]). When Port92h is enabled the bits have the following meaning: D7-D2 Reserved Writes are ignored and reads return 0. D1 - ALT_GATEA20 This bit provides an alternate means for system control of the FDC37N958FR GATEA20 pin. = 0: ALT_A20 is driven low
SMSC DS - FDC37N958FR
Page 178
Rev. 09/01/99
Direct Keyboard Scan The FDC37N958FR scanning keyboard controller is designed for intelligent keyboard
management in computer applications. By properly configuring GPIO4 and GPIO5, the FDC37N958FR may be programmed to directly control keyboard interface matrixes of up to 16x8.
KEYBOARD SCAN-OUT REGISTER Host N/A 8051 0x7F04 (W) Power VCC1 Default 0x20 D3 D2 D1 D0 W W W W D5 and D4 must be `0' D[3:0] = 0000 KSO[0] is asserted low D[3:0] = 0001 KSO[1] is asserted low D[3:0] = 0010 KSO[2] is asserted low D[3:0] = 0011 KSO[3] is asserted low ! ! ! D[3:0] = 1101 KSO[13] is asserted low D[3:0] = 1110 KSO[14] is asserted low D[3:0] = 1111 KSO[15] is asserted low 1 = disable scanning of internal keyboard (all the KSOUT lines going high) (D4-D0 are don't cares) 0 = enable scanning of internal keyboard To support KSO14 and KSO15, GPIO4 and GPIO5 must be configured properly. KEYBOARD SCAN-IN REGISTER Host N/A 8051 0x7F04 (R) Power VCC1 Default N/A D7-D0 8051 R R Bit description Reflects the state of KSI [7:0] The value of the KSI[x] pins can be read through this register. The pin values are latched during the read. D7-D6 W N/A D5 W KSEN D4 W 1 = forces all KSO lines to go low
8051 R/W Bit Def
KSEN Note:
SMSC DS - FDC37N958FR
Page 179
Rev. 09/01/99
EXTERNAL INTERFACE
KEYBOARD
AND
MOUSE
Industry-standard PC/AT-compatible keyboards employ a two-wire, bidirectional TTL interface for data transmission. Several sources also supply PS/2 mouse products that employ the same type of interface. To facilitate system expansion, the FDC37N958FR provides four pairs of signal pins that may be used to implement this interface directly for an external keyboard and mouse. The FDC37N958FR has four high-drive, opendrain output (external pull-ups are required),
bidirectional port pins that can be used for external serial interfaces, such as ISA external key-board and PS/2-type mouse interfaces. They are KBCLK, KBDAT, EMCLK, EMDAT, IMCLK, IMDAT, PS2CLK and PS2DAT. The following function is assumed to be in the PS/2 PORT logic: The serial clock lines, KBCLK, EMCLK, IMCLK and PS2CLK, are cleared to a low by VCC2 POR. This is so that any power-on self-test completion code transmitted from the serial keyboard will not be missed by the FDC37N958FR due to power-up timing mismatches.
SMSC DS - FDC37N958FR
Page 180
Rev. 09/01/99
Mailbox Register Interface The FDC37N958FR provides a set of 16 8 bit registers, called mailbox registers, by which the Host CPU may communicate with the 8051. These registers are accessible to the host in configuration Mode or through the open mode Index and Data Registers also described in Configuration section. At the same time these registers are accessible to the 8051 through 16 memory mapped control registers. Fourteen of these mailbox registers are general purpose and are typically used to pass status and parameters. The remaining two mailbox registers (mbox-0: System-to-8051, and mbox-1: 8051-toSystem) are specifically designed to pass commands and to provide a means for each to interrupt the other assuming interrupts are unmasked. These registers are not "dualported" meaning that the system BIOS and keyboard BIOS must be designed to properly share these registers. Note: When the Host CPU performs a write of the System-to-8051 mailbox register an 8051
INT1 will be generated and seen by the 8051 if unmasked. When the 8051 writes to the System-to-8051 mailbox register the data is blocked but the write forces the System-to-8051 register to clear to "0", providing a means for the 8051 to inform that Host that an operation has been completed. When the 8051 performs a write of the 8051-toSystem mailbox register an SMI may be generated and seen by the Host if unmasked. When the host CPU writes to the 8051-toSystem mailbox register the data is blocked but the write forces the 8051-to-System register to clear to zero, providing a means for the host to inform that 8051 that an operation has been completed. The protocol used to pass commands back and forth through the mailbox interface is left to the system designer. SMSC can provide an application example of working code in which the host uses the mailboxes to gain access to all of the 8051 access only registers.
SMSC DS - FDC37N958FR
Page 181
Rev. 09/01/99
System-to-8051 8051-to-System
SMI
INT1
HOST CPU
14, 8 bit Mailbox Registers
FIGURE 18 - MAILBOX BLOCK DIAGRAM REGISTER DESCRIPTION
8051
SYSTEM-TO-8051 MAILBOX REGISTER 0 Host IDX 0x82 8051 0x7F08 (RC) Power VCC1 Default 0x00 RC = Read only register is cleared upon a read. If enabled, an INT1 will be generated when the system writes to this register. The Interrupt source bit will be cleared when the 8051 reads this register. After reading this register the 8051 (8051) can clear the register's content by a dummy write to this register to signal to the system that the register has been read.
8051-TO-SYSTEM MAILBOX REGISTER 1 Host IDX 0x83 (RC) 8051 0x7F09 Power VCC1 Default 0x00 If enabled by ESMI register, an SMI will be generated when the 8051 writes to this register. The SMI interrupt will be cleared when the Host reads this register. After reading this register the system can clear the register's content by a dummy write to this register to signal to the 8051 that the register has been read.
SMSC DS - FDC37N958FR
Page 182
Rev. 09/01/99
MAILBOX REGISTER 2-F Host IDX 0x84 - 0x91 8051 0x7F0A - 0x7F17 Power VCC1 Default 0x00 These registers are readable and writeable from both the 8051 and the system. The system and the 8051 codes must make sure these registers are not inadvertently overwritten. MAILBOX SMI INTERRUPT The host can enable/disable SMI interrupts generated as a result of the 8051 writing to Mailbox Register 1. The Host can read the ESMI source register to determine if the FDC37N958FR Mailbox Interface was the cause of the SMI.
ESMI MASK REGISTER Host IDX 0x97 (R) 8051 N/A Power VCC2 Default 0x00 D7-D4 N/A R Reserved D3 N/A R/W 1 = mask the 8051-to-system mailbox SMI ESMI Source Register Host IDX 0x96 8051 N/A Power VCC2 Default 0x00 D2-D0 N/A R Reserved
8051 R/W System R/W Bit Def
8051 R/W System R/W Bit Def
D7-D4 N/A R Reserved
D3 N/A R/W 1 = 8051-to-system mailbox has been written to. This bit is cleared by a read of Mailbox Register 1
D2-D0 N/A R Reserved
SMSC DS - FDC37N958FR
Page 183
Rev. 09/01/99
PS/2 INTERFACE DESCRIPTION
PS/2 PORT CONTROL REGISTERS Port 1 Port 2 Host N/A N/A 8051 0x7F41 0x7F49 Power VCC2 VCC2 Default 0x00 0x00 D7 R
Reserved Reserved
R/W PS/2 port1 PS/2 port2
D6 R
Reserved Reserved
D5 R
Reserved Reserved
D4 R/W EM_EN IM_EN
D3 R/W KB_EN PS2_EN
D2 R/W Inhibit Inhibit
D1 R/W RX_EN RX_EN
D0 R/W TX_EN TX_EN
Only one of bits 2-0 can be set to one. PS/2 PORT STATUS REGISTERS Port 1 Port 2 Host N/A N/A 8051 0x7F42 (R) 0x7F4A (R) Power VCC2 VCC2 Default 0x00 0x00 D7 R
Reserved Reserved
R/W PS/2 port1 PS/2 port2
D6 R
Reserved Reserved
D5 R
EM_busy
D4 R KB_busy PS2_busy
IM_busy
D3 R Inhibit done Inhibit done
D2 R EM_drdy IM_drdy
D1 R KB_drdy
PS2_drdy
D0 R Error Error
SMSC DS - FDC37N958FR
Page 184
Rev. 09/01/99
PS/2 PORT ERROR STATUS REGISTERS Port 1 Port 2 Host N/A N/A 8051 0x7F43 (R) 0x7F4B (R) Power VCC2 VCC2 Default 0x00 0x00 D7-D5 R
Reserved
R/W
Bit Def
D4 R
Parity
D3 R
RES_timeout
D2 R
REC_timeout
D1 R
RTS_timeout
D0 R
XMT_timeout
PS/2 PORT TANSMIT REGISTERS Port 1 Port 2 Host N/A N/A 8051 0x7F44 (W) 0x7F4C (W) Power VCC2 VCC2 Default 0x00 0x00 D7 W D6 W D5 W D4 W D3 W D2 W D1 W D0 W
R/W
PS/2 PORT RECEIVE REGISTERS Port 1 Port 2 Host N/A N/A 8051 0x7F45 (R) 0x7F4D (R) Power VCC2 VCC2 Default 0x00 0x00 D7 R D6 R D5 R D4 R D3 R D2 R D1 R D0 R
R
ACCESS.bus Interface Description The ACCESS.Bus interface is fully and directly controlled by the on-chip 8051 through its set of on-chip memory mapped control registers. The
ACCESS.bus logic is based on the PCF8584 I2C controller and is powered on the VCC1 powerplane to provide the ability to wake-up the 8051 on an ACCESS.bus event.
SMSC DS - FDC37N958FR
Page 185
Rev. 09/01/99
Memory Mapped Control Registers ACCESS.BUS CONTROL REGISTER Host N/A 8051 0x7F31 (W) Power VCC1 Default 0x00 D7 D6 D5 D4 D3 D2 D1 D0 8051 R/W W W W W W W W W Bit Def PIN ES0 Reserved Reserved ENI STA STO ACK Bit 7 PIN: Pending Interrupt Not - Writing this bit to a logic "1" deasserts all status bits except for nBB (Bus Busy), nBB is not affected. This is a self-clearing bit. Writing this bit to a logic "0" has no effect. ACCESS.BUS STATUS REGISTER Host N/A 8051 0x7F31 (R) Power VCC1 Default 0x81 D7 R PIN D6 R 0 D5 R STS D4 R BER D3 R LRB D2 R AAS D1 R LAB D0 R nBB
8051 R/W Bit Def
ACCESS.BUS OWN ADDRESS REGISTER Host N/A 8051 0x7F32 Power VCC1 Default 0x00 D7 R/W
Reserved
8051 R/W Bit Def
D6 R/W Slave Address 6
D5 R/W Slave Address 5
D4 R/W Slave Address 4
D3 R/W Slave Address 3
D2 R/W Slave Address 2
D1 R/W Slave Address 1
D0 R/W Slave Address 0
SMSC DS - FDC37N958FR
Page 186
Rev. 09/01/99
ACCESS.BUS DATA REGISTER Host N/A 8051 0x7F33 Power VCC1 Default 0x00 D7 R/W D6 R/W D5 R/W D4 R/W D3 R/W D2 R/W D1 R/W D0 R/W
8051 R/W
ACCESS.BUS CLOCK REGISTER Host N/A 8051 0x7F34 Power VCC1 Default 0x00 ACCESS.BUS CLOCK D6-D2 D1 D0 8051 R/W R R/W R/W Reserved 00 - clock off (default) 01 - 32 KHz clock 10 - 8051 clock 11 - 24 MHz clock (*) ACCESS.bus Reset, not self-clearing, must be written high and then written low. D7 R/W AB_RST* Bit 7 AB_RST: (ACCESS.bus Reset) setting this bit re-initializes all logic and registers in the ACCESS.bus block.
SMSC DS - FDC37N958FR
Page 187
Rev. 09/01/99
ACCESS. bus CLOCK D[1:0] 00 10
Table 64 - ACCESS.bus Clock Rates DATA NOMINAL NOMINAL CLOCK RATE RATE HIGH LOW Off Ring Osc Ring Osc=4 MHz Ring Osc=6 MHz Ring Osc=8 MHz 12 MHz 14.3 MHz 16 MHz 24 MHz
MINIMUM HIGH
10 10 10 11
f/240 96/f 144/f 16.7 KHz 24"s 36"s 25 KHz 16"s 24"s 33.3 KHz 12"s 18"s 50 KHz 8"s 12"s 60 KHz 6.7"s 10.1"s 67 KHz 6"s 9"s 100 KHz 4"s 6"s f = frequency of the ring oscillator.
18/f 4.5"s 3"s 2.25"s 4"s 4"s 4"s 4"s
SMSC DS - FDC37N958FR
Page 188
Rev. 09/01/99
LED Controls
The FDC37N958FR has three independent LED outputs that are programmable under 8051 control. LED Register N/A 0x7F21 VCC1 see note 2 D4 N/A R status of pin MODE D3 0 R/W PWR_ LED1 D2 0 R/W PWR_ LED0 D1 0 R/W BAT_ LED1 D0 0 R/W BAT_ LED0
Host 8051 Power Default D7 0 R/W FDD Led Enable
Note 1
Default 8051 access Bit def
D6 0 R/W FDD_ LED1
D5 0 R/W FDD_L ED0
00 FDD LED is off 01 LED flash; P=1.0 sec 10 LED flash; P=0.5 sec 11 LED is fully on
00 PWR LED is off 01 LED flash; P=3.0 sec 10 LED flash; P=1.5 sec 11 LED is fully on
00 Battery LED is off 01 LED flash; P=1.0 sec 10 LED flash; P=0.5 sec 11 LED is fully on
Note 1: D7 =1; FDD_LED Pin is controlled by D6, D5 D7=0; FDD_LED is controlled by the Motor Enable 0 pin from the FDC. When Motor Enable 0 pin is asserted the LED is on. LED on time is T=125msec; "0" is on, "1" is off. Period "P" is indicated above. Note 2: This register is impacted by a device functional revision. See FUNCTIONAL REVISION ADDENDUM on page 308 for VCC1 and VCC2 POR impact and default values.
P T
FIGURE 19 - LED OUTPUT
SMSC DS - FDC37N958FR
Page 189
Rev. 09/01/99
Pulse Width Modulators
The FDC37N958FR has two independent Pulse Width Modulator outputs that are programmable under 8051 control. PWM0 REGISTER Host IDX 0x92 8051 0x7F25 Power VCC1 Default 0x00
D7 0 select MHz 1 select MHz = 2 = 3
D6
D5
D4
D3
D2
D1
D0
These 7 bits control the duty cycle of pin PWM0 (FAN_SPD) 0000000 = pin is low 0111111 = 50% duty cycle (32"s on/ 32 us off if 2 MHz is used) 1111111 = pin is high for 127, low for 1
PWM1 REGISTER Host IDX 0x93 8051 0x7F26 Power VCC1 Default 0x00 D7 0 = select 2 MHz 1 = select 3 MHz D6 D5 D4 D3 D2 D1 D0
These 7 bits control the duty cycle of pin PWM1 0000000 = pin is low 0111111 = 50% duty cycle (32"s on/ 32 us off if 2 MHz is used) 1111111 = pin is high for 127, low for 1
Real Time Clock CMOS Access RTCCNTRL (RTC CONTROL) REGISTER Host N/A 8051 0x7FF5 Power VCC1 Default 0x80
SMSC DS - FDC37N958FR
Page 190
Rev. 09/01/99
The FDC37N958FR implements an interface that allows the 8051 to read/write the RTC and CMOS registers. When RESET_OUT is active D7 nSH nSH D6 0 D5 0 D4 0 D3 KREQH
or when VCC2 is off, the 8051 can read and write the CMOS.
D2 HREQH
D1 KREQL
D0 HREQL
nSmart Host - This bit is controlled by the 8051. When set to a "1", the host is not a smart host and does not recognize the sharing protocol. When set to a "0", the host is smart and can recognize the sharing protocol. When set to "1", this bit will clear HREQH and HREQL. Clearing this bit to "0" will allow the 8051 to regain access to the CMOS RAM. Keyboard Request Low - This bit can be set by the 8051 when HREQL IS '0'. If the request is not granted, this bit is read back as a zero and the request must be tried again. Note: After regaining control of the CMOS, the 8051 must re-write the RTC Address register before accessing the RTC Data Register. This bit selects access to the CMOS RAM Addresses 0-7F. Host Request Low - This bit can be set by the host when KREQL is "0". If the request is not granted, this bit is read back as a "0" and the request must be tried again. Keyboard Request High - This bit can be set by the 8051 when HREQH is "0" If the request is not granted, this bit is read back as a "0" and the request must be tried again. Note: After regaining control of the CMOS, the 8051 must re-write the RTC Address register before accessing the RTC Data Register. This bit selects access to the CMOS RAM Addresses 80FF. Host Request High - This bit can be set by the host when KREQH is "0". If the request is not granted, this bit is read back as a "0" and the request must be tried again. NSH 1 0 0 0 KREQX x 0 1 0 HREQX x 0 0 1 BUS ACCESS Host None 8051 Host
KREQL
HREQL
KREQH
HREQH
SMSC DS - FDC37N958FR
Page 191
Rev. 09/01/99
RTC ADDRESS REGISTER (HIGH AND LOW) Host N/A 8051 0x7FF8 & 0x7FF6 Power VCC1 Default 0x00 & 0x00 The low register is used to provide the address for the first bank of 128 CMOS RAM registers and the high register is used to provide the address for the second bank of 128 CMOS RAM registers for a total of 256 registers. This register is used to select the CMOS address when KREQ=1. CMOS register 7F is a control register that reflects the RTC Control register and cannot be used as general purpose storage. Bit D7 is not used for the address decode and is a don't care bit.
RTC DATA REGISTER (HIGH AND LOW) Host N/A 8051 0x7FF9 & 0x7FF7 Power VCC1 Default 0x00 & 0x00 The low register is used to access the first bank of 128 bytes, in CMOS RAM the high register is used to access the second bank of 128 registers. This register is used to read or write the selected CMOS register when KREQ=1.
SMSC DS - FDC37N958FR
Page 192
Rev. 09/01/99
8051 CONTROLLED PARALLEL PORT To facilitate activities such as reprogramming the Flash Memory without opening the unit, the 8051 is able to take control of the parallel port interface. The 8051 has three memory mapped registers that look like the host's standard
parallel port registers (Status, Control, and Data) with the exception that the 8051's Parallel Port Status register contains a write bit (bit 0) that allows the 8051 to disconnect the interface from the host and take control. Refer to the Parallel Port section for more information.
FIGURE 20 - PARALLEL PORT MULTIPLEXOR
From/to Host Parallel Port Interface 1 From/to 8051 Parallel port interface 0 SEL 1 Parallel Port
PP_HA
Parallel Port Connector
SMSC DS - FDC37N958FR
Page 193
Rev. 09/01/99
Operation Registers
The 8051 uses the following three memory mapped registers to gain access to and control the parallel port interface. PARALLEL PORT STATUS Register Host N/A 8051 0x7F3A Power VCC2 Default 0x00
PP_HA 1 = Host (or FDC) controls the Parallel Port Interface. 0 = 8051 controls the Parallel Port Interface (default). If 8051 access to the parallel port pins is enabled; The level of the parallel port status pins can be read by reading this register. Bit D7 (nBUSY): Bit D6 (nACK): Bit D5 (PE): Bit D4 (SLCT): Bit D3 (nERR): reflects the inverse state of pin BUSY reflects the current state of pin nACK reflects the current state of pin PE represents the current state of pin SLCT reflects the current state of pin nERR
8051 R/W System R/W Bit Def
D7 R N/A nBUSY
D6 R N/A nACK
D5 R N/A PE
D4 R N/A SLCT
D3 R N/A nERR
D2 R N/A 0
D1 R N/A 0
D0 R/W N/A
SMSC DS - FDC37N958FR
Page 194
Rev. 09/01/99
PARALLEL PORT CONTROL REGISTER Host N/A 8051 0x7F3B Power VCC2 Default 0x00 D7 R/W N/A 0 D6 R/W N/A 0 D5 R/W N/A PCD D4 R/W N/A 0 D3 R/W N/A SLCTIN D2 R/W N/A nINIT D1 R/W N/A AUTOFD D0 R/W N/A STROBE
8051 R/W System R/W Bit Def
If 8051 access to the parallel port pins is enabled. The value of STROBE, AUTOFD and SLCTIN are inverted and output onto the parallel port control pins. The value of nINIT is output
onto the parallel port control pins. If PCD (Parallel Control Direction) = 0, the data bus is output. If PCD = 1 the parallel port data bus is floating to allow read data in.
PARALLEL PORT DATA REGISTER Host N/A 8051 0x7F3C Power VCC2 Default 0x00 D7 R/W N/A PD7 D6 R/W N/A PD6 D5 R/W N/A PD5 D4 R/W N/A PD4 D3 R/W N/A PD3 D2 R/W N/A PD2 D1 R/W N/A PD1 D0 R/W N/A PD0
8051 R/W System R/W Bit Def
If 8051 access to the parallel port pins is enabled; When read, this register reads the logic
levels on the parallel port pins.
SMSC DS - FDC37N958FR
Page 195
Rev. 09/01/99
8051 Controlled IR Port It is possible to give direct control of the IRRX and IRTX pins to the 8051 by setting bit 2 of the
Multiplexing_1 Register. The 8051 communicates to the pins through its memory mapped IR Data Register shown here.
IR DATA REGISTER Host IDX 0x98 8051 N/A Power VCC2 Default 0x00 D7-D2 N/A R/W Reserved D1 N/A R IR_REC D0 N/A R/W IR_TX
8051 R/W System R/W Bit Def
Bit 1 and bit 0 are don't care if bit 2 of the Multiplexing_1 Register is reset. (These bits are
multiplexed onto the IRTX and IRRX pins when bit 2 of the Multiplexing Register is set).
SMSC DS - FDC37N958FR
Page 196
Rev. 09/01/99
General Purpose I/O (GPIO)
FIGURE 21 - OUTPUT PIN TYPE
OUTPUT EN ALT FUNC Control bit ALT FUNC OUTPUT nRD nWR GPIO OUT REG BIT 1 0 OUT PIN
FIGURE 22 - INPUT PIN TYPE
nRD
IN REG BIT IN PIN Wake-up Source Bit Edge detector
nWR Wake-up IRQ
nRD nWR
Wake-up Mask Bit
GPIO DIR BIT ALT FUNC Control bit ALT FUNC OUTPUT GPIO OUT REG BIT 1 0 GPIO PIN
GPIO IN REG BIT
ALT FUNC INPUT
SMSC DS - FDC37N958FR
Page 197
Rev. 09/01/99
FIGURE 23 - GPIO PIN TYPE Memory Mapped Control Registers GPIO DIRECTION REGISTER A Host N/A 8051 0x7F18 Power VCC1 Default 0x00 D7 GPIO7 1=output 0=input D6
GPIO6 1=output 0=input
D5
GPIO5 1=output 0=input
D4
GPIO4 1=output 0=input
D3
GPIO3 1=output 0=input
D2
GPIO2 1=output 0=input
D1
GPIO1 1=output 0=input
D0
GPIO0 1=output 0=input
Bit Def
SMSC DS - FDC37N958FR
Page 198
Rev. 09/01/99
GPIO INPUT REGISTER A Host N/A 8051 0x7F1A (R) Power VCC1 Default N/A D7 status of pin GPIO7 D6 status of pin GPIO6 D5 status of pin GPIO5 D4 status of pin GPIO4 D3 status of pin GPIO3 D2 status of pin GPIO2 D1 status of pin GPIO1 D0 status of pin GPIO0
Bit Des.
GPIO OUTPUT REGISTER A Host N/A 8051 0x7F19 Power VCC1 Default 0x00 D7 GPIO7 D6 GPIO6 D5 GPIO5 D4 GPIO4 D3 GPIO3 D2 GPIO2 D1 GPIO1 D0 GPIO0
Bit Des.
GPIO DIRECTION REGISTER B Host N/A 8051 0x7F1B Power VCC1 Default 0x00 D7 Bit Def.
GPIO15 1=output 0=input
D6
GPIO14 1=output 0=input
D5
GPIO13 1=output 0=input
D4
GPIO12 1=output 0=input
D3
GPIO11 1=output 0=input
D2
GPIO10 1=output 0=input
D1
GPIO9 1=output 0=input
D0
GPIO8 1=output 0=input
SMSC DS - FDC37N958FR
Page 199
Rev. 09/01/99
GPIO OUTPUT REGISTER B Host N/A 8051 0x7F1C Power VCC1 Default 0x00 D7 GPIO 15 D6 GPIO 14 D5 GPIO 13 D4 GPIO 12 D3 GPIO 11 D2 GPIO 10 D1 GPIO 9 D0 GPIO 8
Bit Def.
GPIO INPUT REGISTER B Host N/A 8051 0x7F1D (R) Power VCC1 Default N/A D7 status of pin GPIO15 D6 status of pin GPIO14 D5 status of pin GPIO13 D4 status of pin GPIO12 D3 status of pin GPIO11 D2 status of pin GPIO10 D1 status of pin GPIO9 D0 status of pin GPIO8
Bit Def.
GPIO DIRECTION REGISTER C Host N/A 8051 0x7F1E Power VCC1 Default 0x00 on VCC2 POR D7 0 D6 0 D5
GPIO21 1=output 0=input
D4
GPIO20 1=output 0=input
D3
GPIO19 1=output 0=input
D2
GPIO18 1=output 0=input
D1
GPIO17 1=output 0=input
D0
GPIO16 1=output 0=input
Bit Des.
SMSC DS - FDC37N958FR
Page 200
Rev. 09/01/99
GPIO OUTPUT REGISTER C Host N/A 8051 0x7F1F Power VCC1 Default 0x00 on VCC2 POR D7 0 D6 0 D5 GPIO21 D4 GPIO20 D3 GPIO19 D2 GPIO18 D1 GPIO17 D0 GPIO16
Bit Def.
GPIO INPUT REGISTER C Host N/A 8051 0x7F20 (R) Power VCC1 Default N/A D7 0 D6 0 D5 status of pin GPIO21 D4 status of pin GPIO20 D3 status of pin GPIO19 D2 status of pin GPIO18 D1 status of pin GPIO17 D0 status of pin GPIO16
Bit Def.
OUT REGISTER D Host N/A 8051 0x7F22 Power VCC1 Default 0xFF on VCC2 POR D7 OUT7 D6 OUT6 D5 OUT5 D4 OUT4 D3 OUT3 D2 OUT2 D1 OUT1 D0 OUT0
Bit Def.
SMSC DS - FDC37N958FR
Page 201
Rev. 09/01/99
OUT REGISTER E Host N/A 8051 0x7F23 Power VCC1 Default 0x0F on VCC2 POR D7 0 D6 0 D5 0 D4 0 D3 OUT11 D2 OUT10 D1 OUT9 D0 OUT8
Bit Def.
Host 8051 Power Default D7 status of pin IN7 D6 status of pin IN6 D5 status of pin IN5
IN REGISTER F N/A 0x7F24 (R) VCC1 N/A D4 status of pin IN4 D3 status of pin IN3 D2 status of pin IN2 D1 status of pin IN1 D0 status of pin IN0
Bit Def.
SMSC DS - FDC37N958FR
Page 202
Rev. 09/01/99
Multiplexed Pins Many of the FDC37N958FR's GPIO pins provide specific alternate functions which may be enabled by the 8051 firmware based on the design of the system in which the part will be used.
List Refer to the Alternate Function Pin List on page 12 for a complete list of all of the FDC37N958FR multifunction pins. Control Registers The 8051 firmware controls the multiplexing functions for each of the multiplexed pins on the FDC37N958FR through the registers described in this section. MULTIPLEXING_1 REGISTER Host N/A 8051 0x7F3D Power VCC1 Default 0x00
8051 R/W Bit Def
D7 R/W MISC7
D6 R/W MISC6
D5 R/W MISC5
D4 R/W MISC4
D3 R/W MISC3
D2 R/W MISC2
D1 R/W MISC1
D0 R/W MISC0
PIN IRQ6 (FDC)/OUT0 nIRQ8/OUT1 IRQ7 (PP)/OUT2 IRQ12 (Mouse)/OUT3 IRQ1(KBD)/OUT4 nSMI/OUT7 SIRQ/IRQ3 (UA1)
MISC0 = 0 (DEFAULT) OUT0 OUT1 OUT2 OUT3 OUT4 OUT7 SIRQ
MISC0 = 1 IRQ6 (FDC) nIRQ8 IRQ7 (PP) IRQ12(Mouse) IRQ1(KBD) nSMI IRQ3 (UA1)
SMSC DS - FDC37N958FR
Page 203
Rev. 09/01/99
PIN GPIO[20] PIN GPIO[21] PIN 52 PIN 53 GPIO[20] + GPIIO[21] 8051_RX * [0,1] PS2CLK PS2DAT [1,0] GPIO[20] + 8051_TX ** 8051_RX * [1,1] PS2CLK PS2DAT * GPIO20_DIR bit should be set to 0 when operating as an 8051_RX pin. ** GPIO21_DIR bit must be set to 1 when operating as an 8051_TX pin. MISC[3,1] [0,0] (default) The PS/2 pins on GPIO20 and GPIO21 are disabled (internally pulled high) when the non PS/2 alternate functions are selected. The PS/2 inputs under this condition are seen as a high to the PS/2 device interface logic. Whenever a PS/2 channel is not enabled, the input signals to that channel must be high. The FDC37N958FR provides this through the use of weak pull-ups since the EM and KB channels share a common receive path and the IM and PS2 channels also share a common receive path.
GPIO20_DIR MISC1 PS2_CLK_OUT GPIO20_OUT 1 PIN 52 0
GPIO20_IN PS2_CLK_IN 8051_RX
FIGURE 24 - GPIO[20] ALTERNATE FUNCTION STRUCTURE
SMSC DS - FDC37N958FR
Page 204
Rev. 09/01/99
GPIO21_DIR MISC1 MISC3 8051_TX GPIO21_OUT PS2_DAT_OUT GPIO21_IN PS2_DAT_IN
FIGURE 25 - GPIO21 ALTERNATE FUNCTION STRUCTURE
1 0 0 PIN 53 1
PIN IRTX IRRX
MISC2 = 0 (DEFAULT) from IrCC Block from IrCC Block
MISC2 = 1 from IR Data Register from IR Data Register MISC4 = 1 PWM0 PWM1
PIN PWM0/OUT10 PWM1/OUT11 PIN OUT5 OUT6 PIN GPIO[ 17] PIN GPIO[8] GPIO[9]
MISC4 = 0 (DEFAULT) OUT10 OUT11
MISC5 = 0 (DEFAULT) OUT5 OUT6 MISC6 = 0 (DEFAULT) GPIO[17]
MISC5 = 1 nDS1 nMTR1 MISC6 = 1 GateA20
MISC7 = 0 (DEFAULT) GPIO[8] GPIO[9]
MISC7 = 1 IrCC Block COM-RX Port IrCC Block COM-TX Port
MULTIPLEXING_2 REGISTER Host N/A 8051 0x7F40 Power VCC1 Default 0x00
SMSC DS - FDC37N958FR
Page 205
Rev. 09/01/99
8051 R/W Bit Def
D7 R/W MISC 16
D6 R/W MISC 15
D5 R/W MISC 14
D4 R/W MISC 13 PIN GPIO[4] GPIO[4] KSO14
D3 R/W MISC 12
D2 R/W MISC 11
D1 R/W MISC 10
D0 R/W MISC 9
MISC9 0 (default) 1
GPIO[5] GPIO[5] KSO15
PIN OUT[8] PIN KSO12 MISC17 MISC10 MISC6 (PIN 202) (PIN 23) 0 0 0 OUT8 KSO12 0 0 1 CPU_RESET KSO12 0 1 X DRQ2 KSO12 1 0 0 OUT8 OUT8 1 0 1 CPU_RESET CPU_RESET 1 1 0 DRQ2 OUT8 1 1 1 DRQ2 CPU_RESET With this definition, only the pair [OUT8 & CPU_RESET] can not simultaneously exist on pins 202 and 23.
SMSC DS - FDC37N958FR
Page 206
Rev. 09/01/99
M ISC10 M ISC6 CPU_RESET OUT8 DRQ2 1 0 0 1 PIN 202
1 KSO12 M ISC17 0
PIN 23
FIGURE 26 - PINS 202 AND 23 ALTERNATE FUNCTION OPERATION MISC17 PIN GPIO18 (PIN 207) PIN KSO13 (PIN 22) 0 GPIO18 + nDACK2 (1) KSO13 1 nDACK2 GPIO18 Note 1: nDACK2 can be received on in 207 when MISC17 = 0 by setting GPIO18's DIR bit to 0.
G P IO 1 8 _ D IR
G P IO 1 8 _ O U T
P IN 2 0 7
nDACK2
0 G P IO 1 8 _ IN 1 M IS C 1 7 1 KSO 13 0 P IN 2 2
[ (M IS C 1 7 = 0 ) | (G P IO 1 8 _ D IR & M IS C 1 7 = 1 ) ]
FIGURE 27 - PIN 207 AND 22 ALTERNATE FUNCTION OPERATION MISC11 0 (default) 1 PIN OUT[9] OUT[9] DRQ3 PIN GPIO[19] GPIO[19] nDACK3
SMSC DS - FDC37N958FR
Page 207
Rev. 09/01/99
PIN GPIO[11] GPIO[12] GPIO[13] GPIO[14] GPIO[15]
MISC12 = 0 (DEFAULT) GPIO[11] GPIO[12] GPIO[13] GPIO[14] GPIO[15]
MISC12 = 1 nCTS2 nDTR2 nDSR2 nDCD2 nRI2
MISC[14:13] = 0 (DEFAULT) [0:0] (default) [0:1] [1:0] [1:1] MISC[16:15] = 0 (DEFAULT) [0:0] (default) [0:1] [1:0] [1:1]
PIN GPIO[6] GPIO[6] IR_MODE (IrCC GP Data) output FRX input Reserved PIN GPIO[10] GPIO[10] IR_MODE (IrCC GP Data) output FRX input nRTS2
MULTIPLEXING_3 REGISTER Host N/A 8051 0x7F30 Power VCC1 Default 0x00 D7 - D2 D1 D0 8051 R/W R R/W R/W Bit Def. Reserved 0 MISC17 MISC8 Note : Originally Bit 7 in the Output Enable Register was defined as MISC8, but this bit is now Reserved. MISC8 0 (default) 1 PIN GPIO[16] GPIO[16] MID1
MISC17 is described in the Multiplexing_2 register section.
SMSC DS - FDC37N958FR
Page 208
Rev. 09/01/99
REAL TIME CLOCK
GENERAL DESCRIPTION A[0:7] The Real Time Clock Supercell (RTC) is a complete time of day clock with alarm and one hundred year calendar, a programmable periodic interrupt, and a programmable square wave generator. Features ! ! ! ! Counts seconds, minutes, and hours of the day. Counts days of the week, date, month and year. Binary or BCD representation of time, calendar and alarm. 24 hour daily alarm. Low active block select - This input is low during any CPU cycle in which the RTC is to be accessed. (Active for addresses 70H, 71H and 74H, 76H). nIOR CPU output data strobe - This port is a low whenever the CPU reads data from an internal RTC register. The nIOR low condition causes the contents of the addressed register to output its data onto the data bus. nIOW CPU write data strobe - The low to high transition of this port latches the contents of the data bus into the selected RTC register. The 8 address lines which select which internal register is to be accessed by any CPU operation. nCS
Port Definition and Description OSC Clock input pin - Maximum clock frequency is 32.768 KHz. DB[0:7] IN CPU data bus - All communication of data and control between the RTC DB[0-7] OUT and the CPU are carried out over this data bus.
SMSC DS - FDC37N958FR
Page 209
Rev. 09/01/99
ISA I/O Interface Table 64 Table 65 - RTC ISA I/O Address Map ISA ADDRESS FUNCTION (NOTE 1) Base (R/W) Address Register (70H/74H) Data Register (71H/76H)
Base+1 (R/W)
All addresses are qualified by AEN. Note 1: The RTC can be enabled or disabled through the configuration registers. RTC Address Register Writing to this register, sets the CMOS address that will be read or written. Port 70H (with RTC data register at 71H) addresses the first 128 CMOS bytes and port 74H (with RTC Data register at 76H) is for the next 128 CMOS bytes. Bit D7 is not used for the CMOS RAM address decoding (all eight bits are read/write). RTC Data Register A read of this register will read the contents of the selected CMOS register. A write to this register will write to the selected CMOS register (71H or 76H).
SMSC DS - FDC37N958FR
Page 210
Rev. 09/01/99
VCC1 POR The VCC1 POR pin does not affect the clock calendar, or RAM functions. When VCC1 POR is active the following occurs: 1. 2. 3. 4. 5. 6. 7. 8. 9. Periodic Interrupt Enable (PIE) is cleared to "0". Alarm Interrupt Enable (AIE) bit is cleared to "0". Update Ended Interrupt Enable (UIE) bit is cleared to "0". Update Ended Interrupt Flag (UF) bit is cleared to "0". Interrupt Request status Flag (IRQF) bit is cleared to "0". Periodic Interrupt Flag (PIF) is cleared to "0". The RTC and CMOS registers are not accessable. Alarm Interrupt Flag (AF) is cleared to "0". nIRQ pin is in high impedance state.
8051D The 8051 Disable pin, when active, prevents 8051 access to the clock calendar, or RAM functions (refer to the Power Management section). PS The power-sense pin is used in the control of the Valid RAM and Time (VRT) bit in Register D. When the PS pin is low, the VRT bit is cleared to "0". As power is applied, the VRT bit remains low indicating that the contents of the RAM, time registers and calendar are not guaranteed. PS must go high after powerup to allow the VRT bit to be set by a read of Register D. This is an internal signal used to detect if both the main power and the battery power are both low at the same time. This is the only case where the contents of the RAM, time registers and calendar are not valid. nIRQ The nIRQ pin is an active low output. output remains low as long as the causing the interrupt is present corresponding interrupt-enable bit Reading register C or the VCC1 POR the nIRQ pin. The nIRQ status bit and the is set. pin clears
HOSTD The Host Disable pin, when active, prevents host access to the clock calendar, or RAM functions (refer to the Power Management section).
SMSC DS - FDC37N958FR
Page 211
Rev. 09/01/99
Internal Registers Table 66 shows the address map of the RTC, ten bytes of time, calendar, and alarm data, four control and status bytes, 241 bytes of CMOS registers and one RTC control register.
ADDRESS 0 1 2 3 4 5 6 7 8 9 A B C D E-7F (B2) 0-7E (B2) FF
Table 66 - Address Map REGISTER TYPE REGISTER FUNCTION R/W Register 0: Seconds R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R R R/W R/W R/W Register 1: Seconds Alarm Register 2: Minutes Register 3: Minutes Alarm Register 4: Hours Register 5: Hours Alarm Register 6: Day of Week Register 7: Date of Month Register 8: Month Register 9: Year Register A: Register B: (Bit 0 is Read Only) Register C: Register D: General purpose Bank 2: General purpose Bank 2: Shared RTC Control
All 14 bytes are directly writable and readable by the host with the following exceptions: A. B. C. D. Registers C and D are read only Bit 7 of Register A is read only Bits 0 of Register B is read only Bits 7-1 of the Shared RTC Control register are read only
SMSC DS - FDC37N958FR
Page 212
Rev. 09/01/99
Time Calendar and Alarm The processor program obtains time and calendar information by reading the appropriate locations. The program may initialize the time, calendar and alarm by writing to these locations. The contents of the 10 time, calendar and alarm bytes can be in binary or BCD as shown in Table 67. Before initializing the internal registers, the SET bit in Register B should be set to a "1" to prevent time/calendar updates from occurring. The program initializes the 10 locations in the binary or BCD format as defined by the DM bit in Register B. The SET bit may then be cleared to allow updates. The 12/24 bit in Register B establishes whether the hour locations represent 1 to 12 or 0 to 23. The 12/24 bit cannot be changed without reinitializing the hour locations. When the 12 hour format is selected, the high order bit of the hours byte represents PM when it is a "1".
Once per second, the 10 time, calendar and alarm bytes are switched to the update logic to be advanced by one second and to check for an alarm condition. If any of the 10 bytes are read at this time, the data outputs are undefined. The update cycle time is shown in Table 67. The update logic contains circuitry for automatic end-of-month recognition as well as automatic leap year compensation. The three alarm bytes may be used in two ways. First, when the program inserts an alarm time in the appropriate hours, minutes and seconds alarm locations, the alarm interrupt is initiated at the specified time each day if the alarm enable bit is high. The second usage is to insert a "don't care" state in one or more of three alarm bytes. The "don't care" code is any hexadecimal byte from C0 to FF inclusive. That is the two most significant bits of each byte, when set to "1" create a "don't care" situation. An alarm interrupt each hour is created with a "don't care" code in the hours alarm location. Similarly, an alarm is generated every minute with "don't care" codes in the hours and minutes alarm bytes. The "don't care" codes in all three alarm bytes create an interrupt every second.
SMSC DS - FDC37N958FR
Page 213
Rev. 09/01/99
ADD 0 1 2 3 4
Table 67 - RTC Register Valid Range BCD REGISTER FUNCTION RANGE Register 0: Seconds 00-59 Register 1: Seconds Alarm Register 2: Minutes Register 3: Minutes Alarm Register 4: Hours (12 hour mode) (24 hour mode) 00-59 00-59 00-59 01-12 am 81-92 pm 00-23 01-12 am 81-92 pm 00-23 01-07 01-31 01-12 00-99
BINARY RANGE 00-3B 00-3B 00-3B 00-3B 01-0C 81-8C 00-17 01-0C 81-8C 00-17 01-07 01-1F 01-0C 00-63
5
Register 5: Hours Alarm (12 hour mode) (24 hour mode)
6 7 8 9
Register 6: Day of Week Register 7: Day of Month Register 8: Month Register 9: Year
Update Cycle
An update cycle is executed once per second if the SET bit in Register B is clear and the DV0-DV2 divider is not clear. The SET bit in the "1" state permits the program to initialize the time and calendar bytes by stopping an existing update and preventing a new one from occurring. The primary function of the update cycle is to increment the seconds byte, check for overflow, increment the minutes byte when appropriate and so forth through to the year of the century byte. The update cycle also compares each
alarm byte with the corresponding time byte and issues an alarm if a match or if a "don't care" code is present. The length of an update cycle is shown in Table 68. During the update cycle the time, calendar and alarm bytes are not accessible by the processor program. If the processor reads these locations before the update cycle is complete the output will be undefined. The UIP (update in progress) status bit is set during the interval. When the UIP bit goes high, the update cycle will begin 244 "s later. Therefore, if a low is read on the UIP bit the user has at least 244 "s before time/calendar data will be changed.
SMSC DS - FDC37N958FR
Page 214
Rev. 09/01/99
Table 68 - RTC Update Cycle Timing INPUT CLOCK FREQUENCY 32.768 KHz 32.768 KHz UPDATE CYCLE TIME 1948 "s MINIMUM TIME BEFORE START OF UPDATE CYCLE 244 "s
UIP BIT 1 0
Control and Status Registers
The RTC has four registers which are accessible to the processor program at all times, even during the update cycle.
Register A (AH) B7 UIP UIP The update in progress bit is a status flag that may be monitored by the program. When UIP is a "1" the update cycle is in progress or will soon begin. When UIP is a "0" the update cycle is not in progress and will not be for at least 244 "s. The time, calendar, and alarm information is fully available to the program when the UIP bit is "0". The UIP bit is a read only bit and is not affected by VCC1 POR. Writing the SET bit in Register B to a "1" inhibits any update cycle and then clears the UIP status bit. B6 DV2 B5 DV1 B4 DV0 B3 RS3 DV2-0 Three bits are used to permit the program to select various conditions of the 22 stage divider chain. Table 68 shows the allowable combinations. The divider selection bits are also used to reset the divider chain. When the time/calendar is first initialized, the program may start the divider chain at the precise time stored in the registers. When the divider reset is removed the first update begins one-half second later. These three read/write bits are not affected by VCC1 POR. B2 RS2 B1 RS1 B0 RS0
SMSC DS - FDC37N958FR
Page 215
Rev. 09/01/99
OSCILLATOR FREQUENCY 32.768 KHz 32.768 KHz 32.768 KHz 32.768 KHz 32.768 KHz
Table 69 - RTC Divider Selection Bits REGISTER A BITS DV2 DV1 DV0 MODE 0 0 0 Oscillator Disabled 0 0 1 Oscillator Disabled 0 1 0 Normal Operate 0 1 1 Test 1 0 X Test 1 1 X Reset Divider or disable the interrupt with the PIE bit in Register B. Table 70 lists the periodic interrupt rates and equivalent output frequencies that may be chosen with the RS0-RS3 bits. These four bits are read/write bits which are not affected by VCC1 POR.
RS3-0 The four rate selection bits select one of 15 taps on the divider chain or disable the divider output. The selected tap determines rate or frequency of the periodic interrupt. The program may enable
Table 70 - RTC Periodic Interrupt Rates RATE SELECT RS3 RS2 RS1 RS0 0000 0001 0010 0011 0100 0101 0110 0 1 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 1 0 0 1 1 0 0 1 1 1 0 1 0 1 0 1 0 1 32.768 KHZ TIME BASE PERIOD RATE OF INTERRUPT 0.0 3.90625 ms 7.8125 ms 122.070 "s 244.141 "s 488.281 "s 976.562 "s 1.953125 ms 3.90625 ms 7.8125 ms 15.625 ms 31.25 ms 62.5 ms 125 ms 250 ms 500 ms FREQUENCY OF INTERRUPT 256 KHz 128 Hz 8.192 Hz 4.096 KHz 2.048 KHz 1.024 KHz 512 Hz 256 Hz 128 Hz 64 Hz 32 Hz 16 Hz 8 Hz 4 Hz 2 Hz
SMSC DS - FDC37N958FR
Page 216
Rev. 09/01/99
REGISTER B (BH) B7 SET SET UIE When the SET bit is a "0", the update functions normally by advancing the counts once-per-second. When the SET bit is a "1", an update cycle in progress is aborted and the program may initialize the time and calendar bytes without an update occurring in the middle of initialization. SET is a read/write bit which is not modified by VCC1 POR or any internal functions. PIE DM The periodic interrupt enable bit is a read/write bit which allows the periodic-interrupt flag (PF) bit in Register C to cause the IRQB port to be driven low. The program writes a "1" to the PIE bit in order to receive periodic interrupts at the rate specified by the RS3 - RS0 bits in Register A. A "0" in PIE blocks IRQB from being initiated by a periodic interrupt, but the periodic flag (PF) is still set at the periodic rate. PIE is not modified by any internal function, but is cleared to "0" by a VCC1 POR. AIE The alarm interrupt enable bit is a read/write bit, which when set to a "1" permits the alarm flag (AF) bit in Register C to assert IRQB. An alarm interrupt occurs for each second that the three time bytes equal the three alarm bytes (including a "don't care" alarm code of binary 11XXXXXX). When the AIE bit is a "0", the AF bit does not initiate an IRQB signal. The VCC1 POR port clears AIE to "0". The AIE bit is not affected by any internal functions. The data mode bit indicates whether time and calendar updates are to use binary or BCD formats. The DM bit is written by the processor program and may be read by the program, but is not modified by any internal functions or by VCC1 POR. A "1" in DM signifies binary data, while a "0" in DM specifies BCD data. 24/12 The 24/12 control bit establishes the format of the hours byte as either the 24 hour mode if set to a "1", or the 12 hour mode if cleared to a "0". This is a read/write bit which is not affected by VCC1 POR or any internal function. DSE The daylight savings enable bit is read only and is always set to a "0" to indicate that the daylight savings time option is not available. The update-ended interrupt enable bit is a read/write bit which enables the update-end flag (UF) bit in Register C to assert IRQB. The VCC1 POR port or the SET bit going high clears the UIE bit. RES Reserved - read as zero B6 PIE B5 AIE B4 UIE B3 RES B2 DM B1 24/12 B0 DSE
SMSC DS - FDC37N958FR
Page 217
Rev. 09/01/99
REGISTER C (CH) - READ ONLY REGISTER B7 IRQF IRQF AF The interrupt request flag is set to a "1" when one or more of the following are true: PF = PIE = 1 AF = AIE = 1 UF = UIE = 1 Any time the IRQF bit is a "1", the IRQB signal is driven low. All flag bits are cleared after Register C is read or by the VCC1 POR port. PF The periodic interrupt flag is a read only bit which is set to a "1" when a particular edge is detected on the selected tap of the divider chain. The RS3 -RS0 bits establish the periodic rate. PF is set to a "1" independent of the state of the PIE bit. PF being a "1" sets the IRQF bit and initiates an IRQB signal when PIE is also a "1". The PF bit is cleared by VCC1 POR or by a read of Register C . The alarm interrupt flag when set to a "1" indicates that the current time has matched the alarm time. A "1" in AF causes a "1"to appear in IRQF and the IRQB port to go low when the AIE bit is also a "1". A VCC1 POR or a read of Register C clears the AF bit. UF The update-ended interrupt flag bit is set after each update cycle. When the UIE bit is also a "1", the "1" in UF causes the IRQF bit to be set and asserts IRQB. A VCC1 POR or a read of Register C causes UF to be cleared. b3-0 The unused bits of Register C are read as "0" and cannot be written. B6 PF B5 AF B4 UF B3 0 B2 0 B1 0 B0 0
SMSC DS - FDC37N958FR
Page 218
Rev. 09/01/99
REGISTER D (DH) READ ONLY REGISTER B7 VRT VRT Register EH-FEH: General Purpose When a "1", this bit indicates that the contents of the RTC are valid. A "0" appears in the VRT bit when the battery voltage is low. The VRT bit is a read only bit which can only be set by a read of Register D. Refer to Power Management for the conditions when this bit is reset. The processor program can set the VRT bit when the time and calendar are initialized to indicate that the time is valid. b6 - b0 The remaining bits of Register D are read as zeros and cannot be written. The FDC37N958FR implements an interface that allows the 8051 to read/write the RTC and CMOS registers. Refer to the Keyboard Controller Section for the definition of these registers. Registers Eh-FEH are general purpose "CMOS" registers. These registers can be used by the host or 8051 and are fully available during the time update cycle. The contents of these registers are preserved by VCC0 power. Registers Eh-7Eh are in bank one and registers 80h-FEh are in bank 2. Register 7FH, FFH: Shared RTC Control B6 0 B5 0 B4 0 B3 0 B2 0 B1 0 B0 0
SMSC DS - FDC37N958FR
Page 219
Rev. 09/01/99
Interrupts
The RTC includes three separate fully-automatic sources of interrupts to the processor. The alarm interrupt may be programmed to occur at rates from one-per-second to one-a-day. The periodic interrupt may be selected for rates from half-a-second to 122.070 "s. The update ended interrupt may be used to indicate to the program that an update cycle is completed. Each of these independent interrupts are described in greater detail in other sections. The processor program selects which interrupts, if any, it wishes to receive by writing a "1" to the appropriate enable bits in Register B. A "0" in an enable bit prohibits the IRQB port from being asserted due to that interrupt cause. When an interrupt event occurs a flag bit is set to a "1" in Register C. Each of the three interrupt sources have separate flag bits in Register C, which are set independent of the state of the corresponding enable bits in Register B. The flag bits may be used with or without enabling the corresponding enable bits. The flag bits in Register C are cleared (record of the interrupt event is erased) when Register C is read. Double latching is included in Register C to ensure the bits that are set are stable throughout the read cycle. All bits which are high when read by the program are cleared, and new interrupts are held until after the read cycle. If an interrupt flag is already set
when the interrupt becomes enabled, the IRQB port is immediately activated, though the interrupt initiating the event may have occurred much earlier. When an interrupt flag bit is set and the corresponding interrupt-enable bit is also set, the IRQB port is driven low. IRQB is asserted as long as at least one of the three interrupt sources has its flag and enable bits both set. The IRQF bit in Register C is a "1" whenever the IRQB port is being driven low. Frequency Divider The RTC has 22 binary divider stages following the clock input. The output of the divider is a 1 MHz signal to the update-cycle logic. The divider is controlled by the three divider bits (DV3-DV0) in Register A. As shown in Table 69 the divider control bits can select the operating mode, or be used to hold the divider chain reset which allows precision setting of the time. When the divider chain is changed from reset to the operating mode, the first update cycle is one-half second later. Periodic Interrupt Selection The periodic interrupt allows the IRQB port to be triggered from once every 500 ms to once every 122.07 "s. As Table 70 shows, the periodic interrupt is selected with the RS0-RS3 bits in Register A. The periodic interrupt is enabled with the PIE bit in Register B.
SMSC DS - FDC37N958FR
Page 220
Rev. 09/01/99
Power Management
The HOSTD signal controls all host bus inputs to the RTC and RAM (nIOW, nIOR, VCC1 POR). When asserted, it disallows any modification of the RTC and RAM data by the host. HOSTD is asserted whenever: 1. 2. Vcc2 is below 4.0 volts nominal PowerGood is inactive and Vcc2 is above 4.0 volts nominal
When the Vcc2 voltage drops below 4.0 volts nominal, all host inputs are locked out so that the internal registers cannot be modified by the host system. This lockout condition continues for 500usec (min) to 1msec (max) after the VCC2 power has been restored. The timed lockout does not occur under the following conditions: 1. 2. The Divider Chain Controls (bits 6-4) are in any mode but Normal Operation ("010"). The VRT bit is a "0".
The 8051D signal controls all 8051 inputs to the RTC and RAM. When asserted, it disallows any modification of the RTC and RAM data by the 8051. 8051D is asserted whenever: 1. 2. Vcc1 is below 2.5 volts nominal. Vcc1 is above 2.5 volts and the 8051 is in its hardware initialization routine.
To minimize power consumption, the oscillator is not operational under the following conditions: 1. 2. The Divider Chain Controls (bits 6-4) are in Oscillator Disabled mode (000, or 001). If VCC1=0 and the VCC0 is removed and the re-applied (a new battery is installed) the following occurs: a) The oscillator is disabled immediately. b) Initialize all registers 00-0D to a "00" when VCC1 is applied.
The RTC (and CMOS) always draws power from VCC0. Note: There are three power supplies in the system VCC0, VCC1 and VCC2. VCC0 must be present before or at the same time as VCC1. VCC2 (NOMINAL) <4.0 <4.0 to >4.0 >4.0 >4.0 >4.0 POWER GOOD x 0 0->1 0 1
VCC1 must be present before or at the same time as VCC2. The RTC and CMOS registers always draw power from VCC0. HOST REGISTER ACCESS N N Timed Lockout (Note 1) N Y
BATTERY VOLTAGE >2.5V Y Y Y Y Y
Note 1: If VCC2 and VCC1 are powered up at the same time, then the Host Register Access is delayed by the timed lockout and the 8051 Initialization, whichever is longer. VCC1 (NOMINAL) <2.5 <2.5 to >2.5 >2.5 >2.5 VCC2 (NOMINAL) x x x x 8051 INITIALIZATION x In Init In Init Init Finished 8051 REGISTER ACCESS N N N Y
SMSC DS - FDC37N958FR
Page 221
Rev. 09/01/99
ACCESS.bus
Background The FDC37N958FR supports ACCESS.bus. ACCESS.bus is a serial communication protocol between a computer host and its peripheral devices. It provides a simple, uniform and inexpensive way to connect peripheral devices to a single computer port. A single ACCESS.bus on a host can accommodate up to 125 peripheral devices. The ACCESS.bus protocol includes a physical 2 TM layer based on the I C serial bus developed
by Philips, and several software layers. The software layers include the base protocol, the device driver interface, and several specific device protocols. For a description of the ACCESS.bus protocol, please refer to the ACCESS.bus Specifications Version 2.2, February 1994, available from the ACCESS.bus Industry Group (ABIG). The ACCESS.bus interface is based on the PCF8584 controller. The registers are mapped into the 8051's external memory mapped register space. The addresses for the registers are shown in Table 71.
Table 71 - ACCESS.bus Register Addresses ADDRESS (NOTE 1) ACCESS RIGHTS REGISTER 7F31h W Control 7F31h R Status 7F32h R/W Own Address 7F33h R/W Data (1) 7F34h R/W Clock Note: These Registers are only directly accessible by the 8051 and reside within the Memory Mapped Data address space. Note 1: Bits 2 through 6 are read only reserved.
S1 S1 S0' S0 S2 8051's external
SMSC DS - FDC37N958FR
Page 222
Rev. 09/01/99
Register Description
The ACCESS.bus interface has four internal register locations. Two of these, Own Address register S0' and Clock register S2, are used for initialization of the chip. Normally they are only written once directly after resetting of the chip. The other two registers, the Data register S0, and the Control/Status register S1, (which functions as a double register) are used during actual data transmission/reception. Register s0 performs all serial-to-parallel interfacing with the ACCESS.bus. Register S1 contains
ACCESS.bus status information required for bus access and/or monitoring. ACCESS.bus CONTROL/STATUS REGISTER S1 The control/status register controls the ACCESS.bus operation and provides status information. This register has separate read and write functions for all bit positions. The writeonly section provides register access control and control over ACCESS.bus signals, while the read-only section provides ACCESS.bus status information.
CONTROL R/W Bit Def Status R/W Bit Def
D7 W PIN D7 R PIN
ACCESS.bus Control/Status Register S1: D6 D5 D4 D3 W W W W ES0 Reserved Reserved ENI D6 D5 D4 D3 R R R R 0 STS BER LRB
D2 W STA D2 R AAS
D1 W STO D1 R LAB
D0 W ACK D0 R nBB
Bit Definitions Register S1 Control Section The write-only section of S1 enables access to registers S0, S1 and S2, and also controls ACCESS.bus operation. BIT 7 PIN
communication with serial shift register S0 is enabled and the S1 bus status bits are made available for reading. With ESO = 0, bits ENI, STA, STO and ACK of S1 can be read for test purposes. BIT 5 and 4 Reserved BIT 3 ENI
Pending Interrupt Not. Writing the PIN bit to a logic "1" deasserts all status bits except for the nBB (Bus Busy) - nBB is not affected. The PIN bit is a self-clearing bit. Writing this bit to a logic "0" has no effect. This may serve as a software reset function. BIT 6 ESO Enable Serial Output. ESO enables or disables the serial ACCESS.bus I/O. When ESO is high, ACCESS.bus communication is enabled;
This bit enables the internal interrupt, nINT, which is generated when the PIN bit is active (logic 0). BIT 2 and 1 STA and STO These bits control the generation of the ACCESS.bus Start condition and transmission of slave address and R/nW bit, generation of repeated Start condition, and generation of the STOP condition (see Table 72).
SMSC DS - FDC37N958FR
Page 223
Rev. 09/01/99
Table 72 - Instruction Table for Serial Bus Control PRESENT MODE FUNCTION OPERATION SLV/REC START Transmit START+address, remain MST/TRM if R/nW=0; go to MST/REC if R/nW=1. 1 0 MST/TRM REPEAT START Same as for SLV/REC 0 1 MST/REC; STOP READ; Transmit STOP go to SLV/REC mode; MST/TRM STOP WRITE Note 1 1 1 MST DATA Send STOP, START and address after CHAINING last master frame without STOP sent; Note 2 0 0 ANY NOP No operation; Note 3 Note 1: In master receiver mode, the last byte must be terminated with ACK bit high (`negative acknowledge'). Note 2: If both STA and STO are set high simultaneously in master mode, a STOP condition followed by a START condition + address will be generated. This allows `chaining' of transmissions without relinquishing bus control. Note 3: All other STA and STO mode combinations not mentioned in Table 71 are NOPs. STA 1 STO 0
SMSC DS - FDC37N958FR
Page 224
Rev. 09/01/99
BIT 0 ACK This bit must be set normally to logic "1". This causes the ACCESS.bus to send an acknowledge automatically after each byte (this occurs during the 9th clock pulse). The bit must be reset (to logic "0") when the ACCESS.bus controller is operating in master/receiver mode and requires no further data to be sent from the slave transmitter. This causes a negative acknowledge on the ACCESS.bus, which halts further transmission from the slave device. Register S1 Status Section The read-only section of S1 enables access to ACCESS.bus status information. BIT 7 PIN Pending Interrupt Not. This bit is a status flag which is used to synchronize serial communication and is set to logic "0" whenever the chip requires servicing. The PIN bit is normally read in polled applications to determine when an ACCESS.bus byte transmission/reception is completed. When acting as transmitter, PIN is set to logic "1" (inactive) each time S0 is written. In receiver mode, the PIN bit is automatically set to logic "1" each time the data register S0 is read. After transmission or reception of one byte on the ACCESS.bus (nine clock pulses, including acknowledge) the PIN bit will be automatically reset to logic "0" (active) indicating a complete byte transmission/reception. When the PIN bit is subsequently set to logic "1" (inactive) all status bits will be reset to "0" on a BER (bus error) condition. In polled applications, the PIN bit is tested to determine when a serial transmission/reception
has been completed. When the ENI bit (bit 4 of write-only section of register S1) is also set to logic "1" the hardware interrupt is enabled. In this case, the PI flag also triggers and internal interrupt (active low) via the nINT output each time PIN is reset to logic "0". When acting as a slave transmitter or slave receiver, while PIN = "0", the chip will suspend ACCESS.bus transmission by holding the SCL line low until the PIN bit is set to logic "1" (inactive). This prevents further data from being transmitted or received until the current data byte in S0 has been read (when acting as slave receiver) or the next data byte is written to S0 (when acting as slave transmitter). PIN Bit Summary ! The PIN bit can be used in polled applications to test when a serial transmission has been completed. When the ENI bit is also set, the PIN flag sets the internal interrupt via the nINT output. ! In transmitter mode, after successful transmission of one byte on the ACCESS.bus the PIN bit will be automatically reset to logic "0" (active) indicating a complete byte transmission. ! In transmitter mode, PIN is set to logic "1" (inactive) each time register S0 is written. ! In receiver mode, PIN is set to logic "0" (inactive) on completion of each received byte. Subsequently, the SCL line will be held low until PIN is set to logic "1". ! In receiver mode, when register S0 is read, PIN is set to logic "1" (inactive). ! In slave receiver mode, an ACCESS.bus STOP condition will set PIN=0 (active). ! PIN=0 if a bus error (BER) occurs. BIT 6 Reserved, Logic 0.
SMSC DS - FDC37N958FR
Page 225
Rev. 09/01/99
BIT 5 STS When in slave receiver mode, this flag is asserted when an externally generated STOP condition is detected (used only in slave receiver mode). BIT 4 BER Bus error; a misplaced START or STOP condition has been detected. Resets nBB (to logic "1"; inactive), sets PIN = "0" (active). BIT 3 LRB/AD0 Last Received Bit or Address 0 (general call) bit. This status bit serves a dual function, and is valid only while PIN=0: 1. LRB holds the value of the last received bit over the ACCESS.bus while AAS=0 (not addressed as slave). Normally this will be the value of the slave acknowledgment; thus checking for slave acknowledgment is done via testing of the LRB. 2. ADO; when AAS = "1" (Addressed as slave condition) the ACCESS.bus controller has been addressed as a slave. Under this condition, this bit becomes the AD0 bit and will be set to logic "1" if the slave address received was the `general call' (00h) address, or logic "0" if it was the ACCESS.bus controller's own slave address. BIT 2 AAS Addressed As Slave bit. Valid only when PIN=0. When acting as slave receiver, this flag is set when an incoming address over the
ACCESS.bus matches the value in own address register S0' (shifted by one bit) or if the ACCESS.bus `general call' address (00h) has been received (`general call' is indicated when AD0 status bit is also set to logic "1"). BIT 1 LAB Lost Arbitration Bit. This bit is set when, in multimaster operation, arbitration is lost to another master on the ACCESS.bus. BIT 0 nBB Bus Busy bit. This is a read-only flag indicating when the ACCESS.bus is in use. A zero indicates that the bus is busy, and access is not possible. This bit is set/reset (logic "1"/logic "0") by Start/Stop conditions. OWN ADDRESS REGISTER S0' When the chip is addressed as slave, this register must be loaded with the 7-bit ACCESS.bus address to which the chip is to respond. During initialization, the own address register S0' must be written to, regardless whether it is later used. The Addressed As Slave (AAS) bit in status register S1 is set when this address is received (the value in S0 is compared with the value in S0'). Note that the S0 and S0' registers are offset by one bit; hence, programming the own address register S0' with a value of 55h will result in the value AAh being recognized as the chip's ACCESS.bus slave address. After reset, S0' has default address 00h.
SMSC DS - FDC37N958FR
Page 226
Rev. 09/01/99
ACCESS.bus Own Address Register S0' OWN ADDR R/W Bit Def D7 R/W Reserved D6 R/W Slave Address 6 D5 R/W Slave Address 5 D4 R/W Slave Address 4 D3 R/W Slave Address 3 D2 R/W Slave Address 2 D1 R/W Slave Address 1 D0 R/W Slave Address 0
DATA SHIFT REGISTER S0 Register S0 acts as serial shift register and read buffer interfacing to the ACCESS.bus. All read and write operations to/from the ACCESS.bus are done via this register. ACCESS.bus data is always shifted in or out of shift register S0.
In receiver mode the ACCESS.bus data is shifted into the shift register until the acknowledge phase. Further reception of data is inhibited (SCL held low) until the S0 data shift register is read. In the transmitter mode data is transmitted to the ACCESS.bus as soon as it is written to the S0 shift register if the serial I/O is enabled (ESO=1).
DATA R/W CLOCK REGISTER S2
D7 R/W
ACCESS.bus Data Register D6 D5 D4 D3 D2 R/W R/W R/W R/W R/W
D1 R/W
D0 R/W
Register S2 controls the selection of the internal chip clock frequency used for the ACCESS.bus
block. This determines the SCL clock frequency generated by the chip. The selection is made via Bits[2:0] (see Table 73).
SMSC DS - FDC37N958FR
Page 227
Rev. 09/01/99
ACCESS.bus Clock Register D6-D2 D1 D0 8051 R/W R R/W R/W Reserved 00 - clock off (default) 01 - 32 KHz clock 10 - 8051 clock 11 - 24 MHz clock (see table below) Note 1: ACCESS.bus Reset, not self-clearing, must be written high and then written low. Bit 7 AB_RST: (ACCESS.bus Reset) setting this bit re-initializes all logic and registers in the ACCESS.bus block. D7 R/W AB_RST (Note 1) Table 73 - Internal Clock Rates and ACCESS.bus Data Rates DATA NOMINAL NOMINAL CLOCK RATE RATE HIGH LOW Off Ring Osc f/240 96/f Ring Osc=4 MHz 16.7 KHz 24"s Ring Osc=6 MHz 25 KHz 16"s Ring Osc=8 MHz 33.3 KHz 12"s 12MHz 50 KHz 8"s 14.3 MHz 60 KHz 6.7"s 16 MHz 67 KHz 6"s 24 MHz 100 KHz 4"s f = frequency of the ring oscillator.
ACCESS BUS CLOCK D[1-0] 00 10
MINIMUM HIGH
10 10 10 11
144/f 36"s 24"s 18"s 12"s 10.1"s 9"s 6"s
18/f 4.5"s 3"s 2.25"s 4"s 4"s 4"s 4"s
SMSC DS - FDC37N958FR
Page 228
Rev. 09/01/99
PS/2 Device Interface PS/2 Logic Overview The FDC37N958FR has four PS/2 serial ports implemented in hardware which are directly controlled by the on chip 8051. The hardware implementation eliminates the need to bit bang I/O ports to generate PS/2 ports. The PS/2 logic allows the host to communicate to any serial auxiliary devices compatible with the PS/2 interface through any one of four ports : EM, KB, IM and PS2. There are two identical PS/2 channels, each containing a set of five operating registers. Channel 1 (PS/2 Port 1) consists of ports EM and KB and channel 2 (PS/2 Port 2) consists of ports IM and PS2. Each of the four PS/2 serial ports use a synchronous serial protocol to communicate with the auxiliary device. Each PS/2 port has two signal lines : Clock and Data. Both signal lines are bi-directional and imply open drain outputs. A pull-up resistor (typically 3.3K) is connected to the clock and data lines. This allows either the FDC37N958FR PS/2 logic or the auxiliary device to control both lines. Regardless, the auxiliary device provides the clock for transmit and receive operations. The serial packet is made up of eleven bits, listed in order as they will appear on the data line : start bit, eight data bits (least significant bit first), odd parity, and stop bit. Each bit cell is from 60"S to 100"S long. The data is latched on the high to low transition of the clock.
Transmitting to the Remote Auxiliary Device The PS/2 serial protocol requires that the auxiliary device respond to all transmissions that it receives. The response will either be an 0XFA or 0xEE. The response is stored in the PS/2 ports Receive register. Thus, after each transmission the Receive register should contain either 0xFA or 0xEE. Note: Refer to Application Note 6.19 for programmers details. Receiving from the Remote Auxiliary Device A port is set to receive by selecting the port and enabling the receiver. This is done by writing to the CONTROL register. The PS/2 logic floats the PS/2 port's clock and data line when the port is selected to receive. The auxiliary device initiates the transfer by driving the data line low and 12"S later driving the clock low. The FDC37N958FR PS/2 Logic recognizes this as a start bit. The auxiliary device proceeds by transmitting ten more bits to the FDC37N958FR. The PS/2 Logic latches the data on the high to low transition of the clock. After the stop bit, the PS/2 Logic drives the clock line low until the Receive register is read by the 8051. If there is no error in the transfer, the PS/2 logic sets the Ready bit of the Status register, clears the Error bit of Status register, and clears the Error register. If, however, the receive operation does not complete in 2 ms, the Error bit of the Status register is set together with the RECTIMOUT bit of the Error register, and the Ready bit is not set. Note: Refer to Application Note 6.19 for programmers details.
SMSC DS - FDC37N958FR
Page 229
Rev. 09/01/99
PS/2 Emulation Logic Register Operational Description PS2 Port Control Registers D7 R Reserved Reserved D6 R Reserved Reserved D5 R Reserved Reserved D4 R/W EM_EN IM_EN D3 R/W KB_EN PS2_EN D2 R/W Inhibit Inhibit D1 R/W RX_EN RX_EN D0 R/W TX_EN TX_EN
R/W PS/2 Port1 PS/2 Port2
Only one of bits D2-D0 can be set to "1". PS/2 Port1 Control Register Operation EM_EN KB_EN OPERATION STATUS 0 1 Transmission sent to keyboard, echo command received 1 0 Transmission sent to extention mouse, echo command received 1 1 Transmission inhibited, RTS_timeout error, (illegal state) 0 1 Data received from keyboard, transmission initiated by keyboard 1 0 Data received from mouse, transmission initiated by mouse 1 1 Data received from keyboard and mouse, transmissions are initiated by keyboard and mouse and interlaced to PS/2 Port1 receive register X X EM and KB PS/2 interfaces are disabled. Data written to the PS2 Port1 transmit register is not transmitted and no data is received from the external mouse or keyboard
INHIBIT 0 0 0 0 0 0
RX_EN 0 0 0 1 1 1
TX_EN 1 1 1 0 0 0
1
X
X
SMSC DS - FDC37N958FR
Page 230
Rev. 09/01/99
The operation of the PS/2 Port2 control register is similar for the IM and PS/2 devices. PS/2 Port Status Registers D5 D4 D3 R R R EM_busy KB_busy Inhibit done IM_busy PS2_ Inhibit busy done
R/W PS/2 Port1 PS/2 Port2 Error
D7 R
Reserved Reserved
D6 R
Reserved Reserved
D2 R EM_drdy IM_drdy
D1 R KB_drdy PS2_ drdy
D0 R Error Error
This bit is set in the event of a transmit or receive error condition on either the EM or KB PS/2 ports or the IM or PS/2 ports. The cause of the error can be determined by reading the PS/2 Port1 or PS/2 Port2 Status register. KB_drdy
has been received successfully from the PS/2 IM port. This bit is cleared when the data has been read from the PS/2 Port2 Receive register. Inhibit done This bit is set when the Inhibit bit of the Control register is set. KB_busy
This bit is set if If KB_EN is set and a character has been received successfully from the PS/2 KB port. This bit is cleared when the data has been read from the PS/2 Port1 Receive register. EM_drdy This bit is set if If EM_EN is set and a character has been received successfully from the PS/2 EM port. This bit is cleared when the data has been read from the PS/2 Port1 Receive register. PS2_drdy This bit is set if If PS2_EN is set and a character has been received successfully from the PS/2 PS2 port. This bit is cleared when the data has been read from the PS/2 Port2 Receive register. IM_drdy This bit is set if If IM_EN is set and a character
This bit is set when the PS/2 KB port is actively receiving a character. EM_busy This bit is set when the PS/2 EM port is actively receiving a character. PS2_busy This bit is set when the PS/2 port is actively receiving a character. IM_busy This bit is set when the PS/2 IM port is actively receiving a character. Note: On receive the BUSY bit is set while receiving the first data bit and cleared while receiving the parity bit. On transmit, the BUSY bit is not set at all.
SMSC DS - FDC37N958FR
Page 231
Rev. 09/01/99
R/W Bit Def
D7-D5 R Reserved
D4 R Parity
PS/2 Port Error Status Register 1 and 2 D3 D2 D1 R R R RES_timeout REC_timeout RTS_timeout REC_timeout
D0 R XMT_timeout
XMT_timeout (Transmit_timeout) is set when the device fails to clock out a command within 2 ms of clocking out the start bit. RTS_timeout (ReadyToSend_timeout) is set when the device fails to start clocking out the command within 15 ms.
(RECeiver_timeout) is set when the device does not finish sending a byte within 2 ms of sending the start bit. RES_timeout (RESponse_timeout) is set when the response to a command is not received within 32 ms. Parity The PS/2 ports use odd parity, in the event of a receive parity error this bit is set.
R/W
PS/2 Port Transmit Regsiter 1 and 2 D7 D6 D5 D4 D3 D2 D1 W W W W W W W
D0 W
Data written to the PS/2 Port1/Port2 Transmit register is immediately transmitted onto the enabled PS/2 Port 1/[Port2] port provided that
the PS/2 Port1/[Port2] Inhibit bit is not set and that both PS/2 Port1/[Port2] devices are not enabled for transmit at the same time.
R
D7 R
PS/2 Port Receive Register 1 and 2 D6 D5 D4 D3 D2 D1 R R R R R R
D0 R
If KB_EN, and/or EM_EN is set and PS/2 Port1 RX_EN is set any successfully received characters over the KB and/or the EM PS/2 Port are placed into this register and the EM_drdy or KB_drdy PS/2 Port1 status bit is
set. Similarly, if PS2_EN and/or IM_EN is set and PS/2 Port2 RX_EN is set any successfully received characters over the PS2 and/or IM PS2 Ports are placed into this register and the PS2_drdy or IM_drdy PS/2 Port2 status bit is set.
SMSC DS - FDC37N958FR
Page 232
Rev. 09/01/99
SERIAL INTERRUPTS MSIO will support the serial interrupt scheme, which is adopted by several companies, to transmit interrupt information to the system. The serial interrupt scheme adheres to the Serial IRQ Specification for PCI Systems Version 6.0.
Timing Diagrams For IRQSER Cycle PCICLK = 33 MHz_IN pin IRQSER = SIRQ pin A) Start Frame timing with source sampled a low pulse on IRQ1
SL
or
START FRAME H R T
IRQ0 FRAME S R T
IRQ1 FRAME S R T
IRQ2 FRAME S R T
H PCICLK IRQSER Drive Source
START 1 Host Controller None IRQ1 IRQ1 FIGURE 28 - SERIAL INTERRUPTS WAVEFORM "START FRAME"
SL=Slave Control R=Recovery T=Turn-around
None
H=Host Control
S=Sample
1) Start Frame pulse can be 4-8 clocks wide.
SMSC DS - FDC37N958FR
Page 233
Rev. 09/01/99
B) Stop Frame Timing with Host using 17 IRQSER sampling period
IRQ14 FRAME SRT PCICLK IRQSER Driver None
IRQ15 FRAME SRT
IOCHCK# FRAME SRT
STOP FRAME
NEXT CYCLE T
I
2
H
R
STOP 1 IRQ15 None Host Controller
START3
FIGURE 29 - SERIAL INTERRUPT WAVEFORM "STOP FRAME" H=Host Control 1) 2) 3) R=Recovery T=Turn-around S=Sample I= Idle
Stop pulse is two clocks wide for Quiet mode, three clocks wide for Continuous mode. There may be none, one or more Idle states during the Stop Frame. The next IRQSER cycle's Start Frame pulse may or may not start immediately after the turn-around clock of the Stop Frame.
SMSC DS - FDC37N958FR
Page 234
Rev. 09/01/99
IRQSER Cycle Control There are two modes of operation for the IRQSER Start Frame. Quiet (Active) Mode Any device may initiate a Start Frame by driving the IRQSER low for one clock, while the IRQSER is Idle. After driving low for one clock the IRQSER must immediately be tri-stated without at any time driving high. A Start Frame may not be initiated while the IRQSER is active. The IRQSER is Idle between Stop and Start Frames. The IRQSER is active between Start and Stop Frames. This mode of operation allows the IRQSER to be Idle when there are no IRQ/Data transitions which should be most of the time. Once a Start Frame has been initiated the host controller will take over driving the IRQSER low in the next clock and will continue driving the IRQSER low for a programmable period of three to seven clocks. This makes a total low pulse width of four to eight clocks. Finally, the host controller will drive the IRQSER back high for one clock then tri-state. Any IRQSER Device (i.e., The FDC37C958) which detects any transition on an IRQ/Data line for which it is responsible must initiate a Start Frame in order to update the host controller unless the IRQSER is already in an IRQSER Cycle and the IRQ/Data transition can be delivered in that IRQSER Cycle. Continuous (Idle) Mode Only the Host controller can initiate a Start Frame to update IRQ/Data line information. All other IRQSER agents become passive and may not initiate a Start Frame. IRQSER will be driven low for four to eight clocks by host controller.
This mode has two functions. It can be used to stop or idle the IRQSER or the host controller can operate IRQSER in a continuous mode by initiating a Start Frame at the end of every Stop Frame. An IRQSER mode transition can only occur during the Stop Frame. Upon reset, IRQSER bus is defaulted to continuous mode, therefore only the host controller can initiate the first Start Frame. Slaves must continuously sample the Stop Frames pulse width to determine the next IRQSER Cycle's mode. IRQSER Data Frame Once a Start Frame has been initiated, the FDC37N958FR will watch for the rising edge of the Start Pulse and start counting IRQ/Data Frames from there. Each IRQ/Data Frame is three clocks: Sample phase, Recovery phase, and Turn-around phase. During the sample phase, the FDC37N958FR must drive the IRQSER (SIRQ pin) low, if and only if, its last detected IRQ/Data value was low. If its detected IRQ/Data value is high, IRQSER must be left tristated. During the recovery phase the FDC37N958FR must drive the SERIRQ high, if and only if, it had driven the IRQSER low during the previous sample phase. During the turnaround phase the FDC37N958FR must tri-state the SERIRQ. The FDC37N958FR will drive the IRQSER line low at the appropriate sample point if its associated IRQ/Data line is low, regardless of which device initiated the start frame. The Sample phase for each IRQ/Data follows the low to high transition of the Start Frame pulse by a number of clocks equal to the IRQ/Data Frame times three, minus one (e.g. The IRQ5 Sample clock is the sixth IRQ/Data Frame, (6 x 3) - 1 = 17th clock after the rising edge of the Start Pulse).
SMSC DS - FDC37N958FR
Page 235
Rev. 09/01/99
IRQSER PERIOD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Table 74 - IRQSER SAMPLING PERIODS SIGNAL SAMPLED # OF CLOCKS PAST START Not Used 2 IRQ1 5 nSMI/IRQ2 8 IRQ3 11 IRQ4 14 IRQ5 17 IRQ6 20 IRQ7 23 IRQ8 26 IRQ9 29 IRQ10 32 IRQ11 35 IRQ12 38 IRQ13 41 IRQ14 44 IRQ15 47 the host controller may initiate a Start Frame in the second clock or more after the rising edge of the Stop Frame's pulse. Latency Latency for IRQ/Data updates over the IRQSER bus in bridge-less systems with the minimum IRQ/Data Frames of seventeen will range up to 96 clocks (3.84"S with a 25 MHz PCI Bus or 2.88"s with a 33 MHz PCI Bus). If one or more PCI to PCI Bridge is added to a system, the latency for IRQ/Data updates from the secondary or tertiary buses will be a few clocks longer for synchronous buses, and approximately double for asynchronous buses. EOI/ISR Read Latency
The SIRQ data frame will now support IRQ2 from a logical device; previously IRQSER Period 3 was reserved for use by the System Management Interrupt (nSMI). When using Period 3 for IRQ2 the user should mask off the FDC37N958FR's SMI via the ESMI Mask Register. Likewise, when using Period 3 for nSMI, the user should not configure any logical devices as using IRQ2. IRQSER Period 14 is used to transfer IRQ13. Logical devices 0 (FDC), 3 (Par Port), 4 (Ser Port 1), 5 (Ser Port 2), 6 (RTC), and 7 (KBD) will have IRQ13 as a choice for their primary interrupt. Stop Cycle Control Once all IRQ/Data Frames have completed the host controller will terminate IRQSER activity by initiating a Stop Frame. Only the host controller can initiate the Stop Frame. A Stop Frame is indicated when the IRQSER is low for two or three clocks. If the Stop Frame's low time is two clocks then the next IRQSER cycle's sampled mode is the Quiet mode; and any IRQSER device may initiate a Start Frame in the second clock or more after the rising edge of the Stop Frame's pulse. If the Stop Frame's low time is three clocks, then the next IRQSER cycle's sampled mode is the continuous mode, and only
Any serialized IRQ scheme has a potential implementation issue related to IRQ latency. IRQ latency could cause an EOI or ISR Read to precede an IRQ transition that it should have followed. This could cause a system fault. The host interrupt controller is responsible for ensuring that these latency issues are mitigated. The recommended solution is to delay EOIs and ISR Reads to the interrupt controller by the same amount as the IRQSER Cycle latency in order to ensure that these events do not occur out of order.
SMSC DS - FDC37N958FR
Page 236
Rev. 09/01/99
AC/DC Specification Issue All IRQSER agents must drive/sample IRQSER synchronously related to the rising edge of the PCI bus clock. IRQSER (SIRQ) pin uses the electrical specification of the PCI bus. Electrical parameters will follow the PCI specification section 4, sustained tri-state.
Reset and Initialization The IRQSER bus uses nPCIRST as its reset signal (nPCIRST is equivalent to using nRESET_OUT) and follows the PCI bus reset mechanism. The IRQSER pin is tri-stated by all agents while nPCIRST is active. With reset, IRQSER slaves and bridges are put into the (continuous) Idle mode. The host controller is responsible for starting the initial IRQSER cycle to collect system's IRQ/Data default values. The system then follows with the Continuous/Quiet mode protocol (Stop Frame pulse width) for subsequent IRQSER cycles. It is the host controller's responsibility to provide the default values to the 8259's and other system logic before the first IRQSER cycle is performed. For IRQSER system suspend, insertion, or removal application, the host controller should be programmed into Continuous (IDLE) mode first. This is to guarantee IRQSER bus is in Idle state before the system configuration changes.
SMSC DS - FDC37N958FR
Page 237
Rev. 09/01/99
FDC37N958FR CONFIGURATION
Overview The Configuration of the FDC37N958FR is very flexible and is based on the configuration architecture implemented in typical Plug-andPlay components. Reference Documents 1. The FDC37N958FR is designed for motherboard designs in which the resources required by their components are known. With its flexible resource allocation architecture, the FDC37N958FR allows the BIOS to assign resources at POST.
CONFIGURATION ELEMENTS Primary Configuration Address Decoder The logical devices are configured through two Configuration I/O Ports (INDEX and DATA). The BIOS uses these Configuration Ports to initialize the logical devices at POST. The MODE pin is a hardware configuration pin. The MODE pin sets the Configuration Port's default base address. Note: AEN. All I/O addresses are qualified with
PORT NAME CONFIG PORT INDEX PORT DATA PORT
Table 75 - Configuration Access Port MODE PIN = 0 (10K PULLMODE PIN = 1 (10K PULL-UP DOWN RESISTOR OR RESISTOR OR TIE TO GND) TIE TO VCC1) 0x03F0 0x0370 0x03F0 0x0370
TYPE Write (NOWS ISA I/O) Read/Write (NOWS ISA I/O) Read/Write
INDEX PORT + 1
(NOWS ISA I/O) The INDEX and DATA ports are effective only when the chip is in the Configuration State.
SMSC DS - FDC37N958FR
Page 238
Rev. 09/01/99
Typical Sequence of Configuration Operation
1. At VCC2 power-up, all logical device configuration registers are set to their internal default state. 5. 2. 3. The chip enters the Run State, and is ready to be placed into Configuration State. Place the chip into the Configuration State. Once the chip enters into the Configuration State the auto Config ports are enabled. The system sets the logical device information and activates desired logical 6. devices through the chips INDEX and DATA ports. The system sends other commands. Exit the Configuration State. returns to the RUN State. The chip
Note:
4.
Only two states are defined, Run and Configuration. In the Run State the chip will always be ready to enter the Configuration State.
SMSC DS - FDC37N958FR
Page 239
Rev. 09/01/99
Entering the Configuration State The device enters the Configuration State when the following Config Key is successfully written to the CONFIG PORT. Config Key = < 0x55> Exiting the Configuration State The device exits the Configuration State when the following Config Key is successfully written to the CONFIG PORT address. Config Key = < 0xAA> Open Mode Configuration Access Logical Device 7 contains a set of registers which may be accessed even when the
FDC37N958FR is not in Configuration State. Accessing these configurations registers from the Run State is called "Open Mode Configuration Address". The host CPU is provided a choice of four pairs of relocatable registers which are used to access these Open Mode registers. The host can use the default set or it can select a different set by programming the Index Address Global Configuration Register bits[1-0]. These bits set the base I/O address for the Open Mode Index and Data register pairs. When set, bit 7 of the Index Address Global Configuration Register enables Open Mode access to the select set of logical device 7 configuration registers. When cleared, bit 7 disables Open Mode Access. For details on the set of Open Mode Registers, see the Open Mode Registers section. Accessing Configuration Registers
Table 76 - FDC37N958FR Configuration Register Access Methods
INDEX ADDRESS CONFIGURATION REGISTER (GLOBAL CONFIG REG 0X03)
STATE
MODE PIN
CONFIG INDEX REGISTER
CONFIG DATA REGISTER
OPEN MODE INDEX REGISTER*
OPEN MODE DATA REGISTER*
Config Run
0 1 x x x x x
Bit 7 x x 0 1 1 1 1
Bit 1 x x x 0 0 1 1
Bit 0 x x x 0 1 0 1
3F0 370 n/a n/a n/a n/a n/a
3F1 371 n/a n/a n/a n/a n/a
n/a n/a n/a 0xE0 0xE2 0xE4 0xEA
n/a n/a n/a 0xE1 0xE3 0xE5 0xEB
*
Open Mode Data Registers are a subset of the configuration registers and are defined as registers 0x82 - 0x9A of Logical Device 7. Loading a value outside of the address range (0x82-0x9A) into the Open Mode Index Register will effectively disable reads/writes of the Open Mode Data Register.
SMSC DS - FDC37N958FR
Page 240
Rev. 09/01/99
Configuration Registers
Note: Hard Reset = VCC2 POR or RESET_OUT pin asserted. Soft Reset = Configuration Control Register bit 0 set to a one by the host only.
Configuration Register Map Table 77 - Configuration Register Map INDEX TYPE HARD RESET SOFT RESET CONFIGURATION REGISTER
GLOBAL CONFIGURATION REGISTERS 0x02 0x03 W R/W 0x00 0x01 or 0x02, based on mode pin 0x00 0x09 (4) 0x00 0x00 0x04 0x00 0x00 0x00 (3) 0x00 (3) 0x00 0x00 n/a Config Control Index Address
0x07 0x20 0x21 0x22 0x23 0x24 0x25 0x2C 0x2D 0x2E 0x2F
R/W R R R/W R/W R/W R/W R/W R/W R/W R/W
0x00 0x09 (4) n/a n/a n/a n/a n/a n/a n/a n/a
Logical Device Number Device ID Device Rev - Hard Wired Power Control Power Management OSC Device Mode TEST 0 TEST 1 TEST 2 TEST 3
LOGICAL DEVICE 0 CONFIGURATION REGISTERS (FDC) 0x30 0x60, 0x61 0x70 0x74 0xF0 0xF1 0xF2 R/W R/W R/W R/W R/W R/W R/W 0x00 0x03, 0xF0 0x06 0x02 0x0E 0x00 0xFF 0x00 0x03, 0xF0 0x06 0x02 n/a n/a n/a Activate Primary Base I/O Address Primary Interrupt Select DMA Channel Select FDD Mode Register FDD Option Register FDD Type Register
SMSC DS - FDC37N958FR
Page 241
Rev. 09/01/99
INDEX 0xF4 0xF5
TYPE R/W R/W
HARD RESET 0x00 0x00
SOFT RESET n/a n/a
CONFIGURATION REGISTER FDD0 FDD1
LOGICAL DEVICE 1 CONFIGURATION REGISTERS (RESERVED) LOGICAL DEVICE 2 CONFIGURATION REGISTERS (RESERVED) LOGICAL DEVICE 3 CONFIGURATION REGISTERS (Parallel Port) 0x30 0x60, 0x61 0x70 0x74 0xF0 0xF1 R/W R/W R/W R/W R/W R/W 0x00 0x00, 0x00 0x00 0x04 0x3C 0x00 0x00 0x00, 0x00 0x00 0x04 n/a n/a Activate Primary Base I/O Address Primary Interrupt Select DMA Channel Select Parallel Port Mode Register Parallel Port CnfgB shadow Register
LOGICAL DEVICE 4 CONFIGURATION REGISTERS (Serial Port 1) 0x30 0x60, 0x61 0x70 0xF0 R/W R/W R/W R/W 0x00 0x00, 0x00 0x00 0x00 0x00 0x00, 0x00 0x00 n/a Activate UART Register Base I/O Address Primary Interrupt Select Serial Port 1 Mode Register
LOGICAL DEVICE 5 CONFIGURATION REGISTERS (Serial Port 2) 0x30 0x60, 0x61 0x62, 0x63 0x74 0xF1 0xF2 0x70 0xF0 R/W R/W R/W R/W R/W R/W R/W R/W 0x00 0x00, 0x00 0x00, 0x00 0x04 0x02 0x03 0x00 0x00 0x00 0x00, 0x00 0x00, 0x00 0x04 n/a n/a 0x00 n/a Activate Primary Base I/O Address USRT Register Base I/O Address IrCC DMA Channel Select IR Options Register IR Half Duplex Timeout Primary Interrupt Select Serial Port 2 Mode Register
SMSC DS - FDC37N958FR
Page 242
Rev. 09/01/99
INDEX 0xF1
TYPE R/W
HARD RESET 0x00
SOFT RESET n/a
CONFIGURATION REGISTER IR Options Register
LOGICAL DEVICE 6 CONFIGURATION REGISTERS (RTC) 0x30 0x70 0xF0 R/W R/W R/W 0x00 0x00 0x00 0x00 0x00 n/a Activate Primary Interrupt Select Real Time Clock Mode Register
LOGICAL DEVICE 7 CONFIGURATION REGISTERS (Keyboard) 0x30 0x70 0x72 0x82
(1)
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
0x00 0x00 0x00 (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2)
0x00 0x00 0x00 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
Activate Primary Interrupt Select Second Interrupt Select System-to-8051 Mailbox Register 8051-to-System Mailbox Register Mailbox Register 2 Mailbox Register 3 Mailbox Register 4 Mailbox Register 5 Mailbox Register 6 Mailbox Register 7 Mailbox Register 8 Mailbox Register 9 Mailbox Register A Mailbox Register B Mailbox Register C Mailbox Register D Mailbox Register E Mailbox Register F PWM0 Register PWM1 Register
0x83 0x84 0x85 0x86 0x87 0x88 0x89 0x8A 0x8B 0x8C 0x8D 0x8E 0x8F 0x90 0x91 0x92 0x93
SMSC DS - FDC37N958FR
Page 243
Rev. 09/01/99
INDEX 0x94 0x95 0x96 0x97 0x98 0x99 0x9A 0x9B 0x9C 0xF0
TYPE R/W R/W R/W R/W R/W R/W R R R R/W
HARD RESET (2) (2) (2) (2) (2) (2) (2) (2) (2) 0x00
SOFT RESET n/a n/a n/a n/a n/a n/a n/a n/a n/a 0x00
CONFIGURATION REGISTER 8051STP_CLK HMEM ESMI Source Register ESMI Mask Register IR Data Register Force Disk Change Register Floppy Data Rate Select Shadow Register UART1 FIFO Control Shadow Register UART2 FIFO Control Shadow Register KRST_GA20 Register
Note 1: Registers 0x82 through 0x9A of Logical Device 7 (KBD/8051 CPU) are also accessible when the FDC37N958FR device is not in Configuration State. When in Configuration State, the host first sets the Logical Device # Register to 0x07 and then uses the INDEX and DATA ports to indirectly access these registers. When not in Configuration State, the host may simply use the INDEX and DATA ports to access these registers regardless of the value currently stored in the Logical Device # Register. Note 2: Refer to the FDC37N958FR Keyboard Specification for Reset. Note 3: Reset only by VCC2 POR. Note 4: This register is impacted by a device functional revision. See FUNCTIONAL REVISION ADDENDUM on page 308 for default values.
SMSC DS - FDC37N958FR
Page 244
Rev. 09/01/99
Chip Level (Global) Control/Configuration Registers[0x00-0x2F] The chip-level (global) registers lie in the address range [0x00-0x2F].
The INDEX PORT is used to select a configuration register in the chip. The DATA PORT is then used to access the selected register. These registers, with the exception of registers 0x82 through 0x9A of Logical Device 7, are accessible only in the Configuration State.
REGISTER
Config Control
Index Address
Table 78 - Global Configuration Registers ADDRESS DESCRIPTION Chip (Global) Control Registers Reserved, Writes are ignored, reads 0x00 return 0. 0x01 The hardware automatically clears this bit 0x02 W after the write; there is no need for software to clear the bits. Bit [0] = 1: Soft Reset; Refer to Table 77 for the soft reset value for each register. 0x03W Bit [7] When this bit is set to a "1" bits[1:0] of this register will then determine the I/O base address for an Index and Data register used to access the Open Mode Data registers (0x82-0x9A of logical device 7) when the FDC37N958FR is in the Run state. =1 Enable an Index and Data PORT to access the Open Mode Data registers when in Run State. =0 Disable INDEX PORT and DATA PORT to access Open Mode Data registers when in the Run State. (Default on VCC2 POR). Bit[6] =1 Enable CONFIG_STAT Port. =0 Disable CONFIG_STAT Port (default on VCC2 POR). Bit[5-2] Reserved - Writes are ignored, reads return 0. Bit[1-0] When in the Run State these bits set the address of the Index and Data registers used to access the Open Mode Data registers. =11 0xEA =10 0xE4 (MODE=1 VCC2 POR default) =01 0xE2 (MODE=0 VCC2 POR default) =00 oxE0 0x04 - 0x06 Reserved - Writes are ignored, reads return 0.
STATE
C
SMSC DS - FDC37N958FR
Page 245
Rev. 09/01/99
REGISTER Logical Device #
ADDRESS 0x07 R/W
DESCRIPTION A write to this register selects the current logical device. This allows access to the control and configuration registers for each logical device. Note: The Activate command operates only on the selected logical device. Reserved - Writes are ignored, reads return 0.
STATE C
Card Level Reserved Device ID Hard Wired
0x08 - 0x1F
0x20 R
Chip-Level, SMSC Defined A read-only register which provides device identification. Bit[7-0] = 0x09 when read A read-only register which provides device revision information. This register is impacted by a device functional revision. See FUNCTIONAL REVISION ADDENDUM on page 308 for default values. Bit[0] FDC Power Bit[1:2] Reserved (read as 0) Bit[3] Parallel Port Power Bit[4] Serial Port 1 Power Bit[5] Serial Port 2 Power Bit[6:7] Reserved (read as 0) =0 Power off or disabled =1 Power on or Enabled Bit[0] FDC Bit[1:2] Reserved (read as 0) Bit[3] Parallel Port Bit[4] Serial Port 1 Bit[5] Serial Port 2 Bit[6:7] Reserved (read as 0) =0 Power off or disabled =1 Power on or Enabled Bit[1:0] Reserved, set to "0" Bit[3:2] OSC =01 OSC is on, BRG clock is on when PWRGD is active, OSC is off and BRG Clock is disabled (default) =10 Same as above (01) case =00 OSC is on, BRG Clock Enabled =11 OSC is off, BTG Clock is disabled Bit[6:4] CLK_OUT Select =[0,0,0] CLK_OUT = 1.8432 MHz =[0,0,1] CLK_OUT = 14.318 MHz
C
Device Rev Hard Wired
0x21 R
C
PowerControl
0x22 R/W
C
Power Mgmt
0x23 R/W
C
OSC
0x24 R/W
C
SMSC DS - FDC37N958FR
Page 246
Rev. 09/01/99
REGISTER
ADDRESS =[0,1,0] =[0,1,1] =[1,0,0] =[1,0,1] =[1,1,X]
DESCRIPTION CLK_OUT = 16 MHz CLK_OUT = 24 MHz CLK_OUT = 48 MHz Reserved Reserved
STATE
Bit[7] nIRQ8 Polarity =0 nIRQ8 is active high =1 nIRQ8 is active low Note: This polarity bit not only affects the nIRQ8 pin, but is also reflected in the Serial IRQ sample phase for the IRQ8 Frame for the Serial IRQ Bus. Bit [1-0] Flash Timing This register is used to program the width of Flash Read (nFRD) and Flash Write (nFWR) signals during Host Flash accesses. = 0,0 : nFRD/nFWR width = 5 sclks = 0,1 : width = 4 sclks = 1,0 : width = 3 sclks = 1,1 : Reserved, do not use. Bit[2] SerIRQ Mode = 0 : Slave can initiate a cycle. = 1 : Only Host initiates cycles. Bit [4:3] Parallel Port FDC = [0:0] Normal = [0:1] PPFD1 Mode = [1:0] PPFD2 Mode = [1:1] Reserved Bit [7:5] Reserved - writes ignored, reads return "0". Reserved - Writes are ignored, reads return 0. SMSC Test Mode Registers, Reserved for SMSC. Test Modes - Reserved for SMSC. Users should not write to this register, may produce undesired results. Test Modes : Reserved for SMSC. Users should not write to this register; may produce undesired results. C
Device Mode
0x25 R/W
Chip Level Vendor Defined Test Registers
0x26 0x27-0x2B
TEST 0
0x2C
TEST 1
0x2D R/W
SMSC DS - FDC37N958FR
Page 247
Rev. 09/01/99
REGISTER TEST 2
ADDRESS 0x2E R/W
DESCRIPTION Test Modes - Reserved for SMSC. Users should not write to this register; may produce undesired results. Test Modes - Reserved for SMSC. Users should not write to this register; may produce undesired results.
STATE C
TEST 3
0x2F R/W
C
SMSC DS - FDC37N958FR
Page 248
Rev. 09/01/99
Logical Device Configuration/Control Registers [0x30-0xFF] Used to access the registers that are assigned to each logical unit. This chip supports six logical units and has six sets of logical device registers. The logical devices are Floppy, Parallel, Serial 1 and Serial 2, Real Time Clock, and Keyboard Controller. A separate set (bank) of control and configuration registers exists for each Logical Device and is selected with the Logical Device # Register (0x07).
The INDEX PORT is used to select a specific logical device register. These registers are then accessed through the DATA PORT. The Logical Device registers are accessible only when the device is in the Configuration State with the exception of registers 0x82-0x9A of Logical Device 7 which are also accessible when in the run state. The logical register addresses are listed in table 79.
Table 79 - Logical Device Configuration Registers LOGICAL DEVICE REGISTER Activate
(1)
ADDRESS (0x30)
DESCRIPTION Bits[7:1] Reserved, set to "0". Bit[0] =1 Activates the logical device currently selected through the Logical Device # register. =0 Logical device currently selected is inactive. Reserved - Writes are ignored, reads return "0". Vendor Defined - Reserved - Writes are ignored, reads return "0". Reserved - Writes are ignored, reads return "0". All logical devices contain 0x60, 0x61. Unused registers will ignore writes and return "0" when read.
STATE C
Logical Device Control Logical Device Control Memory Base Address I/O Base Address (see Table )
(0x31-0x37) (0x38-0x3f) (0x40-0x5F) (0x60-0x6F) 0x60 = addr[15:8] 0x61= addr[7:0] (0x70,072)
C C C C
Interrupt Select
0x70 is implemented for each logical device. Refer to Interrupt Configuration Register description. Only the KYBD controller uses Interrupt Select register 0x72. Unused register (0x72) will ignore writes and return "0" when read. Interrupts default to edge high (ISA compatible). Reserved - not implemented. These register locations ignore writes and return "0" when read.
C
(0x71,0x73)
SMSC DS - FDC37N958FR
Page 249
Rev. 09/01/99
LOGICAL DEVICE REGISTER DMA Channel Select
ADDRESS (0x74,0x75)
DESCRIPTION Only 0x74 is implemented for FDC , and Parallel port. 0x75 is not implemented and ignores writes and returns "0" when read. Refer to DMA Channel Configuration (seeTable 79). Reserved - not implemented. These register locations ignore writes and return "0" when read. Reserved - not implemented. These register locations ignore writes and return "0" when read. Reserved - Vendor Defined (see SMSC defined Logical Device Configuration Registers). Reserved
STATE C
32-Bit Memory Space Configuration Logical Device
(0x76-0xA8)
(0xA9-0xDF)
C
Logical Device Configuration Reserved
(0xE0-0xFE)
C
0xFF
C
Note1: A logical device will be active and powered up according to the following equation. DEVICE ON (ACTIVE) = (Activate Bit SET AND Pwr/Control Bit SET) AND (8051 Disable Bit SET) The Logical device's Activate Bit and its Pwr/Control Bit are linked such that setting or clearing one sets or clears the other. Three bits in the 8051's Disable Register (see Keyboard spec), bits D7, D6 and D4 are capable of overriding the Activate and PWR/Control bit settings for logical devices 3, 4 and 0 respectivelely. Thus clearing bit D7 of the Disable register will disable the FDC regardless of the FDC's Activate and PWR/Control bits. When D7 of the Disable register is set, the FDC's Activate and PWR/Control bits will determine the on/off state of the FDC. If the I/O Base Addr of the logical device is not within the Base I/O range as shown in the Logical Device I/O map, then read or write is not valid and is ignored.
SMSC DS - FDC37N958FR
Page 250
Rev. 09/01/99
I/O Base Address Configuration Register Description Table 80 - Logical Device, Base I/O Addresses BASE I/O LOGICAL REGISTER RANGE FIXED DEVICE INDEX (NOTE 1) BASE OFFSETS FDC 0x60,0x61 [0x100:0x0FF8] ON 8 BYTE BOUNDARIES +0 : SRA +1 : SRB +2 : DOR +3 : TSR +4 : MSR/DSR +5 : FIFO +7 : DIR/CCR
LOGICAL DEVICE NUMBER 0x00
0x01 0x02 0x03
Reserved Reserved Parallel Port 0x60,0x61 [0x100:0x0FFC] ON 4 BYTE BOUNDARIES (EPP Not supported) or [0x100:0x0FF8] ON 8 BYTE BOUNDARIES (all modes supported, EPP is only available when the base address is on an 8-byte boundary) [0x100:0x0FF8] ON 8 BYTE BOUNDARIES +0 : Data | ecpAfifo +1 : Status +2 : Control +3 : EPP Address * +4 : EPP Data 0 * +5 : EPP Data 1 * +6 : EPP Data 2 * +7 : EPP Data 3 * +400h : cfifo | ecpDfifo | tfifo | cnfgA +401h : cnfgB +402h : ecr +0 : RB/TB | LSB div +1 : IER | MSB div +2 : IIR/FCR +3 : LCR +4 : MCR +5 : LSR +6 : MSR +7 : SCR +0 : RB/TB | LSB div +1 : IER | MSB div +2 : IIR/FCR +3 : LCR +4 : MCR +5 : LSR +6 : MSR +7 : SCR
0x04
Serial Port 1
0x60,0x61
0x05
Serial Port 2 (UART)
0x60,0x61
[0x100:0x0FF8] ON 8 BYTE BOUNDARIES
SMSC DS - FDC37N958FR
Page 251
Rev. 09/01/99
LOGICAL DEVICE NUMBER 0x05
LOGICAL DEVICE Serial Port 2 (IR-USRT)
REGISTER INDEX 0x62, 0x63
BASE I/O RANGE (NOTE 1) [0x100:0x0FF8] ON 8 BYTE BOUNDARIES
FIXED BASE OFFSETS +0 : Register Block N, address 0 +1 : Register Block N, address 1 +2 : Register Block N, address 2 +3 : Register Block N, address 3 +4 : Register Block N, address 4 +5 : Register Block N, address 5 +6 : Register Block N, address 6 +7 : USRT Master Control Reg. Bank 0 0x70 : Address Register 0x71 : Data Register * Bank 1 0x74 : Address Register 0x71 : Data Register *
0x06
RTC
n/a
Not Relocatable Fixed Base Address
0x07
KYBD
n/a
Not Relocatable Fixed Base Address
0x60 : Data Register 0x64 : Command/Status Reg.
Note 1: This chip uses all ISA address bits to decode the base address of each of its logical devices. Note*: When these registers are accessed the nNOWS line is not asserted. All other registers in this table assert the nNOWS signal when accessed.
SMSC DS - FDC37N958FR
Page 252
Rev. 09/01/99
Interrupt Select Configuration Register Description Table 81 -Interrupt Select Configuration Registers Name Interrupt request level select 0 Reg Index 0x70 (R/W) Definition Bit [3-0] Select which interrupt level is used for Interrupt 0. C 0x00=no interrupt selected. 0x01=IRQ1 0x02=IRQ2 State
! ! !
0x0E= IRQ14 0x0F= IRQ15 All pin-type interrupts are edge high (except ECP/EPP). Each Logical Device's interrupts selected through this register physically select the interrupts to be used by the FDC37N958FR for either the Serial IRQ interface or for the individual pin-type ISA interrupts if selected. Setting the IRQ through this register for the Parallel Port is not reflected in the Enhanced Parallel port cnfgB register, software must set the DMA/IRQ bits in the Parallel Port logical device config register 0xF1 (Parallel Port CnfgB shadow register). It is possible for both UART1 and UART2 to share a common IRQ pin (refer to Table 80 in the Logical Device 4 SMSC defined Configuration Registers section). Note: An interrupt is activated by setting the Interrupt Request Level Select 0 register to a non-zero value AND : 1. for the FDC logical device by setting DMAEN, bit D3 of the Digital Output Register. 2. for the PP logical device by setting IRQE, bit D4 of the Control Port and in addition 3. for the PP logical device in ECP mode by clearing serviceIntr, bit D2 of the ecr. 4. for the Serial Port logical device by setting any combination of bits D0-D3 in the IER and by setting the OUT2 bit in the UART's Modem Control (MCR) Register. 5. for the RTC by (refer to the RTC section of this specification). 6. for the KYBD by (refer to the KYBD controller section of this specification). Note: IRQ pins must tri-state if not used/selected by any Logical Device (refer to Appendix A).
SMSC DS - FDC37N958FR
Page 253
Rev. 09/01/99
DMA Channel Select Configuration Register Description Table 82 - DMA Channel Select Cofiguration Registers NAME DMA Channel select 0 REG INDEX 0x74 (R/W) DEFINITION Bit [2:0] Select the DMA Channel. 0x00=DMA0 0x01=DMA1 0x02=DMA2 0x03=DMA3 0x04-0x07= No DMA active STATE C
Note:
A DMA channel is activated by setting the DMA Channel Select 0 register to [0x00-0x03] AND :
1. 2. 3.
for the FDC logical device by setting DMAEN, bit D3 of the Digital Output Register for the PP logical device in ECP mode by setting dmaEn, bit D3 of the ecr for the UART2 logical device, by setting the DMA Enable bit. Refer to the IrCC specification available from SMSC DMAREQ pins must tri-state if not used/selected by any Logical Device.
Note:
Refer to Appendix A of this section.
SMSC DS - FDC37N958FR
Page 254
Rev. 09/01/99
IRQ and DMA Enable and Disable Any time the IRQ and/or DMA channels for a logical device are disabled by a register in that logical device, the IRQ and/or nDACK must be disabled. This is in addition to the IRQ and nDACK disabled by the Configuration Registers (activate bit cleared or address outside of valid range or the Interrupt Select register set to 0x00 or the DMA Channel Select register set to 0x04). Logical Device 0 (FDC) For the following cases, the IRQ and DACK used by the FDC are disabled (high impedance), i.e., will not respond to the DREQ 1. 2. Digital Output Register (Base+2) bit D3 (DMAEN) set to "0". The FDC is in power down (disabled).
interrupt is forced to a high impedance state disabled. Logical Device 5 (Serial Port2/USART) Interrupt is disabled when: Modem Control Register (MCR) bit 2 (OUT2) When OUT2 is a logic "0", then Logical Device 5's interrupt is forced to a high impedance state, i.e., disabled. This applies to all UART/IR modes of operation. DRQ is disabled when: USRT Configuration Register B bit-0 (DMA Enable) - When the DMA Enable bit is a logic "0", then logical device 5's DRQ pin is forced to a high impedance state, i.e., disabled. When the DMA Enable bit is set to logic "1", then logical device 5's DRQ pin is active and drives low until the device issues a DMA Request at which point the DRQ pin drives high. This eliminates the need for an external pull-down resistor on the logical device 5's DRQ pin.
Logical Device 5 (Serial Port1) Modem Control Register (MCR) Bit D2 (OUT2) When OUT2 is a logic "0", then the serial port
SMSC DS - FDC37N958FR
Page 255
Rev. 09/01/99
Parallel Port SPP and EPP modes: Control Port (Base+2) bit D4 (IRQE) set to "0", IRQ is disabled (high impedance). MODE (FROM ECR REGISTER) 000 001 010 011 100 101 110 111 Real Time Clock (RTC) (refer to the RTC section) Keyboard Controller (KYBD) (refer to the keyboard controller section) PRINTER SPP FIFO ECP EPP RES TEST CONFIG
ECP Mode: (DMA) dmaEn from ecr register. IRQ - See table below.
IRQ PIN CONTROLLED BY IRQE IRQE (on) (on) IRQE IRQE (on) IRQE
PDREQ PIN CONTROLLED BY dmaEn dmaEn dmaEn dmaEn dmaEn dmaEn dmaEn dmaEn
SMSC DS - FDC37N958FR
Page 256
Rev. 09/01/99
SMSC Defined Logical Device Configuration Registers The SMSC Specific Logical Device Configuration Registers reset to their default values only on
hard resets generated by VCC2 POR or the RESET_OUT signal. These registers are not effected by soft resets.
FDC, Logical Device 0 [Logical Device Number = 0x00] REG NAME INDEX DEFINITION FDD Mode Register 0xF0 R/W Bit[0] Floppy Mode =0 Normal Floppy Mode (default) =1 Enhanced Floppy Mode 2 (OS2) Default = 0x0E Bit[1] FDC DMA Mode =0 Burst Mode is enabled =1 Non-Burst Mode (default) Bit[3:2] Interface Mode Bit 3 - IDENT Bit 2 - MFM =11 AT Mode (default) =10 (Reserved) =01 PS/2 =00 Model 30 Bit[4] Swap Drives 0,1 Mode =0 No swap (default) =1 Drive and Motor Sel 0 and 1 are swapped Bit[5] FDC Shutdown =0 FDC37N958FR FDC operates normally, FDC pins are active (default) =1 FDC core is shutdown, only I/O Writes to DOR, TDR, DSR and CCR are enabled, all Floppy Disk interface pins tri-state except for DRVDEN0, DRVDEN1, nDS0, nDS1, nMTR0, and nMTR1. Bit[6] FDC Output Type Control =0 FDC Outputs are OD24 Open Drain (default) =1 FDC Outputs are O24 push pull Bit[7] FDC Output Control =0 FDC Outputs active (default) =1 FDC Outputs tri-stated Bits 6 and 7 do not reflect the Parallel Port FDC pins.
STATE C
SMSC DS - FDC37N958FR
Page 257
Rev. 09/01/99
NAME FDD Option Register Default = 0x00
REG INDEX 0xF1 R/W
FDD Type Register Default = 0xFF
0xF2 R/W
FDD0 Default = 0x00
0xF3 R 0xF4 R/W
FDD1
0xF5 R/W
DEFINITION Bit[1:0] Reserved, set to "0" Bit[3-2] Density Select =00 Normal (default) =01 Normal (reserved for users) =101 (forced to logic "1") =110 (forced to logic "0") Bit[5:4] Media ID Polarity =00 (default) =01 =10 =11 Bit[7:6] Boot Floppy =00 FDD 0 (default) =01 FDD 1 =10 FDD 2 =11 FDD 3 Bit[1:0] Floppy Drive A Type Bit[3:2] Floppy Drive B Type Bit[5:4] Floppy Drive C Type Bit[7:6] Floppy Drive D Type Reserved, read as 0 (read only) Bit[1:0] Drive Type Select Bit[2] Read as "0" (read only) Bit[3:4] Data Rate Table Select Bit[5] Read as "0" (read only) Bit[6] Precomp Disable Bit[7] Read as "0" (read only) Refer to definition and default for 0xF4
STATE C
C
C C
C
SMSC DS - FDC37N958FR
Page 258
Rev. 09/01/99
DT0 0
DT1 0
DRVDEN0 (1) DENSEL
DRVDEN1 (1) DRATE0
DRIVE TYPE 4/2/1 MB 3.5" 2/1 MB 5.25" FDDS 2/1.6/1 MB 3.5" (3-MODE)
0 1 DRATE1 DRATE0 1 0 nDENSEL DRATE0 1 1 DRATE0 DRATE1 There are four of the following registers in the configuration data space, one for each drive. FDD0 - 0xF4/FDD1 - 0xF5 D7 0 PTS D6 PTS D5 0 D4 DRT1 D3 DRT0 D2 0 D1 DT0 D0 DT1
= 0 Use Precompensation = 1 No Precompensation
DTx = Drive Type Select DRTx = Data Rate Table Select (1) DENSEL, DRATE1 and DRATE0 map onto three output pins DRVDEN0 and DRVDEN1.
SMSC DS - FDC37N958FR
Page 259
Rev. 09/01/99
RESERVED, Logical Device 1 [Logical Device Number = 0x01] RESERVED, Logical Device 2 [Logical Device Number = 0x02] Parallel Port, Logical Device 3 [Logical Device Number = 0x03] REG NAME INDEX DEFINITION PP Mode Register Default = 0x3C 0xF0 R/W Bit [2:0] Parallel Port Mode = 100 Printer Mode (default) = 000 Standard and Bi-directional (SPP) Mode = 001 EPP-1.9 and SPP Mode = 101 EPP-1.7 and SPP Mode = 010 ECP Mode = 011 ECP and EPP-1.9 Mode = 111 ECP and EPP-1.7 Mode Bit[6:3] ECP FIFO Threshold 0111b (default) Bit[7] PP Interrupt Type Not valid when the parallel port is in the Printer Mode (100) or the Standard $ Bi-Directional Mode (000) =1 Pulsed Low, released to high-Z (665/666) =0 IRW follows nACK when parallel port in EPP Mode or [Printer, SPP, EPP] under ECP, TEST or Centronics FIFO Mode. Parallel Port CnfgB shadow Register Default = 0x00 0xF1 R/W Bit [2:0] Parallel Port DMA channel Select = 000 h/w jumpered 8-bit DMA (default) = 001 DMA channel 1 = 010 DMA channel 2 = 011 DMA channel 3 Bit [5:3] Parallel Port IRQ line Select = 000 h/w jumpered IRQ (default) = 001 IRQ 7 = 010 IRQ 9 = 011 IRQ 10 = 100 IRQ 11 = 101 IRQ 14 = 110 IRQ 15 = 111 IRQ 5 Bit [7:6] Reserved, ignores writes returns "0" on reads. The DMA/IRQ bits in this register are reflected in the Enhanced Parallel Port's read only cnfgB register. C
STATE C
SMSC DS - FDC37N958FR
Page 260
Rev. 09/01/99
Serial Port 1, Logical Device 4 [Logical Device Number = 0x04] REG NAME INDEX DEFINITION Bit[0] MIDI Mode Serial Port 1 0xF0 R/W = 0 MIDI support disabled (default) Mode Register = 1 MIDI support enabled Bit[1] High Speed Default = 0x00 = 0 High Speed Disabled (default) = 1 High Speed Enabled Bit[6:2] Reserved, set to "0" Bit[7] Share_IRQ = 0 UARTS use different IRQs = 1 UARTS share a common IRQ
STATE C
SMSC DS - FDC37N958FR
Page 261
Rev. 09/01/99
Table 83 - UART Shared Interrupt Operation UART1 UART2 IRQ PINS UART1 UART1 UART2 UART2 Share IRQ UART1 UART2 OUT2 bit IRQ State OUT2 bit IRQ State Bit Pin State Pin State This part of the table is based on the assumption that both UARTS have selected different IRQ pins. 0 Z 0 Z 0 Z Z 1 asserted 0 Z 0 1 Z 1 de0 Z 0 0 Z asserted 0 Z 1 asserted 0 Z 1 0 Z 1 de0 Z 0 asserted 1 asserted 1 asserted 0 1 1 1 asserted 1 de0 1 0 asserted 1 de1 asserted 0 0 1 asserted 1 de1 de0 0 0 asserted asserted 0 Z 0 Z 1 Z Z 1 asserted 0 Z 1 1 1 1 de0 Z 1 0 0 asserted 0 Z 1 asserted 1 1 1 0 Z 1 de1 0 0 asserted 1 asserted 1 asserted 1 1 1 1 asserted 1 de1 1 1 asserted 1 de1 asserted 1 1 1 asserted 1 de1 de1 0 0 asserted asserted It is the responsibility of the software to ensure that two IRQ's are not set to the same IRQ number. However, if they are set to the same number than no damage to the chip will result.
SMSC DS - FDC37N958FR
Page 262
Rev. 09/01/99
Serial Port 2, Logical Device 5 [Logical Device Number = 0x05] REG NAME INDEX DEFINITION Serial Port 2 oxF0 R/W Bit[0] MIDI Mode Mode Register =0 MIDI support disabled (default) =1 MIDI support enabled Bit[1] High Speed Default = 0x00 =0 High Speed Disabled (default) =1 High Speed Enabled Bit[7:2] Reserved Bit[0] Receive Polarity =0 Active High =1 Active Low (default) Bit[1] Transmit Polarity =0 Full Duplex (default) =1 Half Duplex Bit[5:3] UART/IR Mode =000 Standard COMM (default) =001 IrDA SIR-A =010 ASK-IR =011 (IrDA SIR-B) =100 (IrDA HDLC) =101 (IrDA 4PPM) =110 (Consumer) =111 (Raw IR) Bit[7:6] IrCC Output Mux =00 Active Device to COM-RX/COM-TX port (default) =01 Active Device to IRRX/IRTX port =10 Reserved-use AUX port not mapped to pins thus both IR and COM ports are inactive =11 Reserved, all ports are inactive Bit[7:0] These bits set the half duplex time-out for the IR port. This value is 0 to 10ms in 100"s increments =0x00 blank RX/TX during Transmit/Receive =0x01 blank TX/TX during Xmit/Rcv + 100"s ...... =0x64 blank RX/TX during Xmit/Rcv +10ms =0x65 - 0xFF : Reserved
STATE C
IR Option Register Default = 0x00 This register sets the IR options and uses the same bit definitions as the FDC37C93x
oxF1 R/W
C
IR Half Duplex Timeout Default = 0x03
0xF2 R/W
EN_1 : Bits [5:0] of the IR Option Configuration Register must be reconciled with bits[5:0] of the "USRT Configuration Register A" control register in the IrCC Block, detailed in the IrCC specification. Additionally bits [7:6] of the IR Option Configuration Register must be reconciled with bits[5:4] of the
SMSC DS - FDC37N958FR
Page 263
Rev. 09/01/99
"USRT Configuration Register B" control register in the IrCC Block. The last register written should update the information in both registers. Both sets of registers can use common latches to store the information. RTC, Logical Device 6 [Logical Device Number = 0x06] REG INDEX DEFINITION 0xF0 R/W Bit[0] = 1 : Lock CMOS RAM 80-9Fh Bit[1] = 1 : Lock CMOS RAM A0-BFh Bit[2] = 1 : Lock CMOS RAM C0-DFh Bit[3] = 1 : Lock CMOS RAM E0-FEh Bit[7:4] Reserved, set to "0" Once set, bit[3:0] can not be cleared by a write; bits[3:0] are cleared on VCC2 Power On Reset, VCC2 Power Off, or upon a Hard Reset(RESET_OUT asserted). Once lock bits are set, both the Host and the 8051 are locked out of accessing the locked locations as long as VCC1 and VCC2 are active. When VCC2 goes to 0V, the lock bits are cleared and the 8051 can access this RAM while RESET_OUT is asserted.
NAME RTC Mode Register Default = 0x00
STATE C
SMSC DS - FDC37N958FR
Page 264
Rev. 09/01/99
Bit[0] : ENAB_P92 = 0 : Port 92 Disabled = 1 : Port 92 Enabled Bit [7:0] : Reserved, set to "0". Note 1: Refer to the 8051 section for descriptions of these registers.
NAME System-to-8051 Mailbox Register 8051-to-System Mailbox Register Mailbox Register 2-F PWM0 Register PWM1 Register 8051STP_CLK HMEM ESMI Source Register ESMI Mask Register IR Data Register Force Disk Change Register Floppy Data Rate Select Shadow Register UART1 FIFO Control Shadow Register UART2 FIFO Control Shadow Register KRST_GA20
KBYD, Logical Device 7 [Logical Device Number = 0x07] REG INDEX DEFINITION 0x82 R/W Note 1 0x83 R/W 0x84-0x91 R/W 0x92 R/W 0x93 R/W 0x94 R/W 0x95 R/W 0x96 R/W 0x97 R/W 0x98 R/W 0x99 R/W 0x9A R Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 See the description of the Force Disk Change Register in the FDC section. See the description of the Floppy Data Rate Select Register in the FDC section. This register provides a means of reading UART1's FIFO Control Register. See the UART section. This register provides a means of reading UART2's FIFO Control Register. See the UART section.
STATE C, R C, R C, R C, R C, R C, R C, R C, R C, R C, R C, R C, R
0x9B R
C, R
0x9C R
C. R
0xF0 R/W
SMSC DS - FDC37N958FR
Page 265
Rev. 09/01/99
Open Mode Registers Below is a concise table of all of the Open Mode accessible registers on the FDC37N958FR
device. Open Mode registers can be accessed through the chip's Open Mode Index and Data registers and are signified by the prefix IDX in front of their hexidecimal address.
Table 84 - Open Mode Registers
OPEN MODE INDEX ADDRESS IDX 82h SYSTEM R/W R/W 8051 ADDRESS (7F00 +) 08h 8051 R/W RC POWER SOURCE VCC1 VCC1 POR 00 VCC2 POR ZERO WAIT STATE (1) Y SEE PAGE # 192
Systemto-8051 Mailbox Register 0 8051-toSystem Mailbox Register 1 Mailbox Register [2-F] PWM0 Register PWM1 Register 8051STP _CLK HMEM ESMI Source Register ESMI Mask Register IR Data Register Force Disk Change Register Floppy Data Rate Select Shadow Register UART1 FIFO Control Shadow Register UART2 FIFO
NOTES 2
IDX 83h
RC
09h
R/W
VCC1
00
Y
3
192
IDX 84h-91h
R/W
0A-17h
R/W
VCC1
00h
Y
193
IDX 92h IDX 93h IDX 94h IDX 95h IDX 96h
R/W R/W R/W R/W R/W
25h 26h ------
R/W R/W -------------
VCC1 VCC1 VCC1 VCC1 VCC2
00h 00h 00h 03h 03h 00h
Y Y Y Y Y 5 5, 6
200 200 168 166 193
------
IDX 97h
R/W
------
-----
VCC2
00h
Y
193
IDX 98h IDX99h
R/W R/W
-----------
---------
VCC2 VCC2
00h 03h
Y Y
206 278
IDX9A
R
------
-----
VCC2
N/A
Y
278
IDX9B
R
------
-----
VCC2
00h
Y
-----
IDX9C
R
------
-----
VCC2
00h
Y
-----
SMSC DS - FDC37N958FR
Page 266
Rev. 09/01/99
OPEN MODE INDEX ADDRESS Control Shadow Register
SYSTEM R/W
8051 ADDRESS (7F00 +)
8051 R/W
POWER SOURCE
VCC1 POR
VCC2 POR
ZERO WAIT STATE (1)
NOTES
SEE PAGE #
Notes: 1. When accessed for a read or write by the system, the registers marked with a "Y" will drive the zero wait state pin active. 2. Interrupt is cleared when read by the 8051. 3. Interrupt is cleared when read by the host. 4. When IRESET_OUT is cleared (written from "1" to"0") 8051STP_CLK bit D0 as well as HMEM bits D1 and D0 are all set to "1". 5. These registers are reset 500"s to 1ms following the condition that BOTH VCC2 is valid and PWRGD is asserted given that the RTC is in normal mode and the VRT bit is set (refer to the RTC section). If the RTC is not in normal mode and/or the VRT bit is not set then these registers are reset within 10"s following the condition that BOTH VCC2 is valid and PWRGD is asserted. System Shadow Registers The FDC37N958FR makes the following Control Registers readable by supplying a set of Index Sys. index IDX99 IDX9 A Sys R/W R R
8051 address (7F00+) 8051 R/W
Force Diskchange Floppy Data Rate Select Shadow Register UART1 FIFO Control Shadow Register UART2 FIFO Control Shadow Register
-----------
N/A N/A
Registers accessable either through Logical Device 7 when in Confuration State or through the Open Mode Index and Data registers when in Run State. Zero Power VCC1 VCC2 Wait Source POR POR State (9) Notes VCC2 03h -----VCC2 N/A ------
IDX9 B
R
------
N/A
VCC2
00h
IDX9 C
R
------
N/A
VCC2
00h
SMSC DS - FDC37N958FR
Page 267
Rev. 09/01/99
8051 R/W System R/W Bit Def
D7 N/A R Soft Reset
Floppy Data Rate Select Shadow Register D6 D5 D4 D3 D2 N/A N/A N/A N/A N/A R Power Down R 0 R
PRECOMP 2
D1 N/A R
D0 N/A R
R
PRECOMP 1
R
PRECOMP 0
Note:
Data Data Rate Rate Select 0 Select 1 D1 and D0 are updated by a write to the Floppy Data Rate or CCR registers. Bits D7-D2 are updated by a write to the Floppy Data Rate register only. Force Diskchange D1 R/W
1 = Force a diskchange indication when the DIR register (of the Floppy controller) is read, gated with Drive Select 0 or 1. These bits can be written to a "1" but are not clearable by the software. These bits are reset when nSTEP input is active with the proper drive select to the drive occurs. D0 is cleared on nSTEP and Drive Select 0; D1 is cleared on nSTEP and Drive Select 1. Equivalent logic: when read DIR bit 7 = (Drive_Sel_0 & D0) OR (Drive_Sel_1 & D1) OR DSK_CHG
System R/W Bit Def
D7-D2 R Reserved
D0 R/W
SMSC DS - FDC37N958FR
Page 268
Rev. 09/01/99
ELECTRICAL SPECIFICATIONS
MAXIMUM GUARANTEED RATINGS* Operating Temperature Range .................................................................................................... 0 C to +70 C o o Storage Temperature Range .....................................................................................................-55 to +150 C o Lead Temperature Range (soldering, 10 seconds).............................................................................. +325 C Positive Voltage on any pin, with respect to Ground .......................................................................... Vcc+0.3V Negative Voltage on any pin, with respect to Ground ..............................................................................-0.3V Maximum Vcc ............................................................................................................................................... +7V *Stresses above those listed above could cause permanent damage to the device. This is a stress rating only and functional operation of the device at any other condition above those indicated in the operation sections of this specification is not implied. Note: When powering this device from laboratory or system power supplies, it is important that the Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit voltage spikes on their outputs when the AC power is switched on or off. In addition, voltage transients on the AC power line may appear on the DC output. If this possibility exists, it is suggested that a clamp circuit be used. Table 85 - Operating Conditions PARAMETER MIN TYP Vbat for RTC 2.7 3.0 Vbat for RTC Ibat<2a Vcc for 8051 System Vcc Serial Comm Clock RTC Crystal System Clock
o o
SYMBOL Vcc0
MAX 5.5 3.3
UNITS V
Vcc1 Vcc2 32 MHZ_IN XTAL1/XTAL2 14.31MHZ_IN
4.5 4.5
5.0 5.0 33 32.768 14.318
5.5 5.5
V V MHz KHz MHz
SMSC DS - FDC37N958FR
Page 269
Rev. 09/01/99
POWER DISTRIBUTION Table 86 - Type 1 Device VCC0, "VBAT" (RTC) VCC1 (8051 + OTHER) 0 volts 0 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts
Powerdown <20"a Run on 4 MHz Run on 4 MHz 14 Meg input
VCC2 (SI/O) 0 volts 0 volts 0 volts 5 volts 5 volts
RTC only <1ua Powerdown <20"a Run on 4 MHz Run on 4 MHz 14 Meg input VCC2 < 3.7V ; lock-out host VCC1 < 2.5V ; lock-out 8051 Type 1 Device: Type 2 Device:
Table 87 - Type 2 Device VCC0, "VBAT" (RTC) VCC1 (8051 + OTHER) 0 volts 0 volts 3.3 volts 0 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts 4.7 volts
VCC2 (SI/O) 0 volts 0 volts 0 volts 0 volts 5 volts 5 volts
Vcc0 and Vcc1 tied together and sourced by main battery supply. Vcc0 connected to Vbat. Vcc1 connected to main battery supply.
Vcc2 is switched supply from either main battery or AC if plugged in.
SMSC DS - FDC37N958FR
Page 270
Rev. 09/01/99
DC SPECIFICATIONS DC ELECTRICAL CHARACTERISTICS (TA = 0C - 70C, VCC = +5.0 V 10%) PARAMETER SYMBOL MIN TYP MAX UNITS COMMENTS I Type Input Buffer Low Input Level High Input Level IS Type Input Buffer Low Input Level High Input Level Schmitt Trigger Hysteresis ISP Type Input Buffer with 90 "A weak pull-up 0.8 Low Input Level High Input Level Schmitt Trigger Hysteresis ICLK Input Buffer Low Input Level High Input Level OCLK2 Crystal Oscillator Output ICLK2 Crystal Oscillator Input VILCK VIHCK 3.0 0.4 V V VILIS 2.2 VIHIS 250 VHYS mV V Schmitt Trigger V Schmitt Trigger VILIS VIHIS VHYS 2.2 250 0.8 V V mV Schmitt Trigger Schmitt Trigger VILI VIHI 2.0 0.8 V V TTL Levels
Use a 32 KHz parallel resonant crystal oscillator. The load capacitors are seen by the crystal as two capacitors in series and should be approximately 2 times the Co of the actual crystal used (C1=2Co). For example, a 7.5pF crystal should use two 15pF capacitors for proper loading. The 1 Meg reg resistor (see .6"A TLM) creates a very low current to bias the XTAL1 input to ground and shunt any extraneous DC offset.
Input Leakage (All I and IS buffers except PWRGD & VCC1_PWRGD) Low Input Leakage High Input Leakage Input Current PWRGD IIL IIH IOH -10 -10 75 +10 +10 150 "A "A mA VIN = 0 VIN = VCC VIN = 0
SMSC DS - FDC37N958FR
Page 271
Rev. 09/01/99
PARAMETER O4 Type Buffer Low Output Level High Output Level Output Leakage OD4 Type Buffer Low Output Level Output Leakage O8 Type Buffer Low Output Level High Output Level Output Leakage OD8 Type Buffer Low Output Level Output Leakage O24 Type Buffer Low Output Level High Output Level Output Leakage OD24 Type Buffer Low Output Level High Output Level Output Leakage Supply Current Active Supply Current Standby
SYMBOL
MIN
TYP
MAX
UNITS
COMMENTS
VOL VOH IOL 2.4 -10
0.4
V V
IOL = 4 mA IOH = -2 mA VIN = 0 to VCC
+10
"A
VOL IOH -10
0.4 +10
V "A
VOL = 4 mA IOH = 0 to VCC
VOL VOH IOL 2.4 -10
0.4
V V
IOL = 8 mA IOH = -4 mA VIN = 0 to VCC
+10
"A
VOL IOH -10
0.4 +10
V "A
VOL = 8 mA IOH = 0 to VCC
VOL VOH IOL 2.4 -10
0.4
V V
IOL = 24 mA IOH = -12 mA VIN = 0 to VCC
+10
"A
VOL VOH IOL ICC ICSBY TBD 2.4 -10
0.4
V V
IOL = 24 mA IOH = -50 mA VIN = 0 to Vcc All outputs open.
+10 TBD TBD
"A mA "A
SMSC DS - FDC37N958FR
Page 272
Rev. 09/01/99
AC SPECIFICATIONS AC Test Conditions CAPACITANCE TA = 25C; fc = 1MHz; Vcc = 5V PARAMETER SYMBOL LIMITS MIN Clock Input Capacitance Input Capacitance Output Capacitance CIN CIN COUT TYP MAX 20 10 20 pF pF pF All pins except pin under test tied to AC ground
UNIT
TEST CONDITION
SMSC DS - FDC37N958FR
Page 273
Rev. 09/01/99
LOAD CAPACITANCE
For the timing diagrams shown, the following capacitive loads are used. Table 88 - Capacitive Loading CAPACITANCE TOTAL (pF) NAME 240 nALF 240 nSTB 120 EMCLK 120 EMDAT 120 IMCLK 50 IMDAT 50 KBDAT 240 KBCLK 240 PS2DAT 240 PS2CLK 240 nNOWS 240 FAD[0:7] 240 FA[8:17] 240 nFRD 240 nFWR 100 FALE 100 KSO[0:13] 100 SIRQ 100 FPD 100 AB_DATA 100 AB_CLK 240 IRTX 240 PWM[0:1] 240 nRESET_OUT
NAME SD[0:7] IOCHRDY IRQ[1,3,4, 6-8, 12] nSMI DRQ[0:1] 32KHz_OUT 24MHz_OUT nWGATE nWDATA nHDSEL nDIR nSTEP nDS[1:0] nMTR[1:0] DRVDEN[1:0] TXD1 nRTS1 nDTR1 TXD2 nRTS2 nDTR2 PD[0:7] nSLCTIN nINIT
CAPACITANCE TOTAL (pF) 240 240 240 240 240 240 240 240 240 240 240 100 100 50 50 50 100 150 50 100 100 50 50 240
SMSC DS - FDC37N958FR
Page 274
Rev. 09/01/99
TIMING DIAGRAMS
t3 SA[x] t4 SD[7:0] t2 t1 nIOW t5
FIGURE 30 - FASTGATEA20 IOW TIMING In order to use the FastGATEA20 speed-up mechanism, data must be available by the falling edge of nIOW. Table 89 - FastGATEA20 IOW Timing Parameters DESCRIPTION MIN TYP SA[x] Valid to nIOW Asserted SD[7:0] Valid to nIOW Asserted nIOW Asserted to SA[x] Invalid nIOW Deasserted to SD[7:0] Invalid nIOW Deasserted to nIOW or nIOR Asserted 10 0 10 0 100
NAME t1 t2 t3 t4 t5
MAX
UNITS ns ns ns ns ns
SMSC DS - FDC37N958FR
Page 275
Rev. 09/01/99
t10 AEN t3 SA[x] t2 t1 nIOW t5 SD[x] DATA VALID t7 FINTR t8 PINTR t9 IBF t4 t6
FIGURE 31 - ISA IO WRITE Table 90 - ISA IO Write Parameters DESCRIPTION MIN SA[x] and AEN Valid to nIOW Asserted nIOW Asserted to nIOW Deasserted nIOW Asserted to SA[x] Invalid SD[x] Valid to nIOW Deasserted SD[x] Hold from nIOW Deasserted nIOW Deasserted to nIOW Asserted nIOW Deasserted to FINTR Deasserted (Note 1) nIOW Deasserted to PINTER Deasserted (Note 2) IBF (internal signal) Asserted from nIOW Deasserted nIOW Deasserted to AEN Invalid 10 10 80 10 45 0 25 55 260 40
NAME t1 t2 t3 t4 t5 t6 t7 t8 t9 t10
TYP
MAX
UNITS ns ns ns ns ns ns ns ns ns ns
Note 1: FINTR refers to the IRQ used by the floppy disk logical device. Note 2: PINTR refers to the IRQ used by the parallel port logical device.
SMSC DS - FDC37N958FR
Page 276
Rev. 09/01/99
AEN SA[x] t1 nIOR SD[x] PD[x], nERROR, PE, SLCT, ACK, BUSY FINTER PINTER PCOBF AUXOBF1 nIOR/nIOW t8 t9 t7 t4
D A TA V A LI D
t13 t3
t2 t5
t6
t10
t11 t12
FIGURE 32 - ISA IO READ CYCLE
SMSC DS - FDC37N958FR
Page 277
Rev. 09/01/99
NAME t1 t2 t3 t4 t5 t6 t8 t8 t7 t9 t10 t11 t12 t13 Note 1: Note 2: Note 3: Note 4: Note 5:
Table 91 - ISA IO Read Timing Parameters DESCRIPTION MIN TYP SA[x] and AEN Valid to nIOR Asserted nIOR Asserted to nIOR Deasserted nIOR Asserted to SA[x] Invalid nIOR Asserted to Data Valid Data Hold/Float from nIOR Deasserted nIOR Deasserted to nIOR Asserted nIOR Asserted after nIOW Deasserted nIOR/nIOR, nIOW/nIOW Transfers from/to ECP FIFO Parallel Port Setup to nIOR Asserted nIOR Asserted to PINTER Deasserted nIOR Deasserted to FINTER Deasserted nIOR Deasserted to PCOBF Deasserted (Notes 3,5) nIOR Deasserted to AUXOBF1 Deasserted (Notes 4,5) nIOR Deasserted to AEN Invalid FINTR refers to the IRQ used by the floppy disk. PINTR refers to the IRQ used by the parallel port. PCOBF is used for the Keyboard IRQ. AUXOBF1 is used for the Mouse IRQ. Applies only if deassertion is performed in hardware. 10 10 25 80 150 10 50 10
MAX
UNITS ns ns ns
50 25
ns ns ns ns ns
20 55 260 80 80
ns ns ns ns ns ns
SMSC DS - FDC37N958FR
Page 278
Rev. 09/01/99
t1 t2 CLOCKI t2
FIGURE 33 - INPUT CLOCK TIMING Table 92 - Input Clock Timing Parameters DESCRIPTION MIN TYP Clock Cycle Time for 14.318 MHz Clock High Time/Low Time for 14.318 MHz Clock Rise Time/Fall Time (not shown) 25 5
NAME t1 t2 tr , tf
MAX 65
UNITS ns ns ns
SMSC DS - FDC37N958FR
Page 279
Rev. 09/01/99
t15 AEN t16 t3 t2 FDRQ, PDRQ t1 nDACK t12 t14 t11 t6 t5 nIOR or nIOW t7 DATA (DO-D7) t13 TC DATA VALID t8 t4
t10 t9
FIGURE 34 - DMA TIMING (SINGLE TRANSFER MODE) Table 93 - DMA Timing (Single Transfer Mode) Parameters
NAME t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 t13 t14 t15 t16 DESCRIPTION nDACK Delay Time from FDRQ High DRQ Reset Delay from nIOR or nIOW FDRQ Reset Delay from nDACK Low nDACK Width nIOR Delay from FDRQ High nIOW Delay from FDRQ High Data Access Time from nIOR Low Data Set Up Time to nIOW High Data to Float Delay from nIOR High Data Hold Time from nIOW High nDACK Set Up to nIOW/nIOR Low nDACK Hold after nIOW/nIOR High TC Pulse Width AEN Set Up to nIOR/nIOW AEN Hold from nDACK TC Active to PDRQ Inactive 40 10 10 5 10 60 40 10 100 60 150 0 0 100 MIN 0 100 100 TYP MAX UNITS ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns
SMSC DS - FDC37N958FR
Page 280
Rev. 09/01/99
t15 AEN t16 t3 t2 FDRQ, PDRQ t1 nDACK t12 t14 t11 t6 nIOR or nIOW t5 t8 t4
t7 DATA (DO-D7) DATA VALID t13 TC
t10 t9 DATA VALID
FIGURE 35 - DMA TIMING (BURST TRANSFER MODE) Table 94 - DMA Timing (Burst Transfer Mode) Parameters
NAME t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 t13 t14 t15 t16 DESCRIPTION nDACK Delay Time from FDRQ High DRQ Reset Delay from nIOR or nIOW FDRQ Reset Delay from nDACK Low nDACK Width nIOR Delay from FDRQ High nIOW Delay from FDRQ High Data Access Time from nIOR Low Data Set Up Time to nIOW High Data to Float Delay from nIOR High Data Hold Time from nIOW High nDACK Set Up to nIOW/nIOR Low nDACK Hold after nIOW/nIOR High TC Pulse Width AEN Set Up to nIOR/nIOW AEN Hold from nDACK TC Active to PDRQ Inactive 40 10 10 5 10 60 40 10 100 60 150 0 0 100 MIN 0 100 100 TYP MAX UNITS ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns
SMSC DS - FDC37N958FR
Page 281
Rev. 09/01/99
t3 nDIR t4 t1 nSTEP t2
t5 nDS0-3 t6 nINDEX t7 nRDATA t8 nWDATA nIOW t9 nDS0-3, MTR0-3 t9
FIGURE 36 - FLOPPY DISK DRIVE TIMING (AT MODE) Table 95 - Floppy Disk Drive Timaing (AT Mode) Parameters DESCRIPTION MIN TYP MAX nDIR Set Up to STEP Low nSTEP Active Time Low nDIR Hold Time after nSTEP nSTEP Cycle Time nDS0-3 Hold Time from nSTEP Low nINDEX Pulse Width nRDATA Active Time Low nWDATA Write Data Width Low nDS0-3, MTRO-3 from End of nIOW 4 24 96 132 20 2 40 .5 25
NAME t1 t2 t3 t4 t5 t6 t7 t8 t9
UNITS X* X* X* X* X* X* ns Y* ns
*X specifies one MCLK period and Y specifies one WCLK period. MCLK = Controller Clock to FDC WCLK = 2 x Data Rate
SMSC DS - FDC37N958FR
Page 282
Rev. 09/01/99
nIOW
t1 nRTSx, nDTRx t5 IRQx nCTSx, nDSRx, nDCDx t2 IRQx nIOW t4
t6
t3 IRQx nIOR nRIx
FIGURE 37 - SERIAL PORT TIMING Table 96 - Serial Port Timing Parameters DESCRIPTION MIN TYP nRTSx, nDTRx Delay from nIOW IRQx Active Delay from nCTSx, nDSRx, nDCDx IRQx Inactive Delay from nIOR (Leading Edge) IRQx Inactive Delay from nIOW (Trailing Edge) IRQx Inactive Delay from nIOW IRQx Active Delay from nRIx 10
NAME t1 t2 t3 t4 t5 t6
MAX 200 100 120 125 100 100
UNITS ns ns ns ns ns ns
SMSC DS - FDC37N958FR
Page 283
Rev. 09/01/99
PD0- PD7 t6 nIOW
nINIT, nSTROBE. nAUTOFD, SLCTIN nACK t2 nPINTR (SPP)
t1
PINTR (ECP or EPP Enabled) nFAULT (ECP) nERROR (ECP) t5 t2 PINTR t3
t4
t3
FIGURE 38 - PARALLEL PORT TIMING Table 97 - Parallel Port Timing Parameters DESCRIPTION MIN TYP PD0-7, nINIT, nSTROBE, nAUTOFD Delay from nIOW PINTR Delay from nACK, nFAULT PINTR Active Low in ECP and EPP Modes PINTR Delay from nACK nERROR Active to PINTR Active PD0 - PD7 Delay from IOW Active 200
NAME t1 t2 t3 t4 t5 t6
MAX 100 60 300 105 105 100
UNITS ns ns ns ns ns ns
SMSC DS - FDC37N958FR
Page 284
Rev. 09/01/99
t18 A0-A10 t9 SD<7:0> nIOW IOCHRDY t13 t22 t20 t1 PD<7:0> t14 t16 t3 t4 t17 t8 t10 t11 t12 t19
nWRITE
t2 t5
nDATAST nADDRSTB
t6 nWAIT PDIR t21
t15
t7
FIGURE 39 - EPP 1.9 DATA OR ADDRESS WRITE CYCLE
SMSC DS - FDC37N958FR
Page 285
Rev. 09/01/99
NAME t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 t13 t14 t15 t16 t17 t18 t19 t20 t21 t22
Table 98 - EPP 1.9 Data or Address Write Parameters DESCRIPTION MIN TYP MAX nIOW Asserted to PDATA Valid nWAIT Asserted to nWRITE Change (Note 1) nWRITE to Command Asserted nWAIT Deasserted to Command Deasserted (Note 1) nWAIT Asserted to PDATA Invalid (Note 1) Time Out Command Deasserted to nWAIT Asserted SDATA Valid to nIOW Asserted nIOW Deasserted to DATA Invalid nIOW Asserted to IOCHRDY Asserted nWAIT Deasserted to IOCHRDY Deasserted (Note 1) IOCHRDY Deasserted to nIOW Deasserted nIOW Asserted to nWRITE Asserted nWAIT Asserted to Command Asserted (Note 1) Command Asserted to nWAIT Deasserted PDATA Valid to Command Asserted Ax Valid to nIOW Asserted nIOW Asserted to Ax Invalid nIOW Deasserted to nIOW or nIOR Asserted nWAIT Asserted to nWRITE Asserted (Note 1) nWAIT Asserted to PDIR Low PDIR Low to nWRITE Asserted 0 60 5 60 0 10 0 10 0 0 60 10 0 60 0 10 40 10 40 60 0 0 185 70 210 10 24 160 12 50 185 35 190
UNITS ns ns ns ns ns ms ns ns ns ns ns ns ns ns ms ns ns ns ns ns ns ns
Note 1: nWAIT must be filtered to compensate for ringing on the parallel bus cable. WAIT is consideredto have settled after it does not transition for a minimum of 50 nsec.
SMSC DS - FDC37N958FR
Page 286
Rev. 09/01/99
t20 A0-A10 IOR t19 t13 SD<7:0> t8 t24 t23 PDIR t9 t21 nWRITE t2 t25 PD<7:0> t28 t26 t1 DATASTB ADDRSTB t15 t7 nWAIT t6 t14 t3 t5
PData bus driven by peripheral
t11 t12 t18 t10
t22
IOCHRDY
t27
t17
t4
t16
FIGURE 40 - EPP 1.9 DATA OR ADDRESS READ CYCLE
SMSC DS - FDC37N958FR
Page 287
Rev. 09/01/99
Table 99 - EPP 1.9 Data or Address Read Cycle Timing Parameters
NAME t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 t13 t14 t15 t16 t17 t18 t19 t20 t21 t22 t23 t24 t25 t26 t27 t28 DESCRIPTION PDATA Hi-Z to Command Asserted nIOR Asserted to PDATA Hi-Z nWAIT Deasserted to Command Deasserted (Note 1) Command Deasserted to PDATA Hi-Z Command Asserted to PDATA Valid PDATA Hi-Z to nWAIT Deasserted PDATA Valid to nWAIT Deasserted nIOR Asserted to IOCHRDY Asserted nWRITE Deasserted to nIOR Asserted (Note 2) nWAIT Deasserted to IOCHRDY Deasserted (Note 1) IOCHRDY Deasserted to nIOR Deasserted nIOR Deasserted to SDATA Hi-Z (Hold Time) PDATA Valid to SDATA Valid nWAIT Asserted to Command Asserted Time Out nWAIT Deasserted to PDATA Driven (Note 1) nWAIT Deasserted to nWRITE Modified (Notes 1,2) SDATA Valid to IOCHRDY Deasserted (Note 3) Ax Valid to nIOR Asserted nIOR Deasserted to Ax Invalid nWAIT Asserted to nWRITE Deasserted nIOR Deasserted to nIOW or nIOR Asserted nWAIT Asserted to PDIR Set (Note 1) PDATA Hi-Z to PDIR Set nWAIT Asserted to PDATA Hi-Z (Note 1) PDIR Set to Command nWAIT Deasserted to PDIR Low (Note 1) nWRITE Deasserted to Command MIN 0 0 60 0 0 0 0 0 0 60 0 0 0 0 10 60 60 0 40 10 0 40 60 0 60 0 60 1 180 20 180 185 10 185 40 75 195 12 190 190 85 160 24 TYP MAX 30 50 180 UNITS ns ns ns ns ns ms ns ns ns ns ns ns ns ns ms ns ns ns ns ns ns ns ns ns ns ns ns ns
Note 1: nWAIT is considered to have settled after it does not transition for a minimum of 50 ns. Note 2: When not executing a write cycle, EPP nWRITE is inactive high. Note 3: 85 is true only if t7 = 0.
SMSC DS - FDC37N958FR
Page 288
Rev. 09/01/99
t18 A0-A10 t9 SD<7:0> t17 t8 t6 t12 t10 t20 t19
nIOW
IOCHRDY t13 nWRITE t1 PD<7:0>
t11
t2
t5
t16 t3 nDATAST nADDRSTB
t4
t21 nWAIT PDIR
FIGURE 41 - EPP 1.7 DATA OR ADDRESS WRITE CYCLE
SMSC DS - FDC37N958FR
Page 289
Rev. 09/01/99
NAME t1 t2 t3 t4 t5 t6 t8 t9 t10 t11 t12 t13 t16 t17 t18 t19 t20 t21
Table 100 - EPP 1.7 Data or Address Write Cycle Timing Parameters DESCRIPTION MIN TYP MAX nIOW Asserted to PDATA Valid Command Deasserted to nWRITE Change nWRITE to Command nIOW Deasserted to Command Deasserted (Note 2) Command Deasserted to PDATA Invalid Time Out SDATA Valid to nIOW Asserted nIOW Deasserted to DATA Invalid nIOW Asserted to IOCHRDY Asserted nWAIT Deasserted to IOCHRDY Deasserted IOCHRDY Deasserted to nIOW Deasserted nIOW Asserted to nWRITE Asserted PDATA Valid to Command Asserted Ax Valid to nIOW Asserted nIOW Deasserted to Ax Invalid nIOW Deasserted to nIOW or nIOR Asserted nWAIT Asserted to IOCHRDY Deasserted Command Deasserted to nWAIT Deasserted 0 10 0 10 40 10 100 45 50 35 50 10 10 0 0 24 40 12 0 0 5 50 40 35 50
UNITS ns ns ns ns ns ms ns ns ns ns ns ns ns ns ms ns ns ns
Note 1: nWRITE is controlled by clearing the PDIR bit to "0" in the control register before performing an EPP Write. Note 2: The number is only valid if nWAIT is active when IOW goes active.
SMSC DS - FDC37N958FR
Page 290
Rev. 09/01/99
t20 A0-A10 t15 t19 nIOR t13 SD<7:0> t8 t3 IOCHRDY t10 t11 t22
t12
nWRITE t5 PD<7:0> t23 nDATASTB nADDRSTB t2 t4
t21 nWAIT
PDIR
FIGURE 42 - EPP 1.7 DATA OR ADDRESS READ CYCLE Table 101 - EPP 1.7 Data or Address Read Cycle Timing Parameters
NAME t2 t3 t4 t5 t8 t10 t11 t12 t13 t15 t19 t20 t21 t22 t23 DESCRIPTION nIOR Deasserted to Command Deasserted nWAIT Asserted to IOCHRDY Deasserted Command Deasserted to PDATA Hi-Z Command Asserted to PDATA Valid nIOR Asserted to IOCHRDY Asserted nWAIT Deasserted to IOCHRDY Deasserted IOCHRDY Deasserted to nIOR Deasserted nIOR Deasserted to SDATA High-Z (Hold Time) PDATA Valid to SDATA Valid Time Out Ax Valid to nIOR Asserted nIOR Deasserted to Ax Invalid Command Deasserted to nWAIT Deasserted nIOR Deasserted to nIOW or nIOR Asserted nIOR Asserted to Command Asserted 10 40 10 0 40 55 0 0 40 40 12 0 0 0 24 50 MIN TYP MAX 50 40 UNITS ns ns ns ns ns ns ns ns ns ms ns ns ns ns ns
Note:
WRITE is controlled by setting the PDIR bit to "1" in the control register before performing an EPP Read.
SMSC DS - FDC37N958FR
Page 291
Rev. 09/01/99
ECP PARALLEL PORT TIMING Parallel Port FIFO (Mode 101) The standard parallel port is run at or near the peak 500Kbytes/sec allowed in the forward direction using DMA. The state machine does not examine nACK, but begins the next transfer based on Busy. Refer to figure 32. ECP Parallel Port Timing The timing is designed to allow operation at approximately 2.0 Mbytes/sec over a 15ft cable. If a shorter cable is used then the bandwidth will increase. Forward-Idle When the host has no data to send it keeps HostClk () high and the peripheral will leave PeriphClk (Busy) low. Forward Data Transfer Phase The interface transfers data and commands from the host to the peripheral using an interlocked PeriphAck and HostClk. The peripheral may indicate its desire to send data to the host by asserting nPeriphRequest. The Forward Data Transfer Phase may be entered from the Forward-Idle Phase. While in the Forward Phase the peripheral may asynchronously assert the nPeriphRequest (nFault) to request that the channel be reversed. When the peripheral is not busy it sets PeriphAck (Busy) low. The host then sets HostClk (nStrobe) low when it is prepared to send data. The data must be stable for the specified setup time prior to the falling edge of HostClk.
The peripheral then sets PeriphAck (Busy) high to acknowledge the handshake. The host then sets HostClk (nStrobe) high. The peripheral then accepts the data and sets PeriphAck (Busy) low, completing the transfer. This sequence is shown in figure 36. The timing is designed to provide 3 cable round-trip times for data setup if Data is driven simultaneously with HostClk (nStrobe). Reverse-Idle Phase The peripheral has no data to send and keeps PeriphClk high. The host is idle and keeps HostAck low. Reverse Data Transfer Phase The interface transfers data and commands from the peripheral to the host using an interlocked HostAck and PeriphClk. The Reverse Data Transfer Phase may be entered from the Reverse-Idle Phase. After the previous byte has beed accepted the host sets HostAck (nALF) low. The peripheral then sets PeriphClk (nACK) low when it has data to send. The data must be stable for the specified setup time prior to the falling edge of PeriphClk. When the host is ready it to accept a byte it sets HostAck (nALF) high to acknowledge the handshake. The peripheral then sets PeriphClk (nACK) high. After the host has accepted the data it sets HostAck (nALF) low, completing the transfer. This sequence is shown in figure 34.
SMSC DS - FDC37N958FR
Page 292
Rev. 09/01/99
Output Drivers To facilitate higher performance data transfer, the use of balanced CMOS active drivers for critical signals (Data, HostAck, HostClk, PeriphAck, PeriphClk) are used ECP Mode. Because the use of active drivers can present compatibility problems in Compatible Mode (the control signals, by tradition, are specified as open-collector), the drivers are dynamically changed from open-collector to totem-pole. The timing for the dynamic driver change is specified
in the IEEE 1284 Extended Capabilities Port Protocol and ISA Interface Standard, Rev. 1.14, July 14, 1996, available from Microsoft. The dynamic driver change must be implemented properly to prevent glitching the outputs.
SMSC DS - FDC37N958FR
Page 293
Rev. 09/01/99
t6 t3 PDATA t1 t2 t5
nSTROBE
t4 BUSY
FIGURE 43 - PARALLEL PORT FIFO TIMING Table 102 - Parallel Port FIFO Timing Parameters
NAME t1 t2 t3 t4 t5 t6 DESCRIPTION DATA Valid to nSTROBE Active nSTROBE Active Pulse Width DATA Hold from nSTROBE Inactive (Note 1) nSTROBE Active to BUSY Active BUSY Inactive to nSTROBE Active BUSY Inactive to PDATA Invalid (Note 1) 680 80 MIN 600 600 450 500 TYP MAX UNITS ns ns ns ns ns ns
Note 1: The data is held until BUSY goes inactive or for time t3, whichever is longer. This only applies if another data transfer is pending. If no other data transfer is pending, the data is held indefinitely.
SMSC DS - FDC37N958FR
Page 294
Rev. 09/01/99
t3 nAUTOFD t4 PDATA<7:0> t2 t1 t7 nSTROBE BUSY t6 t5 t6 t8
FIGURE 44 - ECP PARALLEL PORT FORWARD TIMING Table 103 - ECP Parallel Port Forward Timing Parameters DESCRIPTION MIN TYP MAX nAUTOFD Valid to nSTROBE Asserted PDATA Valid to nSTROBE Asserted BUSY Deasserted to nAUTOFD Changed (Notes 1,2) BUSY Deasserted to PDATA Changed (Notes 1,2) nSTROBE Deasserted to Busy Asserted nSTROBE Deasserted to Busy Deasserted BUSY Deasserted to nSTROBE Asserted 1,2) (Notes 0 0 80 80 0 0 80 80 200 180 60 60 180 180
NAME t1 t2 t3 t4 t5 t6 t7 t8
UNITS ns ns ns ns ns ns ns ns
BUSY Asserted to nSTROBE Deasserted (Note 2)
Note 1: Maximum value only applies if there is data in the FIFO waiting to be written out. Note 2: BUSY is not considered asserted or deasserted until it is stable for a minimum of 75 to 130 ns.
SMSC DS - FDC37N958FR
Page 295
Rev. 09/01/99
t2 PDATA<7:0> t1 t5 nACK t4 nAUTOFD
FIGURE 45 - ECP PARALLEL PORT REVERSE TIMING Table 104 - ECP Parallel Port Reverse Timing DESCRIPTION MIN TYP PDATA Valid to nACK Asserted nAUTOFD Deasserted to PDATA Changed nACK Asserted to nAUTOFD Deasserted (Notes 1,2) nACK Deasserted to nAUTOFD Asserted (Note 2) nAUTOFD Asserted to nACK Asserted nAUTOFD Deasserted to nACK Deasserted 0 0 80 80 0 0 200 200
t6
t3
t4
NAME t1 t2 t3 t4 t5 t6
MAX
UNITS ns ns ns ns ns ns
Note 1: Maximum value only applies if there is room in the FIFO and terminal count has not been received. ECP can stall by keeping nAUTOFD low. Note 2: nACK is not considered asserted or deasserted until it is stable for a minimum of 75 to 130 ns.
SMSC DS - FDC37N958FR
Page 296
Rev. 09/01/99
AB_DATA
tBUF
tLOW
tR
tF
tHD;STA
AB_CLK
tHD;STA
tHD;DAT
tHIGH
tSU;DAT
tSU;STA
tSU;STO
FIGURE 46 - ACCESS.bus TIMING Table 105 - ACCESS.Bus Timing Parameters PARAMETER MIN. TYP. MAX. SCL Clock Frequency Bus Free Time START Condition Set-Up Time START Condition Hold Time SCL LOW Time SCL HIGH Time SCL and SDA Rise Time SCL and SDA Fall Time Data Set-Up Time Data Hold Time STOP Condition Set-Up Time 0.25 0 4.0 4.7 4.7 4.0 4.7 4.0 1.0 0.3 100
SYMBOL fSCL tBUF tSU;STA tHD;STA tLOW tHIGH tR tF tSU;DAT tHD;DAT tSU;STO
UNIT kHz s s s s s s s s s s
SMSC DS - FDC37N958FR
Page 297
Rev. 09/01/99
8051STOPPED SA[15:0] SD[7:0] tsu1 nROM_CS t5 nMEMRD nMEMWR t1 FA[17:16] FA[15:8]
KMEM[2:1] HMEM[1:0]=A[17:16] A[15:0]
t10
t11
D[7:0]
t17
t18
KMEM[2:1]
t2
8051ADR[14:8],KMEM[0]
t4
A[15:8]
t21 t14 t15
A[7:0]
t19
8051ADR[14:8],KM
t2 FAD[7:0] IOCHRDY t3 FALE
8051PORT0
t4
A[7:0]
t8
tsu2
D[7:0]
t21
t19
8051PORT0
t7 t6 t9 nFRD nFWR t12
t13 t16 t20
FIGURE 47 - HOST FLASH READ TIMING
SMSC DS - FDC37N958FR
Page 298
Rev. 09/01/99
Table 106 - Host Flash Read Timing Parameters PARAMETER MIN TYP MAX UNITS t1 8051 stopped condition met to FA[17:16] sourced by 40 ns internal register HMEM[1:0] t2 8051 stopped condition met to FA[15:0] driven by 40 ns SA[15:0] t3 8051 stopped condition met to FALE asserted 40 ns t4 SA[15:0] valid to FA[15:0] valid propogation delay 40 ns t5 SA[15:0] valid to nMEMRD asserted 88 ns t6 nMEMRD asserted to FALE de-asserted 21 63 ns t7 nMEMRD asserted to IOCHRDY de-asserted 24 ns (Note1) t8 FALE de-asserted to FAD[7:0] tristated 42 ns t9 FALE de-asserted to nFRD asserted 84 ns t10 nMEMRD asserted to SD[7:0] driven 30 ns t11 FAD[7:0] data valid to SD[7:0] data valid propogation 40 ns delay ns 200 t12 nFRD, Flash Read, asserted pulse width (Note2) 120 [5 [3 sclk] sclk] t13 nFRD de-asserted to IOCHRDY asserted 0 20 ns t14 FAD[7:0] Data hold time from nFRD de-asserted 0 ns t15 SA[7:0] muxed onto FAD[7:0] following the de42 ns assertion of nFRD t16 nFRD de-asserted to FALE asserted for next cycle 42 ns t17 SD[7:0] data hold time from nMEMRD de-asserted 10 ns t18 8051 clock started condition met to FA[17:16] 40 ns sourced by internal register KMEM[2:1] t19 8051 clock started condition met to FA[15] sourced 40 ns by KMEM[0] and FA[14:0] driven by the 8051 t20 8051 clock started condition met to FALE de40 ns asserted t21 SA[15:0] invalid to FA[15:0] invalid propagation delay 40 ns tsu1 nROM_CS asserted to nMEMRD setup time 20 ns tsu2 FAD[7:0] Data valid to nFRD de-asserted setup time 20 ns Note 1: Systems designed prior to the EISA Specification, R3.12, which sample CHRDY on the rising edge of BCLK require that IOCHRDY is deasserted within 24 ns. Note 2: The Flash Read signal pulse width is programmable through a configuration register, the time values shown are for an internal sclk=24 MHz derived from the 14.318 MHz input.
SMSC DS - FDC37N958FR
Page 299
Rev. 09/01/99
8051STOPPED SA[15:0] SD[7:0] tsu1 nROM_CS nMEMRD t5 nMEMWR t1 FA[17:16] FA[15:8]
KMEM[2:1] HMEM[1:0]=A[17:16] A[15:0]
t16
D[7:0]
t17
t18
KMEM[2:1]
t2
8051ADR[14:8],KMEM[0]
t4
A[15:8]
t21 t13 t14
D[7:0] A[7:0]
t19
8051ADR[14:8],KM
t2 FAD[7:0] IOCHRDY t3 FALE nFRD
8051PORT0
t4
A[7:0]
t9
t21
t19
8051PORT0
t7 t6
t12 t15 t20
t10 nFWR
t11
FIGURE 48 - HOST FLASH WRITE TIMING
SMSC DS - FDC37N958FR
Page 300
Rev. 09/01/99
t1 t2 t3 t4 t5 t6 t7
Table 107 - Host Flash Write Timing Parameters PARAMETER MIN TYP 8051 stopped condition met to FA[17:16] sourced by internal register HMEM[2:1] 8051 stopped condition met to FA[15] driven by SA[15:0] 8051 stopped condition met to FALE asserted SA[15:0] valid to FA[15:0] valid propogation delay SA[15:0] valid to nMEMWR asserted 88 nMEMWR asserted to FALE de-asserted 21 nMEMWR asserted to IOCHRDY de-asserted (Note 1) FALE de-asserted to SD[7:0] driven onto FAD[7:0] FALE de-asserted to nFWR asserted nFWR, Flash Write, asserted pulse width (Note 2)
MAX 40 40 40 40 63 24
UNITS ns ns ns ns ns ns ns
t9 t10 t11
120 [3 sclk]
42 84 200 [5 sclk]
ns ns ns
nFWR de-asserted to IOCHRDY asserted 20 ns FAD[7:0] Data hold time from nFWR de-asserted 42 ns SA[7:0] muxed onto FAD[7:0] following the de42 ns assertion of nFWR t15 nFWR deasserted to FALE asserted for next cycle 42 ns t16 nMEMWR asserted to SD[7:0] valid -10 ns t17 SD[7:0] data hold time from nMEMWR de-asserted 10 ns t18 8051 clock started condition met to FA[17:16] 40 ns sourced by internal register KMEM[2:1] t19 8051 clock started condition met to FA[15] sourced 40 ns by KMEM[0] and FA[14:0] driven by the 8051 t20 8051 clock started condition met to FALE de40 ns asserted t21 SA[15:0] invalid to FA[15:0] invalid propagation delay 40 ns tsu1 nROM_CS asserted to nMEMWR setup time 20 ns Note 1: Systems designed prior to the EISA Specification, R3.12, which sample CHRDY on the rising edge of BCLK require that IOCHRDY is deasserted within 24 ns. Note 2: The Flash Write signal pulse width is programmable through a configuration register, the time values shown are for an internal sclk=24 MHz derived from the 14.318 MHz input.
t12 t13 t14
SMSC DS - FDC37N958FR
Page 301
Rev. 09/01/99
t1 SA[15:0]
t12
t11 AEN t3 t2 nIOR, nIOW t4 nNOWS t7 t8 t5 t9
t6 Read Data
t10 Write Data
FIGURE 49 - ZERO WAIT-STATE (NOWS) TIMING Table 108 - Zero Wait-State Timing Parameters PARAMETER MIN TYP AEN Valid Before nIOR, nIOW Asserted 10 SA[15:0] Valid Before nIOR Asserted 10 nIOR, nIOW Pulse Width 80 nIOR, nIOW Asserted to nNOWS Asserted nIOR, nIOW Negated to nNOWS Floated nIOR Asserted to Read Data Valid nIOR Negated to Read Data Invalid (Hold Time) 0 nIOR Negated to Data Bus Floated Write Data Valid Before nIOW Deasserted 45 nIOW Negated to Write Data Invalid (Hold Time) 0 nIOR, nIOW Negated to AEN Invalid 10 nIOR, nIOW Negated to SA[15:0] Invalid 10
MAX
t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12
50 35 50 24
UNITS ns ns ns ns ns ns ns ns ns ns ns ns
SMSC DS - FDC37N958FR
Page 302
Rev. 09/01/99
t1 t2 FALE t5 FRD t3 t7 t4 FAD[7:0] FA[17:8] FA[7:0] FA[17:8] INS t8 t9 FA[7:0] FA[17:8] t6
FIGURE 50 - 8051 FLASH PROGRAM FETCH TIMING Table 109 - 8051 Flash Program Fetch Timing Parameters OSCILLATOR PARAMETER MIN TYP MAX EQUATION FALE Pulse Width 127 2T-40 Address Valid to FALE Low 43 T-40 nFRD Low to Address Float 10 10 FALE Low to Valid Instruction In 234 4T-100 FALE Low to nFRD Low 53 T-30 nFRD Pulse Width 205 3T-45 nFRD Low to Valid Instruction In 145 3T-105 0 0 Valid Instruction Hold Time Following nFRD Low-To-High Transition Instruction Float Following nFRD 59 T-25 Low-To-High Transition
t1 t2 t3 t4 t5 t6 t7 t8
UNITS ns ns ns ns ns ns ns ns
t9
ns
Min and Max delays shown for an 8051 clock of 12 MHz, to calculate timing delays for other clock frequencies use the Oscillator Equations, where T=1/Fclk.
SMSC DS - FDC37N958FR
Page 303
Rev. 09/01/99
t1 FALE t3 nFRD t7 FAD[7:0] FA[17:8] t2 FA[7:0] FA[17:8] t6 DATA IN t4
t5
t8 FA[7:0 FA[17:8]
FIGURE 51 - 8051 FLASH READ TIMING Table 110 - Flash Read Timing Parameters OSCILLATOR PARAMETER MIN TYP MAX EQUATION Address Valid to FALE Low 43 T-40 Address Hold Following FALE 53 T-30 Low FALE Low to nFRD Low 200 300 3T-50 / 3T+50 nFRD Pulse Width 400 6T-100 nFRD High to FALE High 43 123 T-40 / T+40 nFRD Low to Valid Data In 252 5T-165 Data Hold Following nFRD 0 0 Data Float Following nFRD 107 2T-60
t1 t2 t3 t4 t5 t6 t7 t8
UNITS ns ns ns ns ns ns ns ns
Min and Max delays shown for an 8051 clock of 12 MHz, to calculate timing delays for other clock frequencies use the Oscillator Equations, where T=1/Fclk.
SMSC DS - FDC37N958FR
Page 304
Rev. 09/01/99
t1 FALE t3 t6 nFWR t2 FAD[7:0] FA[17:8] FA[7:0] DATA OUT FA[17:8] t4
t5
t7 FA[7:0] FA[17:8]
FIGURE 52 - 8051 FLASH WRITE TIMING Table 111 - Flash Write Timing Parameters OSCILLATOR PARAMETER MIN TYP MAX EQUATION Address Valid to FALE Low 43 T-40 Address Hold Following FALE 53 T-30 Low FALE Low to nFWR Low 200 300 3T-50 / 3T+50 nFWR Pulse Width 400 6T-100 nFWR High to FALE High 43 123 T-40 / T+40 Data Valid to nFWR Falling Edge 33 T-50 Data Hold Following nFWR 33 T-50
t1 t2 t3 t4 t5 t6 t7
UNITS ns ns ns ns ns ns ns
Min and Max delays shown for an 8051 clock of 12MHz, to calculate timing delays for other clock frequencies use the Oscillator Equations, where T=1/Fclk.
SMSC DS - FDC37N958FR
Page 305
Rev. 09/01/99
MIN A A1 A2 D D1 E E1 H L Notes: 1) 2) 3) 4) 0.05 3.17 30.35 27.90 30.35 27.90 0.09 0.35
NO M
30.60 28.00 30.60 28.00 0.50
MAX 4.07 0.5 3.67 30.85 28.10 30.85 28.10 0.230 0.65
MIN L1 e 0 W R1 R2
NO M 1.30 0.50BSC
MAX
0 0.10 0.20 or 0.15 0.30 or 0.20
7 0.30
Coplanarity is 0.080 mm maximum Tolerance on the position of the leads is 0.080 mm maximum Package body dimensions D1 and E1 do not include the mold protrusion. Maximum mold protrusion is 0.25 mm Dimensions for foot length L when measured at the centerline of the leads are given at the table. Dimension for foot length L when measured at the gauge plane 0.25 mm above the seating plane, is 0.6 mm Details of pin 1 identifier are optional but must be located within the zone indicated Controlling dimension: millimeter
5) 6)
FIGURE 53 - 208 PIN QFP PACKAGE OUTLINE
SMSC DS - FDC37N958FR
Page 306
Rev. 09/01/99
M IN A A1 A2 D D1 E E1 H N o te s : 1) 2) 3) 4) 5) 6) 0 .0 5 1 .3 5 29 .9 0 27 .9 0 29 .9 0 27 .9 0 0 .0 9
NOM
30 .0 0 28 .0 0 30 .0 0 28 .0 0
M AX 1 .6 0 .1 5 1 .4 5 30 .1 0 28 .1 0 30 .1 0 28 .1 0 0.2 3 0
L L1 e 0 W R1 R2 ccc
M IN 0.45
NOM 0 .6 0 1 .0 0 0 .5 0B S C
M AX 0.7 5
0 0.17 0.08 0.08
7 0.2 7 0.2 0 0.0 8
C o pla n arity is 0.0 8 0 m m o r 3.2 m ils m ax im u m Tole ra n c e on the po s itio n o f th e le ad s is 0 .0 80 m m m a x im um Pa ck a g e b o dy d im e n s io n s D 1 an d E 1 d o n o t in c lu d e th e m o ld p rotru s io n. M a x im u m m o ld p ro tru s io n is 0 .25 m m D im e n s io ns for fo o t len g th L m e as ured a t the ga u g e p lan e 0 .2 5 m m a b o ve th e s ea tin g p la ne D e ta ils o f p in 1 id en tifier a re op tio n al but m u s t b e lo c a ted w ith in th e z o n e ind ic a ted C o ntrollin g d im en s io n : m illim ete r
FIGURE 54 - 208 PIN TQFP PACKAGE OUTLINE
SMSC DS - FDC37N958FR
Page 307
Rev. 09/01/99
FUNCTIONAL REVISION ADDENDUM
SEE DATASHEET PAGES 138, 139, 141,142, 189, 241, 244, 246 1. 2.
FUNCTIONAL REVISION B&C
DEVICE REVISION REG VALUE 01h
DESCRIPTION Device Reg value = 01h Led Reg is powered by VCC1. The data contents remains undefined until VCC2 POR. Device Reg value = 08 Led Reg is powered by VCC1. When VCC1 POR the data contents default is accessible. VCC2 POR has no impact on this register.
D
08h
138, 139, 141,142, 189, 241, 244, 246
1. 2.
SMSC DS - FDC37N958FR
Page 308
Rev. 09/01/99
FDC37N958FR ERRATA SHEET
DATE REVISED 9/1/99 9/1/99 9/1/99 9/1/99 9/1/99 9/1/99 9/1/99 9/1/99 9/1/99 9/1/99 9/1/99
PAGE 138 139 141 142 142 189 189 241 244 246 308
SECTION/FIGURE/ENTRY Table 56 Table 56 Note 13 added Device Rev Register Device Rev Register LED Register Note 2 added Table 77 Note 4 added Table 78 Functional Revision Addendum
CORRECTION See italicized text See italicized text See italicized text 01h changed to see note Note added 0x00 changed to see note 2 See italicized text See italicized text See italicized text See italicized text New page
SMSC DS - FDC37N958FR
Page 309
Rev. 09/01/99
(c) 1999 STANDARD MICROSYSTEMS CORPORATION (SMSC)
Circuit diagrams utilizing SMSC products are included as a means of illustrating typical applications; consequently complete information sufficient for construction purposes is not necessarily given. The information has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies. Furthermore, such information does not convey to the purchaser of the semiconductor devices described any licenses under the patent rights of SMSC or others. SMSC reserves the right to make changes at any time in order to improve design and supply the best product possible. SMSC products are not designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. FDC37N958FR Rev. 9/01/99


▲Up To Search▲   

 
Price & Availability of FDC37N958FR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X